Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power coordinates official records, condition review, quotation, and large-panel migration checks.

2711P-T15C4D8

/ 4.9
1001 reviews | Need a Specific Revision?
For large-format operator stations, the discontinued 2711P-T15C4D8 provides a 15-inch XGA PanelView Plus 6 touch interface with modular networking.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 2711P-T15C4D8
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2711P-T15C4D8

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2711P-T15C4D8
  • Product Family:
    Panelview Plus
  • Product Type:
    PanelView Plus 6 1500 Touch Terminal
  • Stock:
    1
  • Display Size:
    15 in.
  • Display Resolution:
    1024 × 768 XGA
  • View Area:
    304 × 228 mm
  • Operator Input:
    8-wire analog resistive touch
  • Memory:
    512 MB RAM and 512 MB nonvolatile
  • User Memory:
    Approximately 79 MB
  • Communication Ports:
    Ethernet, RS-232, two USB host
  • External Storage:
    Hot-swappable SD and USB
  • Optional Network Interface:
    Ethernet, DH+, DH-485, or ControlNet module
  • Operating System:
    Windows CE 6.0 without extended features
  • Input Voltage:
    18...32 V DC
  • Power Consumption:
    70 W max; 39 W typical
  • Backlight:
    Field-replaceable CCFL, 50,000 h minimum
  • Enclosure Rating:
    NEMA/UL Type 12, 13, 4X; IP54/IP65
  • Weight:
    4.2 kg
  • Estimated shipping dimensions:
    33.0 × 41.6 × 6.5 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Panel Engineering Thermal Planning XGA Migration Product Applications

Features:

  • Large XGA interface: 15-inch 1024 × 768 resistive-touch display
  • Cabinet-impacting size: 330 × 416 × 65 mm terminal body
  • Mixed communication: standard Ethernet and RS-232 with optional modules
This 1500 touch model is the only product in this page group with a 1024 × 768 application canvas.

Its physical size, cutout, heat load, and operator reach make enclosure engineering central to a successful migration.

Discontinued status also increases the need to preserve the ME project and identify every rear module and field cable while the installed terminal remains accessible.

Apter Power supports 2711P-T15C4D8 enquiries with official-data checks, large-panel fit records, quotation, and sourcing coordination.

Verified resources for 2711P-T15C4D8:

Important Notice: Confirm the required application files, firmware, cables, accessories, and documentation in the quotation before ordering.
  • Cutout: use the official 305 × 391 mm opening as the retrofit baseline.
  • Rear depth: include the logic module, optional network hardware, and cable bends.
  • Support: assess panel stiffness for the larger terminal body.
  • Reach: confirm visibility and touch access across the full 15-inch surface.
  • DC demand: size the supply for the documented 70 W maximum load.
  • Heat: include the 240 BTU/hr terminal dissipation in enclosure calculations.
  • Ambient limit: maintain the official temperature range at the installed location.
  • Air path: avoid cable or component placement that traps heat behind the terminal.
  • Native project: retain or redesign the ME application for 1024 × 768.
  • Object placement: inspect pop-ups, alarm banners, trends, and numeric entry after conversion.
  • Data: export required recipes, alarm history, and removable-media files.
  • Acceptance: complete a production-task walkthrough before operator release.
  • Large process stations: present detailed XGA graphics for local supervision and control.
  • Complex machine HMIs: provide a broad touch surface for alarms, trends, and navigation.
  • Legacy modular networks: retain a documented communication module where installed architecture requires it.
Description
For large-format operator stations, 2711P-T15C4D8 provides a 15-inch 1024 × 768 XGA resistive-touch display on the modular PanelView Plus 6 1500 platform.

The direct Ethernet and RS-232 ports of 2711P-T15C4D8 can be supplemented by a documented communication module, while two USB hosts and SD storage support approved peripheral and recovery workflows.

Replacing 2711P-T15C4D8 requires a mechanical and thermal review of the 305 × 391 mm cutout, 70 W maximum DC load, application scaling, optional network, operator reach, and cabinet service space.
Alternative Names
Allen-Bradley 2711P T15C4D8 AB 2711PT15C4D8 PanelView Plus 6 1500 touch terminal 2711P T15C4D8 XGA HMI Rockwell 15-inch PVP6 terminal
Technical notes
The 2711P-T15C4D8 has a larger 330 × 416 × 65 mm body and 70 W maximum DC demand than smaller touch terminals. Reusing an existing enclosure plan without recalculating cutout support, rear clearance, cable bend, heat dissipation, power-supply capacity, and operator reach can create a mechanically sound-looking but unreliable retrofit.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What makes enclosure review critical for 2711P-T15C4D8?
Its 330 × 416 × 65 mm body, 305 × 391 mm cutout, rear module, cable bends, heat load, and operator reach all affect the retrofit.
How should power capacity be checked for 2711P-T15C4D8?
Measure the existing 24 V DC circuit under load and size wiring and supply capacity for the documented 70 W maximum, allowing for other cabinet loads.
Why can an application look smaller after migrating from 2711P-T15C4D8?
The source uses a 1024 × 768 XGA canvas. A target with different resolution or aspect ratio needs deliberate conversion rather than simple physical-size matching.
Which rear hardware must be recorded before removing 2711P-T15C4D8?
Photograph the logic module, optional communication module, SD card, USB peripherals, terminal block, Ethernet and serial cables, and every network label.
How should a successor proposed for 2711P-T15C4D8 be judged?
Compare cutout, resolution, project conversion, 24 V DC load, ports, optional network, service depth, and operator reach; do not treat the engineering replacement as a drop-in promise.
What should be included in a 2711P-T15C4D8 RFQ?
Provide complete label and rear photos, Series, firmware, ME backup, optional module, panel dimensions, quantity, destination, and outage schedule.

Product Browsing History