Technical specifications for 1336-QOUT-SP13A

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    1336-QOUT-SP13A
  • Product Family:
    1336 Drives
  • Product Type:
    Output Transistor Assembly
  • Stock:
    1
  • Drive Family:
    1336 PLUS / 1336 FORCE / 1336 IMPACT / 1336 PLUS II
  • Voltage Application:
    230 V / 460 V
  • Drive Rating:
    50 HP at 230 V; 100 HP at 460 V
  • Drive Frame:
    Frame D
  • Drive Configuration:
    Stand-alone or common-bus
  • Spare-Part Level:
    Level 2
  • Troubleshooting Guide Symbol:
    Q1–Q3 or Q1–Q6
  • Official Kits Required per Drive:
    3
  • Tariff Code:
    8504909000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Drive Matching Power Stage Service Checks Application
  • Output-transistor assembly for selected Bulletin 1336 drive power stages
  • Documented for 460 V, 100 HP 1336S/T/E/F drives
  • Official spare-parts table lists three assemblies per compatible drive

1336-QOUT-SP13A is an output-transistor assembly used in selected Allen-Bradley Bulletin 1336 adjustable-frequency drive power stages.

Rockwell Automation lists it for 460 V, 100 HP 1336S, 1336T, 1336E, and 1336F drives, with three assemblies per drive.

Before replacement, isolate and discharge the drive, test every phase and related gate-driver path, and confirm the full host-drive catalog and service scope.

Availability, condition, price, and shipping time for 1336-QOUT-SP13A are confirmed during quotation.

Allen-Bradley 1336-QOUT-SP13A Output Transistor Assembly Manuals, Product Family, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Match the assembly to a 460 V, 100 HP host drive
  • Verify the complete 1336S/T/E/F catalog and series
  • Do not substitute another QOUT assembly by appearance
  • The official table lists three output assemblies per drive
  • Test every phase and the associated gate-driver paths
  • Inspect bus, snubber, current-feedback, motor, and cable circuits
  • Discharge the DC bus and follow lockout procedures
  • Confirm insulation, thermal interface, fasteners, and gate leads
  • Commission under controlled conditions after repair
  • Adjustable-frequency induction-motor speed control in compatible 1336 PLUS and 1336 PLUS II drive systems
  • High-performance speed, torque, and tension control in compatible 1336 FORCE drive applications
  • Zero-speed torque control for demanding machinery using compatible 1336 IMPACT drives
Description
1336-QOUT-SP13A is an output-transistor assembly for selected Allen-Bradley Bulletin 1336 adjustable-frequency drives.

Official spare-parts documentation identifies it for 460 V, 100 HP 1336S, 1336T, 1336E, and 1336F drives and lists three assemblies per drive.

Service requires complete phase, gate-driver, DC-bus, motor, and cable testing, plus verification of all installation hardware and the exact host-drive catalog.
Alternative Names
1336-QOUT-SP13A 1336 QOUT SP13A 1336QOUTSP13A Allen-Bradley 1336-QOUT-SP13A Allen Bradley 1336-QOUT-SP13A AB 1336-QOUT-SP13A Rockwell Automation 1336-QOUT-SP13A
Technical notes
Allen-Bradley 1336-QOUT-SP13A matches 460 V, 100 HP 1336S/T/E/F drives; test all phases, gate drivers, bus components, motor, and cabling before replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How can technicians distinguish an Allen-Bradley 1336-QOUT-SP13A fault from a motor or cable fault?
Isolate the motor circuit and follow the official service tests for each output phase, gate path, DC bus, motor cable, and motor insulation. Fault codes alone do not identify the failed component.
Does replacing Allen-Bradley 1336-QOUT-SP13A require the drive parameters to be reconfigured?
The output assembly is not normally the parameter-storage device, but the complete parameter set and fault history should still be backed up. Verify motor data and protective settings before operation.
Can a drive be returned directly to full load after installing Allen-Bradley 1336-QOUT-SP13A?
A staged restart is safer. Confirm insulation, phase balance, gate operation, current feedback, motor rotation, unloaded current, acceleration, and fault-free operation before restoring the normal production load.
Does Allen-Bradley 1336-QOUT-SP13A include every item needed for installation?
Do not assume so. Verify whether gate leads, fasteners, insulating pads, thermal compound, bus hardware, current sensors, or associated driver components are separately required.
Can only one Allen-Bradley 1336-QOUT-SP13A be replaced after an output fault?
Only after testing all phases and following the drive service procedure. A failed assembly may be accompanied by gate-driver, bus, motor-cable, grounding, or load faults.
What electrical checks should precede installation of Allen-Bradley 1336-QOUT-SP13A?
Safely discharge the DC bus, test each power device and phase, inspect gate leads and snubbers, check the motor and cable, and verify no short remains.
How should the thermal interface be handled when fitting Allen-Bradley 1336-QOUT-SP13A?
Use the drive’s service procedure for approved insulating pads or compound, surface cleaning, fastener sequence, and torque. An incorrect thermal or insulating interface can cause rapid failure.