- Line-side DC-bus supply for a correctly sized Kinetix 5700 shared-bus system
- 55 mm format interfaces with the documented common-bus connector hardware
- Separate control-power and mains connections support coordinated system operation
Allen-Bradley 2198-P070 establishes the common DC bus for connected Kinetix 5700 inverter modules.
Filter, reactor, contactor, protective devices, and bus connectors must be selected for the complete mains and drive configuration.
Confirm hardware Series, firmware, connected inverter load, total bus capacitance, regeneration, conductor routing, grounding, and enclosure cooling before commissioning.
Availability, condition, price, and shipping time for 2198-P070 are confirmed during quotation.
Allen-Bradley 2198-P070 Kinetix 5700 DC Bus Supply Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- DBR40-F and DB42-F are documented line-filter choices for the supply arrangement
- The selected filter affects the permitted combined motor-cable design
- Filter placement and conductor routing must follow the installation instructions
- 2198-BARCON-55DCAC100 supports the applicable 55 mm bus connection
- The supply contributes 780 µF to the connected DC-bus capacitance
- Total bus capacitance must include every connected Kinetix 5700 inverter
- LPJ-40SP is listed for the documented branch-circuit arrangement
- 100-C37EJ10 is the documented contactor selection
- 1321-3R35-B is the documented line-reactor selection
- Multi-axis Kinetix 5700 systems operating from a shared DC bus
- 240 V systems whose connected load fits the documented supply limits
- 480 V systems whose connected load and regeneration are verified by sizing tools