Features:
- Combines CSA, ATEX, and IECEx agency coverage in the option-02 ordering configuration.
- Provides up to 35 V back-power immunity when an external source rises above the adjusted output voltage.
- Supports standard DIN-rail mounting or side-wall mounting inside a flat control panel.
The current ordering configuration is 60X/XPS01-02, the multi-certified 240 W supply specified for an Orbit 60 3U chassis.
Its regulated output supports continuous control-system loading and a timed 150% peak mode, with overload shutdown followed by automatic restart after the defined delay.
For integration, retain the 02 approval code, assess the application fuse, preserve natural-convection airflow, and confirm ambient-temperature derating for the selected hazardous-area certification.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Bently Nevada 60X/XPS01-02:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Feeds an Orbit 60 3U rack installed where a multi-approval supply configuration is required.
- Accepts plant DC distribution from 100–250 VDC when an AC branch is unavailable in the monitoring cabinet.
- Enables cabinet alarm wiring through the power-OK relay so loss of regulated output can be annunciated remotely.
- Input-related output variation is limited to 0.1 percent under the stated conditions, supporting stable voltage as the source changes.
- Load-related output variation remains within 0.5 percent across the documented operating range of the regulated supply.
- Ripple and noise are held within 100 mV peak-to-peak over the specified measurement bandwidth.
- Natural-convection cooling supports operation from -40 to +70 degrees Celsius when airflow and derating requirements are met.
- Continuous and peak output must be reduced above 60 degrees Celsius according to the separate high-temperature derating rates.
- Installation limits include 2,000 m altitude, Pollution Degree 2 and up to 95 percent non-condensing humidity.
- The -02 suffix carries the combined CSA, ATEX and IECEx approval package for the 240 W supply configuration.
- Certified use remains tied to the exact product label, enclosure conditions and wiring practices stated for the installation.
- The documented IEC and EN safety and EMC requirements apply without changing the supply into a separately SIL-certified protection component.