Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com

X67AO1223

/ 4.9
1001 reviews | Need a Specific Revision?
B&R X67AO1223 is an IP67 X67 analog output module with four ±10 V channels and 12-bit conversion for the X67 System.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for X67AO1223
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for X67AO1223

  • Manufacturer:
    B&R
  • Part Number:
    X67AO1223
  • Product Family:
    B&R X67 System
  • Product Type:
    4-channel ±10 V Analog Output Module
  • Stock:
    1
  • Analog outputs:
    4 voltage channels
  • Output range:
    ±10 V
  • Resolution:
    12-bit
  • Update time:
    400 µs for all outputs
  • Settling time:
    Approximately 1 ms for the full range
  • Maximum output current:
    ±10 mA per channel
  • Minimum load resistance:
    1 kΩ
  • Short-circuit current:
    ±40 mA
  • Output filter:
    First-order low-pass, 2.5 kHz
  • Gain error:
    0.15%
  • Offset error:
    0.05%
  • Nonlinearity:
    <0.15%
  • Output protection:
    Short-circuit protection and supply-wiring protection
  • Output enable:
    Integrated relay
  • Internal I/O / X2X power:
    4 W / 0.75 W
  • Degree of protection:
    IP67
  • Operating temperature:
    -25 to 60 °C
  • Storage / transport temperature:
    -40 to 85 °C
  • Dimensions:
    5.3 × 8.5 × 4.2 cm
  • Output connectors:
    4 × M12, A-coded
  • Weight:
    0.19 kg
  • Tariff Code:
    8538900000
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Load Compatibility Command Behavior Installation Application
  • Generates four ±10 V analog command signals
  • Updates all outputs in 400 microseconds
  • Provides IP67 setpoint delivery close to drives and actuators

X67AO1223 is a B&R 4-channel ±10 v analog output module designed for the X67 System.

The module sends distributed analog command and setpoint signals to drives, valves and other voltage-controlled devices.

Before installation or replacement, verify the complete material number, the ±10 V receiving device, load resistance, reference and shielding, M12 A-coded output pinout, power-up and error-state behavior, project scaling, cable route and IP67 sealing.

Availability, condition, price, and shipping time for X67AO1223 are confirmed during quotation.

B&R X67AO1223 4-channel ±10 V Analog Output Module Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Each receiving input should be at least 1 kilohm
  • Output current is limited to ±10 milliamperes per channel
  • Reference and grounding must prevent unwanted common-current paths
  • The controller project defines engineering scaling and limits
  • Power-up, communication-loss and disabled-output behavior must be tested
  • Approximately 1 millisecond is required for a full-range settling step
  • Analog cables should be separated from high-current switching conductors
  • Shield termination should follow the machine EMC plan
  • Compatible sealed connectors and caps maintain IP67 protection
  • Distributed ±10 V speed or torque commands for drives
  • Voltage setpoints for proportional valves and actuators
  • IP67 analog reference generation near machine mechanisms
Description
X67AO1223 is a B&R 4-channel ±10 v analog output module for the X67 System.

It updates all channels in 400 µs, settles across the full range in approximately 1 ms and can source up to ±10 mA per channel into loads of at least 1 kΩ.

Before installation or replacement, confirm the complete material number, the ±10 V receiving device, load resistance, reference and shielding, M8 pinout, power-up and error-state behavior, project scaling, cable route and IP67 sealing.
Alternative Names
X67AO1223 X67 AO1223 B&R X67AO1223 B&R X67 AO1223 BR X67AO1223 B&R X67 System X67AO1223 X67 System X67AO1223
Technical notes
X67AO1223 generates four ±10 V signals. Verify the receiving-device input resistance, reference, scaling, cable shielding, power-up and fault-state behavior, connector pinout and sealed installation before enabling motion or process loads.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can B&R X67AO1223 drive a load below 1 kΩ?
No. The receiving input should meet the documented minimum 1 kΩ load resistance and the channel must remain within the ±10 mA output limit.
What should happen to B&R X67AO1223 outputs if X2X communication is lost?
The result depends on the configured output and application behavior; test the required safe or retained state during commissioning rather than assuming it.
Why does a B&R X67AO1223 output not reach the commanded voltage?
Check load resistance, short circuit, wiring polarity, common reference, supply, connector condition, project scaling, output enable and raw command limits.
Can B&R X67AO1223 directly drive a 4–20 mA device?
No. Use a suitable current-output module or approved converter; this module provides ±10 V outputs.
How fast does B&R X67AO1223 settle after a full-scale step?
The official value is approximately 1 ms for the full range, in addition to controller and X2X update timing.
Can B&R X67AO1223 be used for a safety-related analog command?
Not as the safety element. Risk reduction requires a separately validated safety architecture capable of forcing and monitoring the required safe state.
What should be recorded before replacing B&R X67AO1223?
Record scaling and limits, power-up and fault behavior, connector labels, load resistance, reference and shielding, X2X position and output calibration results.