Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active

2198-H015-ERS

/ 4.9
1001 reviews | Need a Specific Revision?
Allen-Bradley 2198-H015-ERS is a Frame 2 Kinetix 5500 Servo Drive with 5.0 A rms continuous output and hardwired Safe Torque Off.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 2198-H015-ERS
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2198-H015-ERS

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2198-H015-ERS
  • Product Family:
    Kinetix Servo Drive
  • Product Type:
    Kinetix 5500 Servo Drive
  • Stock:
    1
  • Frame:
    Frame 2
  • Input Supply:
    195...264 V rms single-phase; 195...264 V rms three-phase; 324...528 V rms three-phase
  • Output Power:
    1.0 kW at 230 V single-phase; 1.5 kW at 230 V three-phase; 3.2 kW at 480 V three-phase
  • Continuous Output Current:
    5.0 A rms; 7.1 A 0-pk
  • Peak Output Current:
    12.5 A rms; 17.7 A 0-pk
  • Network:
    Integrated Motion over EtherNet/IP
  • Safety:
    Hardwired Safe Torque Off
  • Dimensions:
    5.5 × 22.5 × 26.5 cm
  • Weight:
    2.3 kg
  • Tariff Code:
    8503009090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Protection Cabling Firmware Applications
  • Frame 2 Kinetix 5500 platform for one independently sized servo axis
  • Integrated Motion over EtherNet/IP links the axis with a supported Logix controller
  • Hardwired Safe Torque Off provides the documented drive safety interface

Allen-Bradley 2198-H015-ERS is integrated with a supported controller, motor, DSL feedback device, brake option, and approved 2090 cable.

Selection must distinguish its 230 V single-phase, 230 V three-phase, and 480 V three-phase operating points before motor or protective-device sizing.

Verify the load profile, controller and drive firmware, feedback and brake interfaces, branch protection, regeneration, grounding, enclosure cooling, and safety validation before commissioning.

Availability, condition, price, and shipping time for 2198-H015-ERS are confirmed during quotation.

Allen-Bradley 2198-H015-ERS Kinetix 5500 Servo Drive Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • KTK-R-10 is documented for the 240 V single-phase input condition
  • KTK-R-15 is documented for the 240 V and 480 V three-phase conditions
  • Solid-state motor overload protection is integrated in the drive
  • DSL feedback and motor-temperature data use the documented single motor cable
  • Approved 2090 motor cables must match the selected motor and brake option
  • Shield clamps and connector hardware must follow the installation instructions
  • Controller and drive firmware levels must support the selected Logix motion configuration
  • Axis configuration is completed within the documented Studio 5000 environment
  • Installed firmware must be recorded before replacement or migration
  • Single-axis Logix-integrated motion using a Frame 2 Kinetix 5500 drive
  • 230 V single-phase or three-phase machines using the documented operating point
  • 480 V three-phase machines using the documented 3.2 kW operating point
Description
Allen-Bradley 2198-H015-ERS is a Frame 2 Kinetix 5500 Servo Drive for one Logix-integrated motion axis. It combines Integrated Motion over EtherNet/IP with hardwired Safe Torque Off.

The documented outputs are 1.0 kW at 230 V single-phase, 1.5 kW at 230 V three-phase, and 3.2 kW at 480 V three-phase. Output current is 5.0 A rms continuous and 12.5 A rms peak.

Confirm the actual supply, motor-feedback pair, brake interface, approved 2090 cable, controller and firmware, branch protection, regeneration, grounding, shield bonding, enclosure airflow, and hardwired safety circuit before installation or replacement.
Alternative Names
2198-H015-ERS 2198H015ERS 2198 H015 ERS Allen-Bradley 2198-H015-ERS Allen Bradley 2198-H015-ERS AB 2198-H015-ERS Rockwell Automation 2198-H015-ERS Kinetix 5500 2198-H015-ERS
Technical notes
Allen-Bradley 2198-H015-ERS supports three documented supply conditions; verify the selected operating point and complete motor-feedback-cable combination before commissioning.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can Allen-Bradley 2198-H015-ERS be used with a 230 V single-phase supply?
Yes. Rockwell documents a 195...264 V rms single-phase input condition with a 1.0 kW operating point. Motor sizing and branch protection must use that specific condition.
Which controller platforms are documented for Allen-Bradley 2198-H015-ERS?
Supported Kinetix 5500 systems are documented with ControlLogix 5570/5580, GuardLogix 5570, CompactLogix 5370, and Compact GuardLogix 5370 controller families.
What should be checked before ordering a motor cable for Allen-Bradley 2198-H015-ERS?
Match the motor catalog number, DSL feedback type, brake option, connector kit, approved 2090 cable catalog number and length to the documented combination.
How much enclosure depth is required for Allen-Bradley 2198-H015-ERS?
The installation instructions specify a minimum cabinet depth of 300 mm, together with upright mounting and the required airflow clearance.
Which protective fuse is documented for Allen-Bradley 2198-H015-ERS?
Rockwell lists KTK-R-10 for the 240 V single-phase condition and KTK-R-15 for the documented 240 V or 480 V three-phase conditions.
What must be preserved when migrating to Allen-Bradley 2198-H015-ERS?
Record the existing supply, motor and feedback catalog numbers, brake wiring, cable set, controller and firmware, axis scaling and tuning, load profile, regenerative duty, and safety validation.
What documentation should accompany an inquiry for Allen-Bradley 2198-H015-ERS?
Include the complete catalog number, clear nameplate images, installed supply, motor and feedback catalog numbers, controller family, cable details, required quantity and condition.