B&R X20AI8321 is a eight-channel differential current input module for 0 to 20 mA or 4 to 20 mA signals with 12-bit conversion for the X20 System.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for X20AI8321
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for X20AI8321

  • Manufacturer:
    B&R
  • Part Number:
    X20AI8321
  • Product Family:
    B&R X20 System
  • Product Type:
    Analog Current Input Module
  • Stock:
    1
  • Analog inputs:
    8 differential current inputs
  • Input ranges:
    0 to 20 mA or 4 to 20 mA
  • Digital converter resolution:
    12-bit
  • Conversion time:
    1 ms for all inputs
  • Input load:
    Less than 300 Ω
  • Permissible input signal:
    Maximum ±50 mA
  • Input filter:
    Third-order low-pass, 1 kHz cutoff
  • Common-mode range:
    ±12 V
  • Internal I/O power:
    1.37 W at Rev. D0 or later; 1.24 W before Rev. D0
  • Required terminal block:
    X20TB1F, ordered separately
  • Compatible bus modules:
    X20BM11 or X20BM15, ordered separately
  • Degree of protection:
    IP20
  • Operating temperature:
    -25 to 60 °C horizontal; -25 to 50 °C vertical
  • Dimensions:
    1.25 × 5.3 × 9.8 cm
  • Tariff Code:
    8538900000
  • Country of origin:
    Germany
  • Place of shipment:
    ​Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Loop Wiring Fault Handling Integration Application
  • Acquires eight 0 to 20 mA or 4 to 20 mA differential channels
  • Converts all inputs in one millisecond with 12-bit resolution
  • Includes reverse-polarity protection, supply-wiring protection, and channel diagnostics

X20AI8321 is a B&R analog current input module designed for X20 System I/O stations.

The module concentrates eight process-current loops in one X20 slice while isolating the channel group from the bus.

Before installation or replacement, verify the complete material number, 0 to 20 mA or 4 to 20 mA mode, external loop power, channel polarity, total wiring layout, common-mode voltage, scaling, hardware revision for power data, X20TB1F, X20BM11 or X20BM15, and fault handling.

Availability, condition, price, and shipping time for X20AI8321 are confirmed during quotation.

B&R X20AI8321 Analog Current Input Module Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • External transmitter or loop power is required where the field device needs it
  • Each current loop must be wired with correct polarity and common reference
  • The X20TB1F 16-pin terminal block is required for the eight-channel layout
  • Reverse-polarity protection helps protect incorrectly connected current loops
  • The controller can receive a configurable digital value during overload
  • Open-loop and under-range behavior should be defined in the application for 4 to 20 milliamp signals
  • The input group is isolated from the bus but channels are not isolated from one another
  • Hardware revision D0 changes the documented internal I/O power value
  • Scaling, alarms, and transmitter fault thresholds are configured in the controller project
  • Eight-channel 4 to 20 mA process-transmitter acquisition
  • High-density 0 to 20 mA measurement in distributed X20 I/O
  • Multi-sensor current-loop monitoring in machine and process-control stations
Description
X20AI8321 is a B&R analog current input module for the X20 System distributed I/O platform.

It acquires eight differential current channels in one millisecond, provides reverse-polarity and supply-wiring protection, and supports software-visible diagnostics.

Before installation or replacement, confirm the complete material number, 0 to 20 mA or 4 to 20 mA mode, external loop power, channel polarity, total wiring layout, common-mode voltage, scaling, hardware revision for power data, X20TB1F, X20BM11 or X20BM15, and fault handling.
Alternative Names
X20AI8321 X20 AI 8321 X20-AI8321 B&R X20AI8321 BR X20AI8321 B&R X20 AI 8321 X20 System X20AI8321
Technical notes
X20AI8321 concentrates eight current loops and requires external transmitter power; verify 0 to 20 or 4 to 20 mA scaling, polarity, common-mode range, hardware revision for power data, X20TB1F, and saved channel mapping before replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Does B&R X20AI8321 supply power to connected transmitters?
No transmitter supply is specified. Provide appropriate external loop power and verify the complete loop wiring and common reference.
How should a broken 4 to 20 mA loop be detected with B&R X20AI8321?
Configure scaling and under-range diagnostics in the controller so that a low current is distinguished from a legitimate process value.
Are all B&R X20AI8321 channels isolated from one another?
No. The eight-channel group is isolated from the bus, but individual channels are not isolated from each other.
Why should the hardware revision of B&R X20AI8321 be recorded?
B&R lists different internal I/O power values before and from revision D0, which can matter in station power calculations.
What should be checked when B&R X20AI8321 reports overload?
Inspect loop polarity, transmitter supply, current level, common-mode voltage, terminal mapping, shorts, and configured overload behavior.
Which terminal block is required for B&R X20AI8321?
Use the documented X20TB1F 16-pin terminal block with a compatible X20BM11 or X20BM15 bus module.
What should be saved before replacing B&R X20AI8321?
Record hardware revision, channel ranges, loop supplies, polarity, scaling, alarm thresholds, terminal mapping, accessories, and Automation Studio configuration.