VM600 CPU M 200-595-065-114/200-595-100-013
VM600 CPU M 200-595-065-114/200-595-100-013
VM600 CPU M 200-595-065-114/200-595-100-013
VM600 CPU M 200-595-065-114/200-595-100-013
VM600 CPU M 200-595-065-114/200-595-100-013
VM600 CPU M 200-595-065-114/200-595-100-013
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports paired-card identification, revision review and quotation preparation for this VM600 rack assembly.

VM600 CPU M 200-595-065-114/200-595-100-013

/ 4.9
1001 reviews | Need a Specific Revision?
Vibro-Meter VM600 CPU M 200-595-065-114/200-595-100-013 is a CPUM and IOCN card set that provides processing and communication functions for a VM600 rack.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for VM600 CPU M 200-595-065-114/200-595-100-013
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for VM600 CPU M 200-595-065-114/200-595-100-013

  • Manufacturer:
    Vibro-Meter
  • Part Number:
    VM600 CPU M 200-595-065-114/200-595-100-013
  • Product Family:
    Vibro-Meter
  • Product Type:
    VM600 CPUM and IOCN Card Set
  • Stock:
    1
  • Product Platform:
    Vibro-Meter VM600
  • Card Set:
    CPUM processor card and IOCN input/output card
  • Processor:
    500 MHz
  • Memory:
    256 MB DRAM
  • Operating System:
    QNX real-time operating system
  • Communication:
    Ethernet and serial interfaces, configuration dependent
  • Order References:
    200-595-065-114 / 200-595-100-013
  • Weight:
    0.5 kg
  • Estimated shipping dimensions:
    26x18.7x4cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Pairing & Identity Rack Communications Configuration Recovery Product Applications

Features:

  • Rack processing: Provides CPU and communications functions for a compatible VM600 rack
  • Paired identity: Retains both order references as one service and receiving record
  • Configuration control: Depends on firmware, interface routing and network settings from the installed system
The paired cards coordinate rack processing with external Ethernet or serial communication and the internal VME backplane.

Hardware and firmware revisions affect interface capability, so the complete labels and configuration evidence must remain linked.

A controlled replacement includes backup, physical matching, rack-health checks and proof of every communication path used by the project.

Apter Power supports Vibro-Meter VM600 CPU M 200-595-065-114/200-595-100-013 CPUM and IOCN Card Set sourcing with configuration review.
Vibro-Meter VM600 CPU M 200-595-065-114/200-595-100-013 CPUM and IOCN Card Set Manuals,Datasheets,Link Important Notice: Retain both identifiers and back up firmware, interface routing and network settings before service.
  • Two-part record: Keeps both supplied references together for quotation, receiving and maintenance.
  • Revision evidence: Firmware and hardware markings must be captured from the actual cards.
  • Rack position: Record front and rear card placement and the connectors used by the installation.
  • Compatibility boundary: Do not infer interchangeability from the VM600 CPU M family name alone.
  • Backplane path: Communicates with compatible protection cards through the VM600 rack architecture.
  • Ethernet services: Supports configured network communication through the available front or rear interfaces.
  • Serial services: Uses enabled RS interfaces according to card version and jumper routing.
  • Time reference: Rack behavior may depend on the configured network or internal time source.
  • Pre-service backup: Save configuration files, firmware details and network or serial parameters.
  • Routing record: Document jumpers, connector assignments and plant cable destinations.
  • Controlled startup: Check card recognition, diagnostics and security state after installation.
  • End-to-end proof: Validate every monitoring, engineering and plant communication path in use.
  • VM600 rack management: Coordinates processing and communication within installed VM600 systems.
  • Machinery protection support: Exchanges data with compatible protection cards over the rack backplane.
  • Plant communications: Provides configured Ethernet or serial paths to external systems.
  • Planned card-pair service: Supports controlled replacement where complete configuration records exist.
Description
VM600 CPU M 200-595-065-114/200-595-100-013 is recorded as a paired processor and connection-card assembly for a Vibro-Meter VM600 rack. The set supports rack-level processing and the communication paths used by compatible machinery-protection and condition-monitoring cards.

Ethernet, serial and backplane communication make VM600 CPU M 200-595-065-114/200-595-100-013 part of the rack infrastructure rather than a standalone controller. Firmware, hardware revision and interface routing determine how the cards interact with the installed VM600 configuration.

Service work on VM600 CPU M 200-595-065-114/200-595-100-013 should preserve both identifiers, the rack slot record, firmware information and network settings. Commissioning then confirms card recognition, time synchronization, communication with protection cards and every enabled plant data path.
Alternative Names
VM600 CPU M VM600 CPUM 200-595-065-114 200-595-100-013 VM600 CPU M 200-595-065-114 200-595-100-013
Technical notes
VM600 CPU M 200-595-065-114/200-595-100-013 should be treated as a configuration-controlled rack pair. Save firmware, network and serial settings, interface routing and slot records before removal. After installation, verify backplane communication, time synchronization, security state and each configured plant interface before relying on the rack for protection or monitoring.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why should both identifiers remain on an RFQ for VM600 CPU M 200-595-065-114/200-595-100-013?
The two references identify the supplied processor and connection-card set. Keeping both prevents the assembly from being reduced to a generic CPU M family description.
Can one card be changed without reviewing VM600 CPU M 200-595-065-114/200-595-100-013 as a pair?
Only when an approved compatibility procedure confirms the hardware revision, firmware and interface role of the remaining card.
What should be backed up before replacing VM600 CPU M 200-595-065-114/200-595-100-013?
Save the firmware and hardware versions, configuration files, network and serial settings, time source, security state, slot positions and cable destinations.
Which startup checks are essential for VM600 CPU M 200-595-065-114/200-595-100-013?
Confirm card recognition, rack diagnostics, backplane communication, time synchronization and every configured Ethernet or serial connection before relying on the rack.
How can communication loss on VM600 CPU M 200-595-065-114/200-595-100-013 be diagnosed?
Use rack diagnostics and port status to test the backplane, Ethernet and serial paths separately, then compare the failed path with its cable routing and configured interface.
Why can time-dependent data differ after VM600 CPU M 200-595-065-114/200-595-100-013 service?
The rack may not have regained its configured time source or synchronization path. Confirm the active reference and compare timestamps before accepting monitoring data.