Features:
- The NF2-approved low-span F-capsule configuration uses the 0.5 to 5 kPa (2 to 20 inH2O) capsule, horizontal piping with left-side high pressure and 1/2 NPT female, two entries without blind plug.
- The NF2-approved low-span F-capsule configuration provides 4–20 mA DC with digital communication through HART 5/HART 7 protocol, with digital indicator.
- The NF2-approved low-span F-capsule configuration combines 1/2 NPT female process connectors, S-code wetted assembly with Hastelloy C-276 diaphragm and 304 SST flat 2-inch pipe bracket.
The supplied EJA110E-JFS4J-912DB/NF2 variant is distinguished by F-capsule low-span configuration and open electrical entry arrangement.
It measures differential and static pressure for engineered flow, level, density or equipment-monitoring duties, with remote access through HART 5/HART 7 protocol.
Match F capsule, terminal-entry plug arrangement or NF2 approval to the existing assembly before wiring, pressurization or actuator movement.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Yokogawa EJA110E-JFS4J-912DB/NF2:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- The NF2-approved low-span F-capsule configuration measures differential pressure across a primary flow element, filter, heat exchanger or vessel connection.
- The NF2-approved low-span F-capsule configuration supports inferred flow, level or density calculations when the impulse-piping and manifold design are validated.
- The NF2-approved low-span F-capsule configuration provides differential and static-pressure information for process control, protection or condition monitoring.
- For operating environment, the enclosure is intended for indoor or outdoor industrial use within -40 to 85°C (-40 to 185°F), or -30 to 80°C with LCD under pollution degree 2 conditions.
- Process exposure must remain compatible with S-code wetted assembly with Hastelloy C-276 diaphragm and the selected fill-fluid requirements.
- Vibration, impulse-line support and the horizontal piping with left-side high pressure position must remain within the official mounting guidance.
- Isolation and depressurization are required before disturbing the 1/2 NPT female process connections.
- Wetted-material compatibility must be confirmed for S-code wetted assembly with Hastelloy C-276 diaphragm to prevent leakage or diaphragm damage.
- The /NF2 suffix specifies NEPSI Ex ia IIC T4 Ga intrinsic-safety approval for HART/BRAIN protocol types. It also governs the applicable entity parameters and temperature limits.
- The selected capsule has a calibrated span of 0.5 to 5 kPa (2 to 20 inH2O) and an allowable configurable range of -5 to 5 kPa.
- Zero may be elevated or suppressed only while both range endpoints remain inside the official capsule limits.
- Range selection must consider expected pressure, overpressure, process temperature and the horizontal piping with left-side high pressure zero shift.