Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Supply Note: Apter Power provides quotation, sourcing, technical-document, and application-matching support for 2198-E4075-ERS.

2198-E4075-ERS

/ 4.9
1001 reviews | Need a Specific Revision?
Allen-Bradley 2198-E4075-ERS is a Frame F Kinetix 5100 400 V-class Servo Drive rated 7.50 kW with 31.0 A rms continuous output.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 2198-E4075-ERS
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2198-E4075-ERS

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2198-E4075-ERS
  • Product Family:
    Kinetix Servo Drive
  • Product Type:
    Servo Drive
  • Stock:
    1
  • Voltage Class:
    400 V Class
  • Frame:
    Frame F
  • Input Voltage:
    342...528 V rms three-phase
  • Nominal Input:
    380/480 V three-phase
  • Input Frequency:
    47...63 Hz
  • Continuous Output Power:
    7.50 kW at 480 V three-phase
  • Continuous Output Current:
    31.0 A rms
  • Peak Output Current:
    53.32 A rms for up to 1.8 seconds
  • Control Power:
    24 V DC nominal
  • Network:
    Dual-port EtherNet/IP
  • Safety:
    Safe Torque Off (STO)
  • Lifecycle Status:
    Active
  • Weight:
    10 kg
  • Estimated shipping dimensions:
    14.1 × 31.2 × 22.5 cm
  • Tariff Code:
    8503009090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Cooling Regeneration Installation Application

Features:

  • Frame F Kinetix 5100 400 V-class catalog configuration
  • Dedicated motor and auxiliary feedback connections
  • Separate 24 V DC control-power input

2198-E4075-ERS is the 7.50 kW catalog configuration for 342...528 V rms three-phase input.

The drive supports standalone pulse, analog, and indexed position commands together with EtherNet/IP device communication.

Verify the controller, motor and feedback, command signals, connector kits, protection, cable set, grounding, enclosure conditions, regeneration, and safety circuit before installation.
Current availability, condition, price, and shipping time for 2198-E4075-ERS are checked during quotation.

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Maximum published power loss is 467 W at 380 V input
  • Maximum published power loss is 494 W at 480 V input
  • Power-loss data is used to size enclosure ventilation
  • Internal shunt capability is evaluated from the actual regenerative duty
  • Bulletin 2198 external shunt modules are listed for supported configurations
  • Vertical loads and rapid deceleration require regeneration review
  • A separate motor-brake cable is required for drives rated 5.5 kW and above
  • Protective-earth grounding and shield bonding follow publication 2198-UM004
  • AC line filters are applied where specified for the required compliance condition
  • Higher-current digital-I/O indexed motion sequences
  • Pulse-command single-axis position control
  • Analog-command speed or torque control
Description
2198-E4075-ERS is an Allen-Bradley Kinetix 5100 400 V-class Servo Drive for higher-current standalone indexing and single-axis motion applications.

The Frame F drive accepts 342...528 V rms three-phase input at 47...63 Hz. Its official output ratings are 7.50 kW at 480 V three-phase, 31.0 A rms continuous, and 53.32 A rms peak for up to 1.8 seconds.

Dual-port EtherNet/IP, standard command I/O, feedback interfaces, and Safe Torque Off support system integration. Confirm motor current, feedback, motor-brake cabling, protection, ventilation, regenerative energy, external shunt needs, and STO wiring.
Revisions

Revision Part #

Also known as

2198-E4075-ERS Series 1
2198-E4075-ERS/1, Series 1
Alternative Names
2198-E4075-ERS 2198-E4075ERS 2198 E4075 ERS 2198E4075ERS Allen-Bradley 2198-E4075-ERS AB 2198-E4075-ERS Allen Bradley 2198-E4075-ERS Rockwell Automation 2198-E4075-ERS Kinetix 5100 2198-E4075-ERS
Technical notes
2198-E4075-ERS is a Frame F 7.50 kW drive; verify motor current, separate brake cabling, enclosure ventilation, regeneration, external shunt selection, and STO wiring.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What axis-duty checks are important for Allen-Bradley 2198-E4075-ERS at 31.0 A rms continuous output?
Use Rockwell Automation sizing tools and motor/drive selection data to verify the motor torque-speed curve, load inertia, motion profile, acceleration and deceleration time, duty cycle, and regenerative requirement. Treat 31.0 A rms continuous and 53.32 A rms peak for up to 1.8 seconds as drive limits; final sizing must satisfy the selected motor, mechanical load, and installation constraints.
Does Allen-Bradley 2198-E4075-ERS require a separate motor-brake cable?
Rockwell Automation documents a separate motor-brake cable for Kinetix 5100 drives rated 5.5 kW and above. Verify the supported motor, brake voltage, brake cable, power cable, feedback cable, connector hardware, and installation routing.
What enclosure information should be checked when applying Allen-Bradley 2198-E4075-ERS?
Use the published power-loss data to size enclosure ventilation, maintain required clearances, and evaluate ambient temperature and airflow. Also check branch protection, line-filter requirements, grounding, shield bonding, and heat from adjacent equipment.
Can Apter quote Allen-Bradley 2198-E4075-ERS in a requested item condition?
Yes, subject to current availability. Rockwell Automation lists the catalog number as Active, while Apter verifies the requested condition, quantity, inspection requirement, price, lead time, and shipment schedule for each inquiry.
Which regenerative conditions must be reviewed before substituting Allen-Bradley 2198-E4075-ERS?
Check motor and load inertia, maximum speed, deceleration time, vertical-load behavior, repeated duty, internal shunt capability, external shunt requirements, bus voltage, enclosure cooling, and the complete motor/feedback and safety interfaces.
Which official documents help compare current and thermal data for Allen-Bradley 2198-E4075-ERS?
KNX-TD003 provides model-specific power, current, power-loss, protection, weight, and environmental data. Publication 2198-UM004 provides installation, wiring, configuration, commissioning, and troubleshooting requirements.
What should a sourcing request for Allen-Bradley 2198-E4075-ERS include?
Include quantity, destination, condition, three-phase supply, motor/feedback numbers, controller command method, axis duty, regenerative profile, enclosure limits, shunt, safety, connector, cable, and delivery requirements so Apter can review the complete configuration.