Features:
- The B-capsule cover-flange gauge-pressure configuration uses the 0.14 to 16 MPa (20 to 2300 psi) capsule, horizontal piping with left-side high pressure and 1/2 NPT female, two entries with blind plug.
- The B-capsule cover-flange gauge-pressure configuration provides 4–20 mA DC with digital communication through HART 5/HART 7 protocol, with digital indicator.
- The B-capsule cover-flange gauge-pressure configuration combines 1/4 NPT female cover-flange pressure ports without separate process connectors, S-code wetted assembly with Hastelloy C-276 diaphragm and 304 SST flat 2-inch pipe bracket.
For EJA430E-JBS5J-917DB, the order code combines B capsule for the highest listed standard span as one matched configuration.
It converts gauge pressure into a control-system signal and supports configuration or diagnostic access through HART 5/HART 7 protocol.
Installation approval should include a documented check of B capsule pressure limit, port arrangement or flange bolting and the connected system.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Yokogawa EJA430E-JBS5J-917DB:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- The B-capsule cover-flange gauge-pressure configuration measures gauge pressure in process lines, vessels and utility systems handling compatible liquids, gases or steam.
- The B-capsule cover-flange gauge-pressure configuration supports pump discharge, header and equipment-pressure control where the selected pressure assembly is suitable.
- The B-capsule cover-flange gauge-pressure configuration supplies pressure feedback for control, monitoring or protective logic through an engineered instrument loop.
- When reviewing compliance, the transmitter family is designed to the applicable EN 61010 safety and EN 61326 EMC requirements listed by Yokogawa.
- In the documented compliance context, installed compliance depends on retaining the IP66/IP67, Type 4X enclosure, approved entries and specified process materials.
- For compliance acceptance, any hazardous-location claim must be supported by the exact option suffix and matching nameplate rather than the base family alone.
- For communication, the selected electronics carry HART 5/HART 7 protocol data on the documented 4–20 mA DC with digital communication measurement loop.
- When reviewing communication, digital communication is commissioned within a total loop-load range of 0 to 1290 Ω, with 250 to 600 Ω required for digital communication; verify the exact loop voltage at the transmitter terminals.
- Remote parameter access must use a host and device description that support the EJA430E DPharp EJA Series communication revision.
- When reviewing operating environment, the enclosure is intended for indoor or outdoor industrial use within -40 to 85°C (-40 to 185°F), or -30 to 80°C with LCD under pollution degree 2 conditions.
- When reviewing operating environment, process exposure must remain compatible with S-code wetted assembly with Hastelloy C-276 diaphragm and the selected fill-fluid requirements.
- In the documented operating environment context, vibration, impulse-line support and the horizontal piping with left-side high pressure position must remain within the official mounting guidance.