2198-E1020-ERS

/ 4.9
1001 reviews | Need a Specific Revision?
Allen-Bradley 2198-E1020-ERS Kinetix 5100 Servo Drive: 1.0 kW at 120 V single-phase or 2.0 kW at 230 V single-phase or three-phase.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 2198-E1020-ERS
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2198-E1020-ERS

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2198-E1020-ERS
  • Product Family:
    Kinetix Servo Drive
  • Product Type:
    Servo Drive
  • Stock:
    1
  • 120 V AC Input:
    95...132 V rms single-phase
  • 230 V AC Single-Phase Input:
    170...253 V rms single-phase
  • 230 V AC Three-Phase Input:
    170...253 V rms three-phase
  • Continuous Output Power:
    1.0 kW at 120 V single-phase; 2.0 kW at 230 V single-phase or three-phase
  • Continuous Output Current:
    13.4 A rms
  • Peak Output Current:
    40.58 A rms for up to 1.8 seconds
  • Network:
    Dual-port EtherNet/IP
  • Safety Option:
    Safe Torque Off
  • Weight:
    2.7 kg
  • Estimated shipping dimensions:
    9.5 × 18.0 × 20.8 cm
  • Tariff Code:
    8503009090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Diagnostics & Protection Performance & Efficiency Firmware & Updates Application

Features:

  • Kinetix 5100 200 V-class configuration for the 2198-E1020-ERS catalog number
  • Standard I/O and auxiliary feedback connections for documented system integration
  • Two RJ45 EtherNet/IP ports and a dedicated Safe Torque Off connection
Allen-Bradley 2198-E1020-ERS accepts 95...132 V rms single-phase input for 1.0 kW output, or 170...253 V rms single-phase or three-phase input for 2.0 kW output.

Its 13.4 A rms continuous output and 40.58 A rms peak output for up to 1.8 seconds identify this catalog configuration. Actual axis performance depends on the selected motor, feedback hardware, load inertia, duty cycle, and regeneration.

Confirm controller mode, motor/feedback compatibility, branch protection, wiring, cooling, grounding, cable clearance, axis duty, and Safe Torque Off requirements before selection.

Availability, condition, price, and shipping time for 2198-E1020-ERS are confirmed during quotation.
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • The drive display presents status information and fault codes for local review
  • For 120/230 V single-phase input, Rockwell Automation lists the LPJ-40SP fuse and 1489-M2D400 circuit breaker
  • For 230 V three-phase input, Rockwell Automation lists the LPJ-35SP fuse and 1489-M3D300 circuit breaker
  • Maximum published power loss is 139.83 W at the documented test condition
  • Published line-loss ride-through is 20 ms
  • The internal shunt is rated 20 ohms with 20 W continuous shunt power
  • ControlFLASH Plus software is supported for upgrading Kinetix 5100 drive firmware
  • ControlFLASH software is also documented as a firmware-upgrade method
  • Inhibit the module before the upgrade and verify the installed firmware after the procedure
  • Single-axis indexing applications sized for the documented 1.0 kW rating at 120 V single-phase
  • Single-axis indexing applications sized for the documented 2.0 kW rating at 230 V single-phase or three-phase
  • Standalone or controller-based Kinetix 5100 motion systems using supported control modes and matched motor/feedback hardware

Use current Rockwell Automation sizing and design resources to validate the actual torque-speed profile, duty cycle, regeneration, motor and feedback interfaces, controller, protection, cabling, enclosure cooling, grounding, and Safe Torque Off requirements.

Description
2198-E1020-ERS is an Allen-Bradley Kinetix 5100 200 V-class Servo Drive. Its documented output ratings are 1.0 kW at 120 V single-phase and 2.0 kW at 230 V single-phase or three-phase, with 13.4 A rms continuous output and 40.58 A rms peak output for up to 1.8 seconds.

The drive provides dual-port EtherNet/IP, standard I/O, auxiliary feedback connectivity, and Safe Torque Off. Separate mains and control-power connections support integration into a documented Kinetix 5100 motion system.

Confirm the complete catalog number, actual supply voltage and phase, motor and feedback combination, controller configuration, branch protection, cable set, grounding, enclosure cooling, axis duty, and STO circuit before installation or replacement.
Alternative Names
2198-E1020-ERS 2198-E1020ERS 2198 E1020 ERS 2198E1020ERS Allen-Bradley 2198-E1020-ERS Allen Bradley 2198-E1020-ERS AB 2198-E1020-ERS Rockwell Automation 2198-E1020-ERS Kinetix 5100 2198-E1020-ERS
Technical notes
Allen-Bradley 2198-E1020-ERS is the 13.4 A rms continuous Kinetix 5100 configuration rated 1.0 kW at 120 V single-phase or 2.0 kW at 230 V single-phase or three-phase, with 40.58 A rms peak output for up to 1.8 seconds. Verify supply phase, motor/feedback hardware, protection, cooling, cabling, and Safe Torque Off wiring for the installed system.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which input supplies and output ratings are documented for Allen-Bradley 2198-E1020-ERS?
Rockwell Automation documents 95...132 V rms single-phase input for the 1.0 kW at 120 V rating, plus 170...253 V rms single-phase or three-phase input for the 2.0 kW at 230 V rating. The continuous output current is 13.4 A rms.
Which controller and network details should be checked for Allen-Bradley 2198-E1020-ERS compatibility?
Allen-Bradley 2198-E1020-ERS provides two standard RJ45 EtherNet/IP ports. Confirm the controller type, supported Kinetix 5100 control mode, network topology, firmware requirements, motor/feedback interfaces, and STO wiring in the current Rockwell Automation documentation before selection.
Is the 40.58 A rms rating of Allen-Bradley 2198-E1020-ERS intended for continuous application duty?
No. Rockwell Automation specifies 40.58 A rms as the peak output current for up to 1.8 seconds; the continuous output rating is 13.4 A rms. Check the actual acceleration, deceleration, load inertia, cycle repetition, regeneration, and enclosure thermal conditions when sizing the axis.
What control-power requirement should be checked for Allen-Bradley 2198-E1020-ERS?
Rockwell Automation lists separate 120/230 V control-power input. For Allen-Bradley 2198-E1020-ERS, control-power current is 0.63 A rms at 120 V or 0.35 A rms at 230 V. Confirm the selected protection, wiring, grounding, and power-up sequence against the current user manual.
What installation differences matter when Allen-Bradley 2198-E1020-ERS replaces another servo drive?
Verify the exact catalog number, 9.5 × 18.0 × 20.8 cm enclosure, 2.70 kg weight, supply voltage and phase, control power, motor and auxiliary feedback connectors, dual-port EtherNet/IP layout, branch protection, cable bend clearance, cooling, grounding, and Safe Torque Off circuit. Do not treat matching power alone as proof of interchangeability.
Which official manuals should be consulted for Allen-Bradley 2198-E1020-ERS?
Use the current Kinetix Servo Drives Specifications publication KNX-TD003, the Kinetix 5100 EtherNet/IP Indexing Servo Drives User Manual 2198-UM004, and the Kinetix 5100 Drive Systems Design Guide 2198-PC003. Confirm the revision shown on Rockwell Automation Literature Library before design or service work.
What information helps Apter quote Allen-Bradley 2198-E1020-ERS accurately?
Provide the complete model 2198-E1020-ERS, quantity, delivery destination, required condition, target date, actual 120 V or 230 V supply and phase, controller, motor and feedback hardware, application duty, and any documentation requirements. Apter can then check availability and configuration details for the quotation.