    The exact EJA110E-JFS4J-912DB/NF2 configuration remains subject to nameplate and sourcing verification.

EJA110E-JFS4J-912DB/NF2

/ 4.9
1001 reviews | Need a Specific Revision?
Yokogawa EJA110E-JFS4J-912DB/NF2 is an F-capsule low-span differential-pressure configuration with NF2 intrinsic-safety approval for differential-pressure, flow, level or density measurement.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for EJA110E-JFS4J-912DB/NF2
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for EJA110E-JFS4J-912DB/NF2

  • Manufacturer:
    Yokogawa
  • Part Number:
    EJA110E-JFS4J-912DB/NF2
  • Product Family:
    Yokogawa DCS system
  • Product Type:
    Differential Pressure Transmitter
  • Stock:
    1
  • Measurement / Function:
    differential pressure and static pressure
  • Output / Command Signal:
    4–20 mA DC with digital communication
  • Communication / Control Interface:
    HART 5/HART 7 protocol
  • Selected Span / Torque Class:
    0.5 to 5 kPa (2 to 20 inH2O)
  • Configurable Range / Travel:
    -5 to 5 kPa
  • Process / Pneumatic Connection:
    1/2 NPT female process connectors
  • Wetted / Service Materials:
    S-code wetted assembly with Hastelloy C-276 diaphragm
  • Bolting / Mechanical Interface:
    B7 carbon steel bolts and nuts
  • Installation Arrangement:
    Horizontal piping with left-side high pressure
  • Housing:
    Cast aluminum amplifier housing
  • Electrical Connection:
    1/2 NPT female, two entries without blind plug
  • Local Indicator:
    Digital indicator
  • Mounting Hardware:
    304 SST flat 2-inch pipe bracket
  • Ordering Options:
    The /NF2 suffix specifies NEPSI Ex ia IIC T4 Ga intrinsic-safety approval for HART/BRAIN protocol types.
  • Degree of Protection:
    IP66/IP67, Type 4X
  • Ambient Conditions:
    -40 to 85°C (-40 to 185°F), or -30 to 80°C with LCD
  • Process / Service Temperature:
    -40 to 120°C (-40 to 248°F)
  • Communication Load / I/O:
    a total loop-load range of 0 to 1290 Ω, with 250 to 600 Ω required for digital communication
  • Stability / Control Performance:
    M/H/V stability ±0.1% of URL for 10 years; F ±0.2% per year
  • Manufacturer Reference:
    Yokogawa GS 01C31B01-01EN
  • Tariff Code:
    9026201090
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Operating Environment Safety Measurement Range

Features:

  • The NF2-approved low-span F-capsule configuration uses the 0.5 to 5 kPa (2 to 20 inH2O) capsule, horizontal piping with left-side high pressure and 1/2 NPT female, two entries without blind plug.
  • The NF2-approved low-span F-capsule configuration provides 4–20 mA DC with digital communication through HART 5/HART 7 protocol, with digital indicator.
  • The NF2-approved low-span F-capsule configuration combines 1/2 NPT female process connectors, S-code wetted assembly with Hastelloy C-276 diaphragm and 304 SST flat 2-inch pipe bracket.
The supplied EJA110E-JFS4J-912DB/NF2 variant is distinguished by F-capsule low-span configuration and open electrical entry arrangement.

It measures differential and static pressure for engineered flow, level, density or equipment-monitoring duties, with remote access through HART 5/HART 7 protocol.

Match F capsule, terminal-entry plug arrangement or NF2 approval to the existing assembly before wiring, pressurization or actuator movement.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Yokogawa EJA110E-JFS4J-912DB/NF2: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • The NF2-approved low-span F-capsule configuration measures differential pressure across a primary flow element, filter, heat exchanger or vessel connection.
  • The NF2-approved low-span F-capsule configuration supports inferred flow, level or density calculations when the impulse-piping and manifold design are validated.
  • The NF2-approved low-span F-capsule configuration provides differential and static-pressure information for process control, protection or condition monitoring.
  • For operating environment, the enclosure is intended for indoor or outdoor industrial use within -40 to 85°C (-40 to 185°F), or -30 to 80°C with LCD under pollution degree 2 conditions.
  • Process exposure must remain compatible with S-code wetted assembly with Hastelloy C-276 diaphragm and the selected fill-fluid requirements.
  • Vibration, impulse-line support and the horizontal piping with left-side high pressure position must remain within the official mounting guidance.
  • Isolation and depressurization are required before disturbing the 1/2 NPT female process connections.
  • Wetted-material compatibility must be confirmed for S-code wetted assembly with Hastelloy C-276 diaphragm to prevent leakage or diaphragm damage.
  • The /NF2 suffix specifies NEPSI Ex ia IIC T4 Ga intrinsic-safety approval for HART/BRAIN protocol types. It also governs the applicable entity parameters and temperature limits.
  • The selected capsule has a calibrated span of 0.5 to 5 kPa (2 to 20 inH2O) and an allowable configurable range of -5 to 5 kPa.
  • Zero may be elevated or suppressed only while both range endpoints remain inside the official capsule limits.
  • Range selection must consider expected pressure, overpressure, process temperature and the horizontal piping with left-side high pressure zero shift.
Description
EJA110E-JFS4J-912DB/NF2 is an order-code-specific EJA110E differential pressure transmitter. Its mechanical, electronic and option selections include F-capsule low-span configuration and open electrical entry arrangement.

It measures differential and static pressure for engineered flow, level, density or equipment-monitoring duties, with remote access through HART 5/HART 7 protocol. The configuration is intended for differential-pressure measurement across primary elements, filters, heat exchangers or vessels when the process and installation limits are satisfied.

Do not approve a substitute from appearance or family name alone. Check F capsule, terminal-entry plug arrangement or NF2 approval, the process connection and the installed loop documentation.
Alternative Names
EJA110E-JFS4J-912DB/NF2 Yokogawa EJA110E-JFS4J-912DB/NF2 EJA110E JFS4J 912DB NF2 EJA110E-JFS4J-912DB-NF2 EJA110EJFS4J912DBNF2 Yokogawa EJA110E Differential Pressure Transmitter Yokogawa EJA110E-JFS4J-912DB/NF2 Differential Pressure Transmitter Yokogawa DPharp EJA EJA110E-JFS4J-912DB/NF2
Technical notes
Seal both electrical entries with NF2-compatible hardware and prevent condensate or impulse-line head error from overwhelming the low-span F capsule.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which cover-flange bolting material is selected for EJA110E-JFS4J-912DB/NF2?
The order uses ASTM B7 carbon-steel bolting. Its suitability must be checked against ambient temperature, corrosion conditions and the site's material specification.
What enclosure-entry detail must the installer provide for EJA110E-JFS4J-912DB/NF2?
This configuration has two 1/2 NPT electrical entries without a blind plug. Approved glands and a suitable closure device must therefore be supplied for the actual wiring arrangement.
When is EJA110E-JFS4J-912DB/NF2 a suitable choice for low differential pressure?
It can serve low-head flow, level or pressure-drop duties when the 0.5 to 5 kPa span and process static pressure fall within the official limits.
What packaging protection should be requested when EJA110E-JFS4J-912DB/NF2 will be stored before installation?
Ask for sealed moisture-resistant packaging and protected open electrical entries, with the offered condition and storage duration stated in the quotation.
Which small configuration change can make a replacement unsuitable for EJA110E-JFS4J-912DB/NF2 service?
Changing the low-span capsule, bolting selection, left-high-pressure arrangement or /NF2 approval can invalidate the calibrated duty or installation compliance.
What should a technical inquiry for EJA110E-JFS4J-912DB/NF2 say about the open cable entries?
Identify the required gland thread, unused-entry closure, cable type and hazardous-area method, and request the EJA110E specification plus the applicable /NF2 installation documentation.