Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued
    Discontinued date: 2025-08-04

2094-BC04-M03-M

/ 4.9
1001 reviews | Need a Specific Revision?
Allen-Bradley 2094-BC04-M03-M is a 27.6 kW two-slot Kinetix 6200/6500 Integrated Axis Module for 400/460 V-class systems.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for 2094-BC04-M03-M
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2094-BC04-M03-M

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2094-BC04-M03-M
  • Product Family:
    Kinetix Servo Drive
  • Product Type:
    Integrated Axis Module
  • Stock:
    1
  • Voltage Class:
    400/460 V-class
  • AC Input:
    324...528 V rms three-phase
  • Input Frequency:
    47...63 Hz
  • Common-bus DC Input:
    458...747 V DC
  • Continuous Bus Current:
    41.5 A DC
  • Converter Output:
    27.6 kW continuous
  • Inverter Current:
    21.2 A rms continuous; 30.0 A 0-pk continuous
  • Inverter Output:
    13.5 kW continuous
  • Module Configuration:
    Integrated converter plus two inverter slots
  • Weight:
    9.6 kg
  • Estimated shipping dimensions:
    19.6 × 27.2 × 25.6 cm
  • Tariff Code:
    8503009090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Rail Thermal Feedback Application
  • Wider modular IAM power section combines a line-side converter with two inverter rail positions
  • Compatible Kinetix 6200 or Kinetix 6500 control hardware is selected separately
  • The IAM supplies a shared Bulletin 2094 DC rail for the engineered multi-axis configuration
2094-BC04-M03-M serves as the integrated power entry and first higher-current servo axis in a modular Bulletin 2094 assembly.

The separately installed control module establishes the motion network and feedback behavior, while the wider power section occupies the converter position and two inverter slots.

Plan the rail layout, safe handling, total DC demand, shunt duty, motor and feedback pairing, cable access, protective devices, grounding, firmware, and enclosure airflow before installation.

Availability, condition, price, and shipping time for 2094-BC04-M03-M are confirmed during quotation.

Allen-Bradley 2094-BC04-M03-M Kinetix 6200/6500 Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • The IAM combines the converter position with two inverter slots on a supported Bulletin 2094 power rail
  • Compatible additional axis modules are installed to the right within the converter and rail limits
  • The complete rail catalog number and slot arrangement must be verified before moving existing modules
  • The open-type module must be installed in a suitable enclosure with the documented ambient limits
  • Vertical orientation and specified top and bottom clearances are required for cooling airflow
  • Total enclosure heat dissipation must include the IAM, control module, rail axes, shunt hardware, and adjacent equipment
  • Feedback support is determined by the Kinetix 6200 or Kinetix 6500 control module fitted to the power section
  • Motor and feedback pairings must follow the Rockwell Automation compatibility and sizing tables
  • Connector kits, cable catalog numbers, shielding, and feedback power requirements must match the selected device
  • Higher-capacity Bulletin 2094 multi-axis systems that need an integrated converter and one modular servo axis
  • SERCOS motion systems assembled with a compatible Kinetix 6200 control module
  • Integrated Motion over EtherNet/IP systems assembled with a compatible Kinetix 6500 control module
Description
2094-BC04-M03-M is an Allen-Bradley Kinetix 6200/6500 Integrated Axis Module with an integrated 400/460 V-class converter and a two-slot modular inverter section for a Bulletin 2094 power rail.

It accepts 324...528 V rms three-phase input at 47...63 Hz, provides 27.6 kW continuous converter output, and supplies 21.2 A rms continuous or 30.0 A 0-pk continuous inverter current with 13.5 kW continuous inverter output.

Confirm the required rail width, lifting and mounting plan, selected control module, total connected load, regenerative duty, shunt capacity, motor-feedback interface, branch protection, cabling, grounding, firmware, and enclosure thermal design.
Revisions

Revision Part #

Also known as

2094-BC04-M03-M Series B
2094-BC04-M03-M/B, Series B
Alternative Names
2094-BC04-M03-M 2094BC04-M03-M 2094 BC04 M03 M 2094BC04M03M Allen-Bradley 2094-BC04-M03-M Allen Bradley 2094-BC04-M03-M AB 2094-BC04-M03-M Rockwell Automation 2094-BC04-M03-M
Technical notes
2094-BC04-M03-M uses a wider two-slot inverter section on a modular Bulletin 2094 rail. Verify rail space, lifting and cooling provisions, control hardware, total load, regeneration, and cable clearances.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How much Bulletin 2094 rail space must be planned for Allen-Bradley 2094-BC04-M03-M?
Allen-Bradley 2094-BC04-M03-M combines the converter with a two-inverter-slot power section. Confirm the exact power-rail catalog number, adjacent clearances, connector access, and complete module arrangement before installation.
What lifting and handling checks apply to Allen-Bradley 2094-BC04-M03-M?
Use the handling and mounting procedure in the Bulletin 2094 installation instructions, support the module during placement, and verify rail engagement and fasteners before connecting line, bus, motor, or feedback wiring.
Which control module is required for Allen-Bradley 2094-BC04-M03-M?
Select the compatible Kinetix 6200 control module for SERCOS systems or Kinetix 6500 control module for Integrated Motion over EtherNet/IP systems, then match controller and firmware revisions.
How should regenerative loading be checked for Allen-Bradley 2094-BC04-M03-M?
Calculate regeneration from every connected motor, load inertia, speed profile, deceleration, vertical load, and duty cycle; then verify the IAM, shared DC rail, and shunt capacity with official sizing resources.
What must be compared before replacing Allen-Bradley 2094-BC04-M03-M with a newer architecture?
Compare input supply, converter and axis loading, motor and feedback support, rail and enclosure mechanics, cable interfaces, shunt arrangement, network, firmware, and machine-safety requirements.
Where are wiring and clearance requirements for Allen-Bradley 2094-BC04-M03-M documented?
Use the Bulletin 2094 installation instructions for mounting, conductors, connectors, shield terminations, grounding, and clearances, and the Kinetix 6200/6500 user manual for system integration.
Which nameplate details should be photographed when sourcing Allen-Bradley 2094-BC04-M03-M?
Photograph the full catalog number, Series 1 marking, ratings, serial information, and fitted control module; also provide quantity, required condition, motor/feedback combination, and any cable or connector needs.