TC810

/ 4.9
1001 reviews | Need a Specific Revision?
TC810 is an Ethernet adapter for copper media with a built-in 2-port switch, two RJ45 ports, supporting single or redundant configurations for ABB Select I/O and 800xA systems.
Get a quick price for TC810
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for TC810

  • Manufacturer:
    ABB
  • Part Number:
    TC810
  • Product Family:
    ABB Advant OCS and Advant-800xA
  • Product Type:
    Ethernet Adapter
  • Description:
    Ethernet Adapter for copper media with built-in 2-port switch
  • Ports:
    2 x RJ45
  • Media Type:
    Copper (Ethernet)
  • Configuration:
    Single or redundant
  • RoHS Compliance:
    EU Directive 2011/65/EU
  • WEEE Category:
    5 (Small Equipment, ≤50 cm dimension)
  • Weight:
    0.12 kg
  • Estimated shipping dimensions:
    7.7x11x24.5cm
  • Tariff Code:
    8504401300
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Application Operating Environment Monitoring & Control

Features:

  • Integrates a two-port switch directly into the adapter, allowing daisy-chaining of devices without requiring an external network switch, reducing hardware and wiring costs.
  • Can be deployed as a single adapter for non-critical applications or in redundant pairs for high-availability systems requiring fault-tolerant communication.
  • Fully RoHS compliant, WEEE Category 5, battery-free, with SCIP registration for environmental compliance.
The TC810 eliminates the need for external network switches in small to medium I/O networks by integrating a 2-port switch directly into the adapter. This built-in switching capability allows field devices and controllers to be daisy-chained together using standard Ethernet cabling, significantly reducing both hardware costs and cabinet wiring complexity. The two RJ45 ports support copper media and provide seamless connectivity to ABB Select I/O systems and 800xA distributed control systems.

The TC810 offers deployment flexibility to match application availability requirements. For non-critical monitoring or control applications, a single TC810 provides cost-effective Ethernet connectivity. For mission-critical processes such as continuous manufacturing or power generation, two TC810 adapters can be configured redundantly alongside two CI845 modules and one TU860/TU865 termination unit.

The TC810 is engineered for space-efficient installation in modern control cabinets,it imposes minimal mechanical load on DIN rails. The adapter complies with EU RoHS Directive 2011/65/EU, restricting hazardous substances and ensuring environmental safety. It falls under WEEE Category 5 (Small Equipment) and contains no batteries, simplifying end-of-life disposal and reducing environmental impact.

The TC810 ABB Ethernet Adapter may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL)by the manufacturer (OEM).

ABB TC810 Ethernet Adapter Manuals, Datasheets,Drivers,Link Important Notice:Other accessories,manuals,cables,calibration data,software,etc.are not included with this equipment unless listed in the above stock item description.All prices are shown in USD.
ABB TC810 Ethernet Adapter Specs

General

  • Manufacturer ABB
  • Model TC810
  • Condition New Original ready stock
  • Product Family TC570 3BSE001458R1,TC562 3BSC630049R1
Important Notice:Other accessories,manuals,cables,calibration data,software,etc.are not included with this equipment unless listed in the above stock item description.All prices are shown in USD.
  • Process Industries: Heavily deployed in petrochemicals, oil refining, chemical processing, pharmaceuticals, and pulp & paper where continuous 24/7 operation is mandatory and unplanned shutdowns are cost-prohibitive.
  • Power & Energy Generation: Utilized in thermal, nuclear, and hydro power plants to handle high-speed data acquisition, turbine control, and safety interlock architectures.
  • Digital Marshalling & Distributed Control: Serves as the central Ethernet communication bridge between field-mounted Select I/O or S800 I/O clusters and the central AC 800M controller.
  • Extended Temperature Range: Supports operational temperatures from -40°C to +70°C , allowing direct installation in unheated or uncooled remote instrument enclosures (RIEs).
  • Marine & Offshore Capability: Carries major maritime approvals (such as DNV and ABS), certifying it for use on offshore drilling rigs, oil platforms, and marine vessels.
  • Altitude & Humidity: Operates reliably in 5% to 95% relative humidity (non-condensing) and at altitudes ranging from -1000m to 5000m.
  • Built-in 2-Port Switch: Equipped with 2 x RJ45 ports (100Base-TX Copper Media) that support Daisy Chain or Ring topologies (such as MRP) directly at the cabinet level, reducing external switch infrastructure.
  • Hardware Hot-Standby Redundancy: Supports dual-module redundancy when mounted on specialized Module Termination Units (MTUs) like the TU860 or TU865. If the primary adapter drops offline or encounters a fault, the backup unit takes over communications within milliseconds without interrupting process data.
  • Live Hot-Swapping: Modules can be removed or inserted under power (Hot Swap). The System 800xA engineer station automatically logs the event and alerts operators instantly without disturbing adjacent channels.
Description
The TC810 is designed as an Ethernet adapter for copper media, specifically for use with Ethernet Fieldbus Communication Interfaces (FCI). It features a built-in 2-port switch, eliminating the need for external network switches in small topologies. The TC810 hosts two standard RJ45 ports, allowing daisy-chaining or connection to redundant networks. 

For redundant setups, two TC810 adapters are used alongside two CI845 modules and one TU860 or TU865 termination unit. The TC810 is classified under HS Code 85176200 for electrical machinery and equipment. 

The TC810 complies with EU RoHS Directive 2011/65/EU and falls under WEEE Category 5 (Small Equipment with no external dimension exceeding 50 cm). This adapter contains no batteries, simplifying disposal and environmental compliance.

Typical applications for TC810 include connecting Select I/O systems to Ethernet networks in ABB 800xA distributed control systems. The TC810 supports both single (non-redundant) and redundant configurations, providing flexibility for different availability requirements. 
Alternative Names
TC8I0 TC81O TC520 3BSE001449R1 TC625 3BSE002224R1 TC 52P-N 4240 0410 80 TC530 3BUR000101R1 TC562 3BSC630049R1 TC570 3BSE001458R1
Technical notes
TC810 is a compact Ethernet adapter for copper media with integral 2-port switch. Supports single or redundant configurations. Two RJ45 ports enable daisy-chaining. RoHS compliant, WEEE Cat 5, no batteries.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is the primary purpose of TC810?
The TC810 is an Ethernet adapter for copper media that connects Select I/O systems to Ethernet networks. Its built-in 2-port switch allows daisy-chaining without external switches, reducing cabinet wiring complexity.
How do I configure TC810 for redundant operation?
For redundancy, use two TC810 adapters with two CI845 modules and one TU860 or TU865 termination unit. This provides fault-tolerant communication where one adapter takes over if the other fails.
What is the mounting requirements for TC810?
Its compact size allows DIN-rail mounting in standard control cabinets without requiring excessive space.
Is TC810 compliant with environmental and safety regulations?
Yes, TC810 complies with EU RoHS 2011/65/EU, is WEEE Category 5, contains no batteries.