VM600 RPS6U SIM-330A 200-582-500-021
VM600 RPS6U SIM-330A 200-582-500-021
VM600 RPS6U SIM-330A 200-582-500-021
VM600 RPS6U SIM-330A 200-582-500-021
VM600 RPS6U SIM-330A 200-582-500-021
VM600 RPS6U SIM-330A 200-582-500-021
VM600 RPS6U SIM-330A 200-582-500-021
VM600 RPS6U SIM-330A 200-582-500-021
VM600 RPS6U SIM-330A 200-582-500-021
VM600 RPS6U SIM-330A 200-582-500-021
VM600 RPS6U SIM-330A 200-582-500-021
VM600 RPS6U SIM-330A 200-582-500-021
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports rack-load review, condition evidence, documentation, quotation coordination, and pre-shipment checks.

VM600 RPS6U SIM-330A 200-582-500-021

/ 4.9
1001 reviews | Need a Specific Revision?
Vibro-Meter VM600 RPS6U SIM-330A 200-582-500-021 is a 330 W AC-input rack power supply for first-generation VM600 ABE04x monitoring racks.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for VM600 RPS6U SIM-330A 200-582-500-021
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for VM600 RPS6U SIM-330A 200-582-500-021

  • Manufacturer:
    Vibro-Meter
  • Part Number:
    VM600 RPS6U SIM-330A 200-582-500-021
  • Product Family:
    Vibro-Meter
  • Product Type:
    VM600 RPS6U 330 W Rack Power Supply
  • Stock:
    1
  • RPS6U version:
    VM600 AC-input, 330 W
  • Ordering family:
    200-582-500-02h
  • Nominal input:
    115/230 V AC or 220 V DC
  • AC input range:
    90 to 132 V AC and 180 to 264 V AC
  • DC input range:
    178 to 264 V DC with appropriate rear panel
  • Output rails:
    +5 V up to 50 A; +12 V up to 8 A; -12 V up to 4 A
  • Combined output power:
    330 W maximum
  • Operating temperature:
    0 to 70 °C
  • Rack position PS1:
    Slots 18 to 20
  • Optional rack position PS2:
    Slots 15 to 17
  • Weight:
    2.4 kg
  • Estimated shipping dimensions:
    6.06 x 19 x 26.17 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Input & Outputs Protection & Derating Rack Integration Product Applications

Features:

  • Full-rack power: one 330 W supply supports a complete VM600 rack up to 50 °C.
  • Three output rails: +5 V and ±12 V feed the backplane and installed cards.
  • Flexible resilience: a second RPS6U can provide redundancy or extra derated capacity.
Select this RPS6U when the installed ABE04x rack uses the AC-input 200-582-500-02h hardware family.

Confirm the rack rear panel and PS1 or PS2 position before ordering, especially when a DC source is used with the AC version.

The installed-card load and availability target determine whether the rack needs one supply, two redundant supplies or two units sharing a higher derated demand.
Apter Power can review VM600 RPS6U SIM-330A 200-582-500-021 rack load, rear-panel interface, condition, and quotation scope.
Vibro-Meter VM600 RPS6U SIM-330A 200-582-500-021 VM600 RPS6U 330 W Rack Power Supply Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • AC input: autoranging operation covers 90-132 V AC and 180-264 V AC.
  • DC operation: the AC version accepts 178-264 V DC with an appropriate rear panel.
  • Backplane rails: outputs are +5 V, +12 V and -12 V DC.
  • Power ceiling: all three rails share a 330 W combined maximum.
  • Overvoltage: the supply latches off and requires input-power recycling after the cause is removed.
  • Short circuit: automatic recovery follows removal of the short.
  • Overload: automatic recovery follows removal of the excessive load.
  • Temperature: natural-cooling output derating applies above the specified thresholds.
  • Primary position: PS1 occupies rack slots 18 to 20.
  • Second position: optional PS2 occupies slots 15 to 17.
  • Redundant mode: either supply can carry the full rack load up to 50 °C.
  • High-temperature mode: two non-redundant supplies can share derated rack demand.
  • VM600 machinery protection: power monitoring cards used for turbine, compressor or generator protection.
  • Condition-monitoring racks: feed a full ABE04x rack from one 330 W RPS6U under the stated temperature limit.
  • High-availability monitoring: install two supplies where rack power redundancy is required.
Description
Powering the backplane and installed monitoring cards, VM600 RPS6U SIM-330A 200-582-500-021 is the 330 W AC-input supply for first-generation VM600 ABE04x 6U racks. It supports standard AC feeds and an approved DC-input arrangement through the appropriate rack rear panel.

Regulated +5 V and ±12 V outputs allow one VM600 RPS6U SIM-330A 200-582-500-021 to serve the different power needs of a populated monitoring rack. Overvoltage latch-off and automatic recovery from short-circuit or overload conditions protect the rack supply path and simplify fault recovery.

A rack can use one VM600 RPS6U SIM-330A 200-582-500-021 for normal operation or a second unit for redundancy or additional derated capacity. The 200-582-500-02h hardware family keeps minor final-digit revisions interchangeable within this version, supporting controlled maintenance without treating different input versions as equivalent.
Alternative Names
RPS6U SIM-330A 200-582-500-021 200-582-500-021 VM600 RPS6U AC 330 W SIM-330A 200-582-500-021 VM600 RPS6U SIM-330A-200-582-500-021
Technical notes
VM600 RPS6U SIM-330A 200-582-500-021 has a 330 W combined output limit; the +5 V and ±12 V rails cannot all run at their individual maxima simultaneously. At elevated temperature, calculate rack-card demand and derating before choosing one supply, redundant two-supply operation, or two non-redundant supplies for additional capacity.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What does VM600 RPS6U SIM-330A 200-582-500-021 power?
It supplies +5 V and ±12 V through the VM600 ABE04x rack backplane to the rack and its installed monitoring cards.
Can VM600 RPS6U SIM-330A 200-582-500-021 use a 220 V DC source?
Yes. This AC-input version accepts 178 to 264 V DC when paired with an appropriate VM600 rear panel that provides the DC input path.
Why is the 330 W limit important for VM600 RPS6U SIM-330A 200-582-500-021?
It is the combined limit for all outputs. If +5 V supplies 267.5 W at 50 A, the two 12 V rails together can use no more than 62.5 W.
When are two VM600 RPS6U SIM-330A 200-582-500-021 supplies redundant?
They are redundant when either unit can carry the full rack demand. At up to 50 °C, loss of one supply should leave the other able to provide 100% of the required power.
How does high temperature affect VM600 RPS6U SIM-330A 200-582-500-021 planning?
With natural cooling, +5 V output derates above 50 °C and the ±12 V outputs derate above 55 °C. Recalculate the installed-card load before selecting the supply arrangement.
What should be checked before replacing VM600 RPS6U SIM-330A 200-582-500-021?
Confirm the 200-582-500-021 label, AC-input version, 330 W generation, rack rear panel, PS1 or PS2 position, card-load calculation, temperature and redundancy objective.