Features:
- Uses the smooth 1.99-inch side-exit case for sliding-bracket installations.
- Includes a 1.0 m high-temperature FluidLoc probe cable without armor.
- Provides the 27.9 mm measurement span of the matching 3300 XL 50 mm system.
The current ordering configuration is 330876-03-10-00-00, combining the smooth side-exit case, 1.0 m total length, unarmored FluidLoc cable and no agency approval option.
In service, the probe observes large axial movement at a collar or ramp and supplies the gap-dependent signal used by the matching 3300 XL 50 mm Proximitor Sensor.
Before installation, verify side-exit clearance, bracket orientation, target size, cable route, system electrical length and the absence of a hazardous-area approval requirement.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Bently Nevada 330876-03-10-00-00:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Measures differential expansion between a turbine rotor and casing over an extended linear span.
- Supports complementary transducer arrangements on opposite sides of an expansion collar.
- Fits sliding-bracket verification layouts where a side-exit cable avoids the axial mounting path.
- The two rear 1/4-20 mounting holes secure the smooth case to the applicable probe clamp or bracket.
- The cable collar may be removed temporarily to route the lead through restricted clearances.
- Initial and periodic movement checks should sweep the probe through the required measurement range.
- The matched 50 mm system provides a 27.9 mm linear range beginning approximately 1.3 mm from the target.
- Nominal scale factor is 0.394 V/mm when calibrated to the documented AISI 4140 target.
- System specifications apply with the matching sensor, extension cable, supply and load conditions.
- The probe supports continuous operation to 200 C and intermittent exposure to 250 C.
- Front and rear seals combine with FluidLoc construction to limit moisture entry into the probe tip.
- Connector protectors should remain clean and installed to preserve signal integrity in turbine environments.