AAI141-S00

/ 4.9
1001 reviews | Need a Specific Revision?
AAI141-S00 is a Yokogawa 16-channel analog input module for 4-20 mA signals, non-isolated, compatible with pressure clamp terminals or terminal boards via KS cable adapters.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for AAI141-S00
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for AAI141-S00

  • Manufacturer:
    Yokogawa
  • Part Number:
    AAI141-S00
  • Product Family:
    Yokogawa DCS system
  • Product Type:
    16-Channel Analog Input Module
  • Stock:
    1
  • Number of Channels:
    16
  • Input Signal:
    4 to 20 mA
  • Isolation:
    Non-isolated
  • Recommended Cable Thickness:
    0.5 to 2 mm² (AWG 20-14)
  • Peel-off Length (without sleeve):
    11 mm
  • Sleeve Standard (with cover):
    DIN 46228/4
  • 2-Wire Transmitter:
    Supported (power supply from module)
  • Open State on Power Loss:
    Current input loop open
  • Terminal Labeling:
    IN1-A1/B1 to IN16-A16/B16
  • Weight:
    0.28 kg
  • Estimated shipping dimensions:
    3.3x10.7x13cm
  • Tariff Code:
    8517795000
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Application Diagnosis and Protection Upgrade Guide

Features:

  • AAI141-S00 provides 16 non-isolated 4-20 mA input channels with pressure clamp terminal connections.
  • Supports 2-wire transmitters with internal power or 4-wire transmitters requiring external power supply.
  • Compatible with ATA4S single or ATA4D dual-redundant terminal blocks for flexible system configuration.
The AAI141-S00 delivers 16 analog input channels in a single module, providing high-density signal acquisition for Yokogawa CENTUM VP and Stardom FIO systems. Each channel accepts standard 4-20 mA signals from field transmitters measuring pressure, temperature, level, or flow. The module uses pressure clamp terminals on ATA4S (single configuration) or ATA4D (dual-redundant configuration) terminal blocks, eliminating the need for screw-type terminations that can loosen over time. Pressure clamp terminals provide secure, vibration-resistant connections and reduce installation time. Recommended cable thickness is 0.5 to 2 mm² (AWG 20-14), with a peel-off length of 11mm without sleeve or 12mm with sleeve.

The AAI141-S00 supports both 2-wire and 4-wire transmitter connections, providing flexibility for various field device types. For 2-wire transmitters, the module provides loop power directly through the input channel, eliminating the need for external power supplies. This simplifies wiring and reduces panel space. For 4-wire transmitters, the module accepts a 4-20 mA signal from externally powered devices, requiring the user to provide separate field power. The input type is selected via setting pins on the associated terminal block or adapter.

The AAI141-S00 offers three distinct connection methods to accommodate different installation requirements. First, direct pressure clamp terminal connection using ATA4S (single) or ATA4D (dual-redundant) terminal blocks, ideal for standard panel installations. Second, terminal board connection using KS cable adapter ATK4A and KS1A cable to AEA4D terminal board, allowing remote mounting of field wiring from the I/O module.

The AAI141-S00 YOKOGAWA 16-Channel Analog Input Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).

YOKOGAWA AAI141-S00 16-Channel Analog Input Module Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
YOKOGAWA AAI141-S00 16-Channel Analog Input Module Specs

General

  • Manufacturer YOKOGAWA
  • Model AAI141-S00
  • Condition New Original ready stock
  • Product Family AAI143-S00 S1,AAI143-S50 S1,AAI143-S53 S1
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Oil & Gas: Upstream crude oil extraction, long-distance pipeline monitoring, and oil refinery process control.
  • Chemical & Petrochemical: Reactor temperature acquisition, pressure pipeline monitoring, and precise chemical flow metering.
  • Power & Energy: Boiler drum level control in thermal power plants, turbine monitoring, and utility water system control.
  • Water Treatment: Inlet/outlet flow rate, pH value, and turbidity data collection in water supply and wastewater treatment plants.
  • Overcurrent Protection: The internal current-limiting design allows a maximum input current of 27 mA. If a field transmitter faults and outputs excessive current, the module limits it automatically to prevent burning the internal sampling resistors.
  • Flexible 2/4-Wire Configuration: Each channel can be independently configured via hardware setting pins for 2-wire (module-powered) or 4-wire (externally powered) loops, preventing power conflicts and hardware damage.
  • Dual-Redundant Switching: Two AAI141 modules can be installed in adjacent slots to form a dual-redundant pair. If the active module fails, the system switches to the standby module within microseconds without disturbing the process.
  • Self-Diagnostics: The system continuously monitors the status of the A/D converter, microprocessor, internal voltage, and communication bus. When an anomaly occurs, the FAIL LED lights up, and a system alarm triggers on the DCS Human Interface Station (HIS).
  • Hot-Swapping: The module supports hot-swapping while the node unit (such as ANB10) is powered. Ensure the redundant module is healthy or the control loop is switched to manual/safe mode before replacement.
  • External Wiring Interface: The front interface connects to standard Yokogawa terminal boards (e.g., ATA4S, ATA4D) using dedicated KS signal cables (e.g., KS1).
  • Loop Resistance Matching: For dual-redundant configurations, the loop resistance of the signal cables must be strictly identical to maintain signal measurement accuracy.
  • Current State: The -S00 model is a standard type and does not support HART protocol communication.
Description
The AAI141-S00 is a 16-channel analog input module designed for Yokogawa CENTUM VP and Stardom FIO systems, accepting 4-20 mA signals from field transmitters. This non-isolated module supports both 2-wire and 4-wire transmitter connections, with terminal blocks ATA4S (single) or ATA4D (dual-redundant) available.

For 2-wire transmitter input, the AAI141-S00 provides transmitter power supply directly through the module. For 4-wire transmitter input, an external power source is required. When the AAI141-S00 power is off or abnormal, the current input loop is in an open state. 

The AAI141-S00 is part of a comprehensive I/O solution that includes analog input, analog output, and digital I/O modules. The AAI141-S00 pairs with ATA4S (single) or ATA4D (dual-redundant) terminal blocks, and can also connect via MIL cable directly to the module.

For signal wiring, the AAI141-S00 supports cable termination with or without sleeves. When using sleeves, it is recommended to use DIN 46228/1 (without insulating cover) or DIN 46228/4 (with insulating cover) sleeves.
Alternative Names
AAI141-SOO AAII4I-S00 AAI141 S00 AAI141-S00 S2 AAI141-H00 S1 AAI141-H03 S1 AAI143-H00 S1 AAI143-S00 S1
Technical notes
The AAI141-S00 is a 16-channel 4-20 mA analog input module for Yokogawa FIO systems. Non-isolated design supports 2-wire (internal power) or 4-wire (external power) transmitters. Uses ATA4S (single) or ATA4D (redundant) pressure clamp terminals.Compatible with ATK4A KS cable adapter and AEA4D terminal board.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How many channels does AAI141-S00 have?
AAI141-S00 provides 16 analog input channels for 4-20 mA signals. Channels are labeled IN1 through IN16 on terminals A1-B1 through A16-B16.
Is AAI141-S00 isolated?
No, AAI141-S00 is non-isolated. For isolated 4-20 mA input applications, refer to Yokogawa's AAI143 module instead.
What terminal blocks work with AAI141-S00?
AAI141-S00 uses ATA4S for single configuration or ATA4D for dual-redundant configuration with pressure clamp terminals.
What happens to AAI141-S00 on power loss?
When AAI141-S00 power is off or abnormal, the current input loop enters an open state. Do not use with other receiving devices without external shunt resistance.