Technical specifications for 07 KT 97

  • Manufacturer:
    ABB
  • Part Number:
    07 KT 97
  • Product Family:
    ABB Procontic
  • Product Type:
    Advant Controller 31 AC31 Basic Unit
  • Stock:
    1
  • Supply:
    24 V DC basic unit
  • Digital I/O:
    24 digital inputs and 16 transistor outputs
  • Configurable I/O:
    Eight configurable digital I/O
  • Analog inputs:
    Eight inputs configurable for signal or Pt100 use
  • Analog outputs:
    Four analog outputs
  • Serial interfaces:
    Two interfaces for Modbus or programming
  • Fieldbus:
    CS31 system bus
  • Memory:
    480 kB program memory and 256 kB user-data Flash
  • Accessories documented:
    07 LE 90 external battery and SmartMedia memory card
  • Tariff Code:
    8538900000
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals I/O and Signal Setup Memory and Communication Commissioning Checks Application
  • 24 V DC Advant Controller 31 basic unit
  • Mixed digital and configurable analog I/O
  • CS31 bus, serial interfaces, and Flash memory

07 KT 97 is an ABB Advant Controller 31 basic unit supplied from a 24 V DC source.

The unit combines digital inputs and transistor outputs with configurable analog or Pt100 inputs, analog outputs, serial interfaces, a CS31 system bus, and internal Flash memory.

Match the saved application, I/O configuration, communication settings, memory media, and field wiring before replacement or commissioning.

Availability, condition, price, and shipping time for 07 KT 97 are confirmed during quotation.

ABB 07 KT 97 Advant Controller 31 Manuals, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, and memory media are not included unless listed in the stock item description. All prices are shown in USD.

  • 24 digital inputs and 16 transistor outputs
  • Eight configurable inputs for standard signals or Pt100 sensors
  • Four analog outputs for process control
  • Two serial interfaces for programming or Modbus communication
  • CS31 system bus for distributed controller communication
  • 480 kB program memory and 256 kB user data Flash
  • Confirm 24 V DC polarity, protection, and supply stability
  • Restore the saved I/O, serial, and CS31 configuration
  • Check the SmartMedia card and 07 LE 90 battery arrangement
  • Advant Controller 31 machine control with mixed digital and analog signals
  • Pt100 temperature acquisition through configurable analog inputs
  • CS31 distributed I/O and Modbus connected automation stations
Description
07 KT 97 is an Advant Controller 31 basic unit combining central control, digital and analog I/O, serial interfaces, and CS31 fieldbus connectivity.

The reviewed ABB manual documents a 24 V DC basic unit with 24 digital inputs, 16 transistor outputs, configurable analog channels, Modbus/programming serial interfaces, CS31 bus communication, Flash memory, and SmartMedia support.

Before installation or replacement, confirm the 24 V DC supply, I/O wiring, analog signal configuration, serial protocol settings, battery/memory accessories, and saved application.
Alternative Names
07KT97 07 KT97 07KT 97 ABB 07 KT 97 Advant Controller 31 07 KT 97 AC31 07 KT 97
Technical notes
07 KT 97: confirm the 24 V DC supply, required analog signal and Pt100 configuration, CS31 bus wiring, serial protocol settings, memory card, battery status, and saved application; mismatched I/O or configuration can change process behavior.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What should be verified before ordering ABB 07 KT 97?
Match the complete ABB 07 KT 97 identity, 24 V DC supply, installed I/O arrangement, host project, and required communication interfaces before ordering.
How should the existing analog configuration be preserved when replacing ABB 07 KT 97?
Record every analog channel as a standard signal or Pt100 measurement, including scaling and wiring, then restore the same configuration for ABB 07 KT 97.
What must be backed up before removing ABB 07 KT 97?
Back up the application, I/O map, CS31 station data, serial settings, memory-card contents, and battery or clock information before removing ABB 07 KT 97.
Can ABB 07 KT 97 be used in a standalone or CS31 installation?
Yes. ABB documents 07 KT 97 for standalone use and CS31 master or slave operation; select the mode that matches the saved control-system project.
What should be checked if ABB 07 KT 97 powers up but the process outputs change?
Check the restored program, I/O mapping, analog scaling, relay wiring, and CS31 data, then test outputs in a controlled sequence before returning ABB 07 KT 97 to service.
Which serial settings must be recorded for ABB 07 KT 97?
Record the programming or Modbus role, protocol settings, addressing, and connected-device parameters so the serial interfaces on ABB 07 KT 97 match the existing installation.
How should ABB 07 KT 97 be commissioned after replacement?
Restore the verified application for ABB 07 KT 97, test digital and analog points including Pt100 channels, check serial links and CS31 diagnostics, and complete the approved machine sequence before normal operation.