Features:
- The M-capsule configuration with local range setting uses the 1 to 100 kPa (4 to 400 inH2O) capsule, horizontal piping with left-side high pressure and 1/2 NPT female, two entries with blind plug.
- The M-capsule configuration with local range setting provides 4–20 mA DC with digital communication through HART 5/HART 7 protocol, with digital indicator with range-setting switch.
- The M-capsule configuration with local range setting combines 1/2 NPT female process connectors, S-code wetted assembly with Hastelloy C-276 diaphragm and 304 SST flat 2-inch pipe bracket.
The EJA110E-JMS4J-917EB suffix sequence selects range-setting indicator and B7 bolting on the M capsule within the EJA110E platform.
It measures differential and static pressure for engineered flow, level, density or equipment-monitoring duties, with remote access through HART 5/HART 7 protocol.
Confirm indicator type, bolting or high-pressure-side orientation before accepting the unit as a mechanical, electrical or functional replacement.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Yokogawa EJA110E-JMS4J-917EB:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- The M-capsule configuration with local range setting measures differential pressure across a primary flow element, filter, heat exchanger or vessel connection.
- The M-capsule configuration with local range setting supports inferred flow, level or density calculations when the impulse-piping and manifold design are validated.
- The M-capsule configuration with local range setting provides differential and static-pressure information for process control, protection or condition monitoring.
- For protection, the enclosure provides IP66/IP67, Type 4X protection only with all covers and cable-entry hardware fully secured.
- Pressure containment depends on the specified 1/2 NPT female process connectors and the chemical suitability of S-code wetted assembly with Hastelloy C-276 diaphragm.
- No additional option suffix is present, so approval-specific limits must be taken from the exact nameplate and base documentation.
- For efficiency, the two-wire 4–20 mA DC with digital communication loop combines power and measurement transmission while retaining HART 5/HART 7 protocol parameter access.
- When reviewing efficiency, remote setup and self-diagnostics reduce unnecessary enclosure opening during routine service activities.
- The selected digital indicator with range-setting switch supports local confirmation without adding a separate panel instrument where applicable.
- For compatibility, the receiving system must support HART 5/HART 7 protocol over the selected 4–20 mA DC with digital communication output and the applicable device revision.
- Mechanical replacement requires the same 1/2 NPT female process connectors, pressure capsule and high-pressure-side orientation.
- The digital indicator with range-setting switch and 304 SST flat 2-inch pipe bracket must fit the existing access, visibility and pipe-mounting plan.