Allen-Bradley 1785-V40B is the 48K-word PLC-5/V40 VME controller for systems with up to 15 remote-I/O racks. Its four configurable DH+ or remote-I/O ports and lack of an extended-local I/O port distinguish it from 1785-V40L.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 1785-V40B
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 1785-V40B

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    1785-V40B
  • Product Family:
    PLC-5
  • Product Type:
    PLC-5/V40 VMEbus Processor
  • Stock:
    1
  • User Memory:
    48K words maximum
  • Total I/O Capacity:
    1,920 points in any mix
  • Complementary I/O Capacity:
    1,920 inputs and 1,920 outputs
  • Analog I/O Capacity:
    1,920 points maximum
  • DH+ or Remote I/O Ports:
    4
  • Remote I/O Racks:
    15 maximum
  • Remote I/O Chassis:
    60 maximum
  • RS-232 Ports:
    1
  • Remote I/O Transmission Rates:
    57.6, 115.2, and 230 kbps
  • Program Scan Time:
    0.5 ms per K word for bit logic; 2 ms per K word typical
  • Backplane Current:
    3.3 A maximum; 2.7 A typical
  • Extended-Local I/O Ports:
    None
  • Maximum Number of MCPs:
    16
  • Dimensions:
    4.1 × 18.8 × 26.2 cm
  • Weight:
    0.67 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals VMEbus Integration Channel Planning Project Recovery Application
  • 48K-word PLC-5/V40 controller for as many as 1,920 I/O points
  • Supports up to 15 remote-I/O racks and 60 remote chassis
  • Four DH+/remote-I/O ports, one RS-232 port and no extended-local I/O port

1785-V40B places PLC-5/V40 control functions in a VMEbus processor assembly.

Its A16 register space and A24 general-purpose memory interface let the VME host exchange status and application data with the controller.

A valid replacement must retain the remote-rack map, four channel assignments, link rates, VME addressing and battery-backed controller image.

Availability, condition, price, and shipping time for 1785-V40B are confirmed during quotation.

Allen-Bradley 1785-V40B PLC-5/V40 VMEbus Processor Manuals, Product Family, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Allocate A16 address space for 1785-V40B configuration and status registers
  • Reserve the required A24 space when general-purpose VME memory is used
  • Verify VME interrupt levels, slot position and backplane loading before startup
  • Map no more than 15 remote-I/O racks and 60 remote chassis to 1785-V40B
  • Record whether each of the four channels operates as DH+ or remote I/O
  • Preserve the selected 57.6, 115.2 or 230 kbit/s rate and the separate RS-232 setup
  • Archive the 1785-V40B program and all required data-table files before removal
  • Check the BATT indication and follow the documented 1770-WV/A battery procedure
  • Restore the VME allocation and prove every configured DH+ and remote-I/O path
  • PLC-5/VME systems requiring up to 48K words and 1,920 I/O points
  • Control architectures using as many as 15 remote-I/O racks without extended-local I/O
  • VME-hosted applications exchanging data through PLC-5/VME registers and memory
Description
Allen-Bradley 1785-V40B is the 48K-word PLC-5/VME controller that addresses as many as 1,920 I/O points.

Its VME interface uses A16 space for configuration and status registers and can use A24 space for general-purpose memory, while four independent ports can be assigned to Data Highway Plus or remote I/O.

This catalog has no extended-local I/O port. Replacement therefore depends on the installed VME allocation, 15-rack remote-I/O plan, channel rates, RS-232 settings and recovered PLC-5 application.
Alternative Names
1785-V40B Allen-Bradley 1785-V40B Rockwell Automation 1785-V40B PLC-5/V40 1785-V40B Allen-Bradley PLC-5/V40 1785-V40B PLC-5/40V 1785-V40B PLC-5 VME 1785-V40B
Technical notes
1785-V40B has no extended-local I/O port; replacement must preserve its A16/A24 VME allocation, 15-rack remote-I/O plan, four DH+/remote-I/O channel assignments, RS-232 settings, 57.6/115.2/230 kbit/s rates, and battery-backed PLC-5 project.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How can I distinguish Allen-Bradley 1785-V40B from 1785-V40L before ordering?
Confirm the full catalog number and installed port arrangement. The 1785-V40B is the PLC-5/V40 with four DH+ or remote-I/O ports, while 1785-V40L adds an extended-local I/O port and is not interchangeable by name alone.
Will a replacement Allen-Bradley 1785-V40B work in any VMEbus rack?
Not automatically. Verify the documented PLC-5/VME hardware environment, slot allocation, backplane power, address mapping, airflow, and application interface before installation.
What should be backed up before removing Allen-Bradley 1785-V40B?
Save the PLC-5 project, data tables, rack map, channel roles, node addresses, serial settings, firmware details, and any VME application dependencies.
Can Allen-Bradley 1785-V40B be replaced directly with 1785-V80B?
No. Memory, I/O capacity, rack limits, and application requirements differ, so conversion requires an engineering review and verified project compatibility.
Why can Allen-Bradley 1785-V40B load a project but leave field I/O inactive?
The restored project may not match the physical rack numbers, channel scanner or adapter roles, baud rates, node addresses, or remote-I/O cabling and termination.
What battery-related checks are important when replacing Allen-Bradley 1785-V40B?
Preserve the controller image before power removal, inspect the battery status indication, and follow the official procedure for the specified 1770-WV/A battery and memory retention.
What should be checked if Allen-Bradley 1785-V40B loses communication after replacement?
Compare all four channel assignments, network rates, rack and node settings, cabling, termination, RS-232 configuration, VMEbus seating, and the restored controller project with the original installation.