Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active

    Rockwell Automation currently lists Allen-Bradley 2198-S263-ERS4 as an Active Kinetix 5700 product. Verify the Series A hardware, compatible firmware, shared-bus components, lifting and connection hardware, and safety configuration before installation or replacement.

2198-S263-ERS4

/ 4.9
1001 reviews | Need a Specific Revision?
Allen-Bradley 2198-S263-ERS4 is a Kinetix 5700 single-axis inverter with 150 A rms continuous output, 263 A rms peak output, and Advanced Safety.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 2198-S263-ERS4
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2198-S263-ERS4

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2198-S263-ERS4
  • Product Family:
    Kinetix Servo Drive
  • Product Type:
    Kinetix 5700 Single Axis Inverter
  • Stock:
    1
  • Series:
    Kinetix 5700
  • DC Input Voltage:
    458...747 V DC
  • DC Input Current:
    164.0 A
  • Continuous Output Power:
    90.0 kW at 480 V rms three-phase
  • Continuous Output Current:
    150.0 A rms
  • Peak Output Current:
    263.0 A rms for 1.0 or 3.0 seconds
  • Continuous Output Current (0-pk):
    212.1 A
  • Peak Output Current (0-pk):
    371.9 A
  • Axis Configuration:
    Single axis
  • Internal Capacitance:
    2050 µF
  • PWM Frequency:
    4 kHz
  • Network:
    Integrated Motion over EtherNet/IP
  • Safety Option:
    ERS4 Advanced Safety
  • Weight:
    15.88 kg
  • Estimated shipping dimensions:
    22.0 × 47.8 × 25.2 cm
  • Tariff Code:
    8503009090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Connections Grounding Hardware Application
  • Single-axis inverter for a higher-current axis in a Kinetix 5700 shared DC-bus system
  • Two embedded RJ45 ports provide Integrated Motion over EtherNet/IP connectivity
  • ERS4 supports selection between Hardwired STO and Networked integrated safety modes
2198-S263-ERS4 provides one inverter axis within the modular Kinetix 5700 shared-bus architecture rather than acting as a standalone line-input drive.

The ERS4 Module Definition is available with drive firmware revision 9.001 or later and includes feedback configuration. Its Safety Application setting can be configured for Hardwired or Networked operation as documented by Rockwell Automation.

Confirm the selected bus supply, motor-feedback pair, bus and connector hardware, firmware, cabling, enclosure thermal design, grounding, lifting procedure, and validated safety architecture before commissioning.

Availability, condition, price, and shipping time for 2198-S263-ERS4 are confirmed during quotation.

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • DC-bus power and 24 V control power use their designated Kinetix 5700 connector points
  • Motor power, motor brake, and feedback wiring use the connector sets specified for the S263/S312 enclosure group
  • Integrated Motion over EtherNet/IP uses the two embedded RJ45 network ports
  • Protective-earth grounding is required at the designated chassis point
  • Ground-jumper position depends on the selected bus supply and AC source
  • The motor-cable shield must be bonded at the inverter cable clamp
  • Separate connectors are provided for DC-bus and 24 V control power
  • Motor power and motor brake use dedicated connection points
  • PORT1 and PORT2 provide standard RJ45 Ethernet connections
  • High-power servo axes in large custom machine applications
  • Shared DC-bus motion systems requiring a 220 mm axis module
  • Advanced Safety applications using compatible Logix safety control
Description
2198-S263-ERS4 is an Allen-Bradley Kinetix 5700 Single Axis Inverter for a higher-current servo axis in a shared DC-bus architecture. The ERS4 suffix denotes Advanced Safety.

The inverter provides 150.0 A rms continuous output and 263.0 A rms peak output at the documented 1.0- or 3.0-second durations, with 90.0 kW continuous output at 480 V rms three-phase.

Its 220 mm enclosure includes dedicated DC-bus, 24 V control-power, motor-power, feedback, network, and safety connection points. Verify lifting, bus hardware, motor cables, grounding, firmware, cooling, and safety commissioning.
Revisions

Revision Part #

Also known as

2198-S263-ERS4 Ser A
2198-S263-ERS4/A, Series A, Rev A
Alternative Names
2198-S263-ERS4 2198-S263ERS4 2198 S263 ERS4 2198S263ERS4 Allen-Bradley 2198-S263-ERS4 Allen Bradley 2198-S263-ERS4 AB 2198-S263-ERS4 Rockwell Automation 2198-S263-ERS4 Kinetix 5700 2198-S263-ERS4
Technical notes
For 2198-S263-ERS4, use the specified S263/S312 bus hardware and lifting points; verify motor-cable restrictions, shared-bus energy, firmware, cooling, grounding, and safety validation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What installation handling is required for Allen-Bradley 2198-S263-ERS4?
Rockwell Automation provides lifting points on the S263/S312 enclosure group. Use the official lifting and mounting instructions, confirm the mounting surface and clearances, and do not handle the module by its connectors or bus hardware.
Which bus connection hardware applies to Allen-Bradley 2198-S263-ERS4?
Use the connector and bus-bar components specified for the S263/S312 module group. Verify the selected DC-bus supply, adjacent module arrangement, control power, protective earth, and connector-kit catalog numbers before installation.
What motor-cable restriction should be checked for Allen-Bradley 2198-S263-ERS4?
The Kinetix cable data includes S263-specific limitations. Confirm the exact motor, feedback type, motor cable catalog number, conductor size, shield termination, brake wiring, and permitted cable length for the planned system.
How does the selected bus supply affect grounding of Allen-Bradley 2198-S263-ERS4?
Ground-jumper guidance depends on the AC source and whether the system uses a 2198-Pxxx DC-bus supply, 2198-RPxxx regenerative supply, or another active converter. Follow the matrix in publication 2198-UM002.
Can Allen-Bradley 2198-S263-ERS4 replace 2198-S263-ERS3 as a direct safety equivalent?
No automatic equivalence should be assumed. Compare ERS3 Integrated Safety with ERS4 Advanced Safety, then verify the Logix safety controller, drive firmware, safety functions, wiring, connector hardware, and validation procedure.
Which Rockwell Automation documents should be used for Allen-Bradley 2198-S263-ERS4?
Use publication KNX-TD003 for ratings and dimensions, publication 2198-UM002 for system installation and grounding, and the official Kinetix cable data for motor and feedback cable selection.
What should a buyer send when requesting Allen-Bradley 2198-S263-ERS4?
Send quantity, destination, required condition, bus-supply catalog number, motor and feedback details, load profile, controller and firmware, Advanced Safety requirements, cable and connector needs, and delivery target.