ARM55D-000

/ 4.9
1001 reviews | Need a Specific Revision?
Yokogawa ARM55D-000 is a rack-mounted 32-point mechanical relay board for normally open dry-contact outputs for CENTUM VP FIO Relay Boards.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for ARM55D-000
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ARM55D-000

  • Manufacturer:
    Yokogawa
  • Part Number:
    ARM55D-000
  • Product Family:
    Centum CS-Centum VP
  • Product Type:
    Mechanical Relay Board (32 Dry Contact Outputs)
  • Stock:
    1
  • Signal Service:
    Mechanical relay dry-contact output, normally open
  • Contact Points:
    32 points
  • Terminal Hardware:
    M4 screws
  • Connectable Modules:
    ADV551 with ATD5A; ADV561
  • Signal Cables:
    AKB331 for 32-point; AKB337 for 64-point
  • Ordering Code:
    -000: 19-inch rack mountable, basic type
  • Maximum Load at 250 V AC:
    2 A per point
  • Maximum Load at 30 V DC:
    2 A per point
  • Maximum Load at 125 V DC:
    0.1 A per point
  • Minimum Load:
    5 V, 10 mA
  • Internal Circuit Supply:
    24 V DC, maximum 0.65 A
  • Insulation Resistance:
    At least 10 megohm at 500 V DC
  • Ambient Temperature:
    0 to 50 C
  • Relative Humidity:
    10 to 90% RH
  • Official Options:
    /BR3 wall mount bracket; /NTRY without cable tray
  • Weight:
    2 kg
  • Estimated shipping dimensions:
    48.26 x 13.25 x 8.5 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Dry Outputs Load Review Module Matching

Features:

  • Normally open dry outputs: Thirty-two M4-terminal points provide the official contact-output arrangement.
  • Documented load limits: AC and DC ratings must be matched to the actual field load.
  • FIO output paths: Use ADV551 with ATD5A or the documented ADV561 interface.

ARM55D-000 is the basic rack-mounted dry-contact output relay board in the Yokogawa FIO family.

The load table distinguishes 250 V AC, 30 V DC, and 125 V DC limits and requires protection for inductive loads.

Procurement should verify the -000 code, field load, module path, signal cable, M4 termination, and cabinet layout.

Availability is subject to Apter Power's current inventory and sourcing confirmation.

Yokogawa ARM55D-000 Mechanical Relay Board (32 Dry Contact Outputs) Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Yokogawa ARM55D-000 Mechanical Relay Board (32 Dry Contact Outputs) Specs

General

  • ManufacturerYokogawa
  • ModelARM55D-000
  • ConditionNew and factory sealed
  • Product FamilyCENTUM VP FIO Relay Boards

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Normally open contact checks

  • Point count: Confirm all 32 output assignments.
  • Contact form: Use the documented normally open dry-contact scope.
  • Minimum load: Retain the 5 V, 10 mA boundary.
  • Testing: Commission each output against the field schedule.

Field-load verification

  • AC load: Check the 250 V AC, 2 A per-point limit.
  • Low-voltage DC: Check the 30 V DC, 2 A per-point limit.
  • 125 V DC: Observe the 0.1 A per-point limit.
  • Inductive loads: Apply the official protection-circuit guidance.

Output interface review

  • ADV551 path: Confirm ATD5A and AKB331.
  • ADV561 path: Confirm AKB337 and the documented board count.
  • Internal supply: Provide 24 V DC within 0.65 A.
  • Mounting: Verify rack -000 versus /BR3.
Description

The Yokogawa ARM55D-000 is a rack-mounted 32-point mechanical relay board for normally open dry-contact outputs in the CENTUM VP FIO Relay Boards family.

Official documentation for ARM55D-000 confirms this configuration. It receives digital output module signals through ADV551 with ATD5A or ADV561 and presents M4 field terminals.

Before ordering ARM55D-000, verify the -000 rack configuration, dry-contact load, module path, signal cable, and inductive-load protection.

Alternative Names
Yokogawa ARM55D-000 ARM55D-000 ARM55D ARM55D 000 ARM55D000 ARM55D-000 Mechanical Relay Board (32 Dry Contact Outputs) ARM55D-000 CENTUM VP ARM55D CENTUM VP FIO Relay Boards
Technical notes
ARM55D-000 is a rack-mounted 32-point mechanical relay board for normally open dry-contact outputs. Confirm the complete suffix, connected hardware, and documented field interface before procurement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is ARM55D-000 used for?
It provides 32 normally open dry-contact outputs for the documented Yokogawa FIO output-module paths.
Which load ratings matter for ARM55D-000?
Check the official per-point rating for the actual AC or DC voltage and add protection for inductive loads.
Which modules are documented for ARM55D-000?
Yokogawa lists ADV551 with ATD5A and ADV561, using AKB331 or AKB337 as applicable.
How should ARM55D-000 be verified before ordering?
Compare the full code, M4 terminals, load schedule, module, signal cable, rack mounting, and nameplate.
Can ARM55C-000 be treated as the same output board?
No. ARM55C supports selectable NO or NC contacts and has different terminals and load data.
Where can procurement download the ARM55D-000 datasheet?
Open the first Manuals link for the verified data reference.
How can I request ARM55D-000 price and lead time?
Send the complete code, field-load details, module path, cable, quantity, destination, and required date.