Technical specifications for X67BC8331

  • Manufacturer:
    B&R
  • Part Number:
    X67BC8331
  • Product Family:
    B&R X67 System
  • Product Type:
    POWERLINK Bus Controller with Integrated Digital I/O
  • Stock:
    1
  • Fieldbus:
    POWERLINK V1/V2 controlled node, type 2
  • Fieldbus physical layer:
    100BASE-TX, M12 D-coded
  • Transfer rate:
    100 Mbit/s
  • Maximum segment length:
    100 m
  • Minimum POWERLINK / X2X cycle:
    200 µs / 200 µs
  • X2X Link expansion:
    Up to 250 additional modules
  • Configurable digital channels:
    8 inputs or outputs
  • Input type:
    24 VDC, sink, EN 61131-2 type 1
  • Output type:
    24 VDC, source FET
  • Nominal output current:
    2 A per channel; 8 A total
  • Sensor / actuator supply:
    0.5 A total, short-circuit protected
  • X2X Link power output:
    3 W
  • Supply voltage:
    24 VDC nominal, 18 to 30 VDC
  • Operating temperature:
    -25 to 60 °C
  • Degree of protection:
    IP67
  • Storage / transport temperature:
    -40 to 85 °C
  • Dimensions:
    5.3 × 8.5 × 4.2 cm
  • Weight:
    0.2 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Network Local I/O Expansion Application
  • Couples X67 and X2X Link I/O to POWERLINK
  • Provides eight local channels configurable as inputs or outputs
  • Supports synchronous fieldbus and X2X operation from a 200 microsecond cycle

X67BC8331 is a B&R powerlink bus controller with integrated digital i/o designed for the X67 System.

The controller couples distributed X67 and X2X Link I/O to POWERLINK while providing local field I/O and a 3 W X2X power output.

Before installation or replacement, verify the complete material number, the POWERLINK node and cycle configuration, D-coded M12 Ethernet wiring, channel directions, 8 A total output current, X2X power budget, firmware, Automation Studio project and sealed connector condition.

Availability, condition, price, and shipping time for X67BC8331 are confirmed during quotation.

B&R X67BC8331 POWERLINK Bus Controller with Integrated Digital I/O Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • POWERLINK uses a D-coded M12 100BASE-TX connection
  • Dynamic node allocation is supported
  • POWERLINK and X2X cycles can be synchronized using the documented prescaler
  • Eight M8 channels are configured individually as inputs or outputs
  • Input filters are software-configurable from 0 to 25 ms
  • Output monitoring reports channel faults after the documented diagnostic delay
  • The integrated X2X connection supports up to 250 additional modules
  • The controller provides 3 W of X2X Link power
  • The complete expansion power and cycle-time budget must be calculated
  • POWERLINK-connected distributed machine I/O stations
  • IP67 local sensor and actuator control with integrated configurable channels
  • Expansion of field-mounted X67 stations through additional X2X Link I/O
Description
X67BC8331 is a B&R powerlink bus controller with integrated digital i/o for the X67 System.

It provides 100 Mbit/s POWERLINK with a 200 µs minimum cycle, eight software-configurable 24 VDC input or 2 A output channels, and X2X Link expansion for up to 250 additional modules.

Before installation or replacement, confirm the complete material number, the POWERLINK node and cycle configuration, D-coded M12 Ethernet wiring, channel directions, 8 A total output current, X2X power budget, firmware, Automation Studio project and sealed connector condition.
Alternative Names
X67BC8331 X67 BC8331 B&R X67BC8331 B&R X67 BC8331 BR X67BC8331 B&R X67 System X67BC8331 X67 System X67BC8331
Technical notes
X67BC8331 combines a POWERLINK controlled node with local configurable I/O. Back up the node, channel and X2X configuration, then verify network timing, 24 VDC load, firmware, connector coding and IP67 sealing before replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What should be backed up before replacing B&R X67BC8331?
Save the Automation Studio hardware tree, POWERLINK node settings, cycle and prescaler, channel directions, I/O mapping, X2X module order, firmware and active diagnostics.
Why can B&R X67BC8331 appear on POWERLINK but exchange no process data?
Compare node assignment, configured and actual module order, cycle settings, process-image lengths, firmware, cable and the managing controller state.
Can all B&R X67BC8331 output channels carry 2 A simultaneously?
The official total nominal output current is 8 A, so calculate channel current, inrush, duty cycle, ambient temperature and field-power wiring rather than multiplying eight by 2 A.
How many expansion modules can B&R X67BC8331 support?
The official description permits up to 250 additional X2X Link modules, subject to the 3 W power budget, topology, cycle time and project limits.
What should be checked if B&R X67BC8331 reports intermittent network errors?
Inspect D-coded M12 cables, connector sealing, shield and grounding, segment length, node configuration, supply stability, cycle load and POWERLINK diagnostics.
Can B&R X67BC8331 be replaced by another X67 POWERLINK controller without project changes?
Do not assume so. Compare node type, integrated I/O mapping, X2X power, channel ratings, connector layout, firmware and project hardware definition.
What is required to retain IP67 protection on B&R X67BC8331?
Use compatible sealed M8 and M12 connectors, cap every unused port, apply the documented connector torque and inspect seals, housing and cable jackets.