Features:
- The A-capsule connector configuration with local range setting uses the 0.03 to 3.5 MPa (4.3 to 500 psi) capsule, horizontal piping with left-side high pressure and 1/2 NPT female, two entries with blind plug.
- The A-capsule connector configuration with local range setting provides 4–20 mA DC with digital communication through HART 5/HART 7 protocol, with digital indicator with range-setting switch.
- The A-capsule connector configuration with local range setting combines 1/2 NPT female process connector, S-code wetted assembly with Hastelloy C-276 diaphragm and 304 SST flat 2-inch pipe bracket.
The EJA430E-JAS4J-917EB suffix sequence selects A capsule with range-setting indicator and 1/2 NPT connector within the EJA430E platform.
It converts gauge pressure into a control-system signal and supports configuration or diagnostic access through HART 5/HART 7 protocol.
Confirm local range switch, connector size or A capsule before accepting the unit as a mechanical, electrical or functional replacement.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Yokogawa EJA430E-JAS4J-917EB:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- The A-capsule connector configuration with local range setting measures gauge pressure in process lines, vessels and utility systems handling compatible liquids, gases or steam.
- The A-capsule connector configuration with local range setting supports pump discharge, header and equipment-pressure control where the selected pressure assembly is suitable.
- The A-capsule connector configuration with local range setting supplies pressure feedback for control, monitoring or protective logic through an engineered instrument loop.
- For safety, isolation and depressurization are required before disturbing the 1/2 NPT female process connection.
- When reviewing safety, wetted-material compatibility must be confirmed for S-code wetted assembly with Hastelloy C-276 diaphragm to prevent leakage or diaphragm damage.
- In the documented safety context, no approval-specific option suffix is included; use the exact nameplate and base documentation to determine the applicable limits.
- The selected capsule has a calibrated span of 0.03 to 3.5 MPa (4.3 to 500 psi) and an allowable configurable range of -0.1 to 3.5 MPa.
- When reviewing measurement range, zero may be elevated or suppressed only while both range endpoints remain inside the official capsule limits.
- In the documented measurement range context, range selection must consider expected pressure, overpressure, process temperature and the horizontal piping with left-side high pressure zero shift.
- For humidity range, the transmitter family is specified for 0 to 100% relative humidity when covers and cable entries are correctly sealed.
- When reviewing humidity range, condensation control depends on maintaining the IP66/IP67, Type 4X enclosure and using an approved conduit sealing method.
- In the documented humidity range context, the 1/2 NPT female, two entries with blind plug entry must prevent moisture migration into the terminal compartment during outdoor operation.