Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active
    Rockwell Automation lists 2198-C4030-ERS as an active Kinetix 5300 catalog number. Apter Power availability, condition, price, and shipping time are confirmed during quotation.

2198-C4030-ERS

/ 4.9
1001 reviews | Need a Specific Revision?
Allen-Bradley 2198-C4030-ERS is a Frame 2 Kinetix 5300 400 V-class Servo Drive rated 6.25 kW, 11.7 A rms continuous, and 34.1 A rms peak.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 2198-C4030-ERS
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2198-C4030-ERS

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2198-C4030-ERS
  • Product Family:
    Kinetix Servo Drive
  • Product Type:
    Servo Drive
  • Stock:
    1
  • Input Voltage:
    342...528 V rms three-phase
  • Frame Size:
    Frame 2
  • Continuous Output Power:
    6.25 kW at 480 V three-phase
  • Continuous Output Current:
    11.7 A rms
  • Peak Output Current:
    34.1 A rms
  • Network:
    Integrated Motion over EtherNet/IP
  • Safety Option:
    Standard hardwired Safe Torque Off (STO)
  • Weight:
    2.05 kg
  • Estimated shipping dimensions:
    5.5 × 22.5 × 26.5 cm
  • Tariff Code:
    8503009090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Performance Firmware Diagnostics Application

Features:

  • Frame 2 Kinetix 5300 400 V-class servo drive
  • 6.25 kW output at the documented 480 V three-phase condition
  • 11.7 A rms continuous and 34.1 A rms peak output current
Allen-Bradley 2198-C4030-ERS accepts 342...528 V rms three-phase input and provides Integrated Motion over EtherNet/IP with standard hardwired Safe Torque Off (STO).

Official design data documents Kinetix TLP rotary motor and Kinetix LDC linear motor combinations for this Frame 2 drive.

Confirm the motor or actuator torque-speed profile, cooling, feedback and brake interfaces, controller configuration, cable set, branch protection, axis duty, regeneration, and STO wiring before selection or migration.

Availability, condition, price, and shipping time for 2198-C4030-ERS are confirmed during quotation.
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Documented drive efficiency is 97%
  • Line-loss ride-through is specified as 20 ms
  • The internal shunt is rated 60 ohm and 50 W, with 775 V on and 765 V off thresholds
  • Kinetix 5300 firmware can be updated with ControlFLASH Plus or ControlFLASH software
  • Rockwell Automation recommends ControlFLASH Plus for drive firmware updates
  • 24 V control power must be present and the axis must be in an allowed non-running state before updating
  • Module and network status indicators are located below the four-character display
  • Module status identifies operational, standby, recoverable major-fault, and unrecoverable major-fault states
  • Network status identifies an established connection, connection timeout, or duplicate IP address
  • Rotary servo axes using documented TLP-B115-200, TLP-B145-250, or TLP-B200-300 combinations
  • Linear axes using documented LDC-C075400-DHT, LDC-C100300-DHT, or LDC-C100400-DHT combinations
  • Electronics assembly, packaging and converting, or printing and web machines after application-specific sizing
Description
2198-C4030-ERS is an Allen-Bradley Kinetix 5300 Frame 2 Servo Drive for 400 V-class single-axis motion applications.

It accepts 342...528 V rms three-phase input and delivers 6.25 kW at 480 V three-phase, with 11.7 A rms continuous output current and 34.1 A rms peak output current.

Integrated Motion over EtherNet/IP and standard hardwired Safe Torque Off (STO) support Logix-based machine designs. Confirm the motor or actuator torque-speed profile, feedback and brake interfaces, 24 V control load, cable set, branch protection, regeneration, controller configuration, grounding, and STO wiring before installation or migration.
Alternative Names
2198-C4030-ERS 2198-C4030ERS 2198 C4030 ERS 2198C4030ERS Allen-Bradley 2198-C4030-ERS Allen Bradley 2198-C4030-ERS AB 2198-C4030-ERS Rockwell Automation 2198-C4030-ERS Kinetix 5300 2198-C4030-ERS
Technical notes
Allen-Bradley 2198-C4030-ERS is a Frame 2 Kinetix 5300 Servo Drive with 6.25 kW output at 480 V three-phase, 11.7 A rms continuous output, and 34.1 A rms peak output. Verify the 342...528 V rms three-phase supply, motor or actuator torque-speed profile, 24 V control load, cable set, branch protection, regeneration, Logix configuration, grounding, and standard hardwired Safe Torque Off (STO) circuit before installation or migration.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What output ratings distinguish Allen-Bradley 2198-C4030-ERS within the 400 V-class Kinetix 5300 range?
Allen-Bradley 2198-C4030-ERS accepts 342...528 V rms three-phase input and provides 6.25 kW at 480 V three-phase. Its documented output ratings are 11.7 A rms continuous and 34.1 A rms peak for up to 1.0 second, in a Frame 2 enclosure.
Which Kinetix TLP motors are documented with Allen-Bradley 2198-C4030-ERS?
Rockwell Automation selection data includes TLP-B115-200, TLP-B145-250, and TLP-B200-300 motor combinations with Allen-Bradley 2198-C4030-ERS. Verify the exact motor winding, torque-speed profile, continuous and peak duty, feedback, brake, cable, and load requirements with the current design guide and Motion Analyzer.
Can Allen-Bradley 2198-C4030-ERS be selected for Kinetix LDC linear motor axes?
Yes, when the complete axis is sized and verified. The Kinetix 5300 design guide includes Allen-Bradley 2198-C4030-ERS performance curves with LDC-C075400-DHT, LDC-C100300-DHT, and LDC-C100400-DHT linear motors. Confirm the required force-speed curve, cooling method, feedback, cable length, duty cycle, and regeneration before selection.
What regeneration and internal-shunt data must be checked for Allen-Bradley 2198-C4030-ERS?
Rockwell Automation specifies a 60 ohm, 50 W internal shunt for Allen-Bradley 2198-C4030-ERS, with the shunt turning on at 775 V and off at 765 V. The drive has 560 microfarads of bus capacitance and 27.59 J of capacitive energy absorption. Use the actual axis inertia, deceleration profile, duty cycle, and regenerated energy to determine whether the internal shunt is sufficient.
What must be compared before using Allen-Bradley 2198-C4030-ERS in a Kinetix 350 migration?
Do not assume a drop-in replacement. Use Rockwell Automation publication 2198-RM005 to compare the 480 V three-phase supply, 6.25 kW and 11.7/34.1 A ratings, Frame 2 mounting, 24 V control power, motor and feedback interfaces, power and brake cables, Logix configuration, branch protection, and the standard hardwired Safe Torque Off (STO) circuit.
Which Rockwell Automation publications specify Allen-Bradley 2198-C4030-ERS?
Use KNX-TD003 for drive ratings, efficiency, shunt data, weight, and environmental specifications; 2198-IN021 for dimensions, mounting, wiring, and circuit protection; 2198-UM005 for configuration, startup, diagnostics, and standard hardwired Safe Torque Off (STO); KNX-RM012 for motor and actuator combinations; and 2198-RM005 for Kinetix 350 migration considerations.
What information should be included in a quotation request for Allen-Bradley 2198-C4030-ERS?
Provide the complete catalog number, quantity, destination, required condition, 480 V three-phase supply, motor or actuator catalog number, controller and Studio 5000 version, axis duty, regeneration profile, safety-circuit requirements, and required power, feedback, brake, or Ethernet cables. Apter Power will confirm availability, condition, price, and shipping time during quotation.