Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotations, ABB records, R7 logistics planning, and high-current integration checks.

ACS580-01-206A-4

/ 4.9
1001 reviews | Need a Specific Revision?
ABB ACS580-01-206A-4 is a 110 kW, 206 A, 380-480 V IP21 ACS580-01 wall-mounted general purpose drive in frame R7.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for ACS580-01-206A-4
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ACS580-01-206A-4

  • Manufacturer:
    ABB
  • Part Number:
    ACS580-01-206A-4
  • Product Family:
    ABB Drives
  • Product Type:
    ACS580 General Purpose Wall-Mounted Drive
  • Stock:
    1
  • ABB Product ID:
    3AUA0000080506
  • Input Voltage:
    380 ... 480 V AC
  • Input Frequency:
    47.5 ... 63 Hz
  • Number of Phases:
    3-phase
  • Normal Output Current:
    206 A
  • Normal Output Power:
    110 kW
  • Light-duty Rating:
    196 A / 110 kW
  • Heavy-duty Rating:
    169 A / 90 kW
  • Maximum Output Current:
    287 A
  • Apparent Power Output:
    143 kV·A
  • Frame Size:
    R7
  • Degree of Protection:
    IP21
  • Mounting:
    Wall-mounted
  • Efficiency Level:
    IE2
  • Standby Loss:
    36 W
  • Temperature Rating:
    -15 to 40 °C
  • Standard Fieldbus:
    Modbus RTU
  • Weight:
    54 kg
  • Estimated shipping dimensions:
    28.4 x 88 x 37 cm
  • Tariff Code:
    85044087
  • Country of origin:
    Finland
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Duty Selection R7 Installation Fieldbus & Safety

Features:

  • 110 kW normal-use output rated 206 A at 400 V
  • R7 IP21 wall-mounted mechanical format
  • Standard Modbus RTU and Safe Torque Off resources
ACS580-01-206A-4 is the 206 A R7 configuration at the 110 kW point of the ACS580-01 400 V range.

The drive can integrate a high-power motor feeder with process references, plant I/O, serial communication, local operation, safety functions, and structured diagnostics.

Successful deployment depends on early agreement about transport and lifting, structural support, protection and conductors, heat removal, motor and braking duty, network ownership, safety testing, commissioning evidence, and service access.

Availability is subject to Apter Power's current inventory and sourcing confirmation.
ABB ACS580-01-206A-4 ACS580 General Purpose Wall-Mounted Drive Manuals, Datasheets, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ABB ACS580-01-206A-4 ACS580 General Purpose Wall-Mounted Drive Specs

General

  • ManufacturerABB
  • ModelACS580-01-206A-4
  • ConditionNew Original ready stock
  • Product FamilyABB ACS580-01 Drives
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

110 kW load verification

  • Normal use: Confirm the motor current and process load remain within the published 206 A point.
  • Light duty: Use the documented 196 A rating only with its specified overload cycle.
  • Heavy duty: Apply the 169 A / 90 kW point when the process requires the heavier overload profile.
  • Maximum current: Treat the 287 A value as the documented short-duration maximum, not a continuous rating.

High-power mechanical and electrical plan

  • Handling: Approve transport dimensions, route, lifting equipment, storage, and final orientation.
  • Power cables: Control lugs, conductor range, bend radius, support, torque, and phase spacing.
  • Cooling: Provide the documented airflow without obstruction or recirculation.
  • Access: Keep the panel, fans, terminals, communication, and safety circuits serviceable.

Control ownership and STO validation

  • Base protocol: Use Modbus RTU only after address, serial settings, mapping, and timeout are documented.
  • Other networks: Select an approved ABB adapter and verify firmware and engineering-tool support.
  • STO: Design and validate the Safe Torque Off circuit within the machine safety function.
  • Handover: Archive parameters, options, network data, safety tests, and rollback records.
Description
ACS580-01-206A-4 is the 110 kW, 206 A normal-use configuration in ABB's ACS580-01 wall-mounted range, built in frame R7 for 380-480 V three-phase systems.

ACS580-01-206A-4 provides process-oriented motor control with configurable I/O, standard Modbus RTU, local commissioning, and Safe Torque Off resources for high-power pumps, fans, conveyors, mixers, compressors, and similar engineered loads.

ACS580-01-206A-4 requires project-level coordination of transport and lifting, R7 support and airflow, 315 A fuse guidance, high-current cable and PE terminations, motor and braking duty, fieldbus ownership, safety validation, loaded commissioning, and maintenance access.
Alternative Names
ACS580 01 206A 4 ACS58001206A4 3AUA0000080506 ABB ACS580-01-206A-4 ABB 3AUA0000080506 ACS580-01 110 kW drive 206 A R7 wall-mounted drive ABB general purpose drive 110 kW
Technical notes
Before releasing ACS580-01-206A-4 for site installation, approve the R7 transport, lifting, mounting support, and 450 m³/h cooling-air path. The 110 kW, 206 A drive also requires the published 315 A IEC fuse basis, high-current conductor and PE design, motor-duty and braking calculations, Safe Torque Off wiring, fieldbus ownership, and controlled acceptance tests.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should ACS580-01-206A-4 be matched to a 110 kW motor?
Use the 206 A normal-duty point for the motor-current check, then compare the 196 A light-duty and 169 A heavy-duty ratings with the required overload cycle. This prevents a 110 kW nameplate value from being accepted without verifying the actual torque and overload profile.
What R7 installation work should be completed before ACS580-01-206A-4 arrives?
ACS580-01-206A-4 requires an approved handling route, lifting method, mounting support, cable-entry plan, service access, and a cooling path capable of the documented 450 m³/h airflow. Resolving these items before delivery avoids an inaccessible or thermally restricted R7 installation.
Why does ACS580-01-206A-4 require a dedicated feeder-coordination study?
The official IEC fuse basis is 315 A for this 206 A R7 rating. Use the site fault level, isolation device, conductor withstand, terminal limits, PE design, and selectivity study to prevent the high-power feeder from being copied from a lower-current drive design.
What braking review does ACS580-01-206A-4 require for its 287 A maximum-current capability?
For ACS580-01-206A-4, treat 287 A as a short-duration maximum rather than a continuous operating point. Calculate regenerative energy, peak power, stopping time, repetition, motor duty, DC-bus limits, and the approved braking arrangement before accepting a rapid-stop or overhauling-load application.
How should Modbus RTU and Safe Torque Off be commissioned on ACS580-01-206A-4?
ACS580-01-206A-4 needs separate evidence for Modbus addressing, mapping, timeout response, and control ownership, plus validation of the Safe Torque Off circuit within the machine safety function. A successful network test does not prove that the STO wiring or safety response is correct.
Which loaded-test records are essential for ACS580-01-206A-4 site acceptance?
Retain the 206 A duty basis, motor data, protection settings, conductor and torque records, cooling observations, accepted parameters, Modbus tests, STO validation, loaded current and speed readings, fault history, and backups. These records establish the approved R7 configuration for maintenance and recovery.