Features:
- Controller supply: Feeds the X20 bus controller and X2X Link in the station.
- Separate I/O input: Internal I/O power uses its own defined 24 VDC feed.
- Service visibility: Module status and RS232 transfer have local indicators.
The X20PS9400 is used together with an X20 bus controller as part of the station supply arrangement.
Its controller/X2X and I/O power paths serve different loads, so the station design can account for each feed on its own terms.
B&R specifies a suitable X20BB8x bus base and the X20TB12 terminal block as separate accessories for the installed assembly.
Apter Power can provide quotations, technical documentation, and configuration support for the B&R X20PS9400 Isolated Bus Controller Power Supply Module.
B&R X20PS9400 Isolated Bus Controller Power Supply Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- BC/X2X fuse: The controller-side input has an integrated, non-replaceable fuse within the module.
- BC/X2X polarity: Reverse-polarity protection is provided on this input, unlike the I/O feed.
- I/O line protection: The separate I/O input requires a slow-blow line fuse rated no higher than 10 A.
- I/O polarity: The I/O input has no reverse-polarity protection, a distinct wiring consideration for this feed.
- Standard base: X20BB80 accommodates the bus-controller base module and the associated power-supply module.
- One-slot expansion: X20BB81 provides one additional X20 add-on position beside the controller and supply.
- Two-slot expansion: X20BB82 provides two add-on positions, making base choice relevant to the station layout.
- Keyed terminal: X20TB12 is the separate 12-pin, 24 VDC keyed terminal block for this module.
- Mounting temperature: Horizontal and vertical installation are both permitted, but vertical mounting has a lower ambient-temperature ceiling.
- High elevation: Above 2,000 m, the permitted ambient temperature decreases by 0.5°C per 100 m.
- Humidity: Operation is specified at 5–95% relative humidity without condensation, a boundary for cabinet conditions.
- Module protection: IP20 is the stated protection degree, so the installation environment remains part of cabinet planning.
- X20 controller stations: The module is used together with an X20 bus controller in the station assembly.
- X2X Link supply: The same station module provides the controller-side X2X Link feed.
- Internal I/O supply: It also provides the local I/O power path through its separate I/O input.
- Redundant BC/X2X layouts: Multiple supply modules can operate simultaneously for this controller-side supply path.