Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotation, documentation, and configuration checks for KJ3102X1-BE1.

KJ3102X1-BE1

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson KJ3102X1-BE1 is a DeltaV eight-channel intrinsically safe HART analog output module for controlled signals to hazardous-area field devices.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for KJ3102X1-BE1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for KJ3102X1-BE1

  • Manufacturer:
    Emerson
  • Part Number:
    KJ3102X1-BE1
  • Product Family:
    DeltaV
  • Product Type:
    Intrinsically Safe Analog Output Module
  • Stock:
    1
  • Output Channels:
    8
  • Nominal Signal Range:
    4 to 20 mA
  • Full Signal Range:
    1 to 22 mA
  • LocalBus-to-Channel Isolation:
    60 VAC
  • Channel-to-Channel Isolation:
    None
  • I.S. Channel-to-Non-I.S. Rail Isolation:
    250 VAC
  • LocalBus Current:
    630 mA typical at 12 VDC nominal
  • Open-Circuit Detection Threshold:
    0.7 mA ±0.2 mA
  • Resolution:
    12 bits
  • Calibration:
    None required
  • Optional Loop Disconnect:
    Yes
  • Minimum Load Voltage:
    13 V at 20 mA
  • Maximum Load Resistance:
    650 Ω
  • Temperature Stability:
    ±0.006% of span per °C
  • Intrinsic Safety Output Voltage:
    Uo 24.6 V
  • Intrinsic Safety Output Current:
    Io 93 mA
  • Intrinsic Safety Output Power:
    Po 0.57 W
  • Operating Temperature:
    -40 to 60 °C (-40 to 140 °F)
  • Storage Temperature:
    -40 to 85 °C (-40 to 185 °F)
  • Relative Humidity:
    5 to 95%, non-condensing
  • Airborne Contaminants:
    ISA-S71.04-1985 Class G3; conformal coating
  • Protection Rating:
    IP20
  • I/O Interface Hazardous Location:
    Zone 2 IIC T4; Class I, Division 2, Groups A-D, T4
  • Field-Circuit Hazardous Location:
    Zone 0 IIC; Class I, Division 1, Groups A-D
  • Shock:
    10 g half-sine wave for 11 ms
  • Vibration:
    1 mm peak-to-peak from 5 to 16 Hz; 0.5 g from 16 to 150 Hz
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Certifications Environmental Process Control

Features:

  • Provides eight HART analog output channels for intrinsically safe control circuits.
  • Publishes entity limits of Uo 24.6 V, Io 93 mA, and Po 0.57 W for connected loads.
  • Interfaces compatible hazardous-area field devices with DeltaV M-series control hardware.
The current ordering configuration is KJ3102X1-BE1, an eight-channel DeltaV M-series intrinsically safe HART analog output module.

It delivers controlled analog outputs and HART communication to compatible hazardous-area field devices through the approved intrinsic-safety I/O assembly.

Before installation, confirm the carrier, terminal keying, cable parameters, loads and intrinsic-safety entity calculation for each loop.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson KJ3102X1-BE1:

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Drives compatible intrinsically safe valve positioners and analog field devices in hazardous areas.
  • Provides HART communication on approved analog output loops for configuration and maintenance.
  • Supports multi-channel analog control where the installed field circuit requires energy limitation.
  • The documented intrinsic-safety output parameters are Uo 24.6 V, Io 93 mA, and Po 0.57 W.
  • Connected equipment and cable entity parameters must satisfy the approved hazardous-area loop calculation.
  • Use only the carrier, terminal hardware, and installation arrangement covered by the project certification records.
  • Operates as part of an approved DeltaV intrinsic-safety installation in the documented hazardous-area system.
  • Requires ambient, enclosure, and wiring conditions to remain within the project approval limits.
  • Depends on the approved carrier and terminal hardware to maintain the certified installation arrangement.
  • Delivers controlled analog outputs to eight compatible field loops.
  • Provides HART digital communication alongside the primary analog control signal.
  • Supports DeltaV process strategies that command approved hazardous-area actuators and positioners.
Description
The current ordering configuration is KJ3102X1-BE1, the Emerson DeltaV Intrinsically Safe Analog Output Module. Retain the complete model and suffix when preparing maintenance records, spare-part requests, and replacement checks.

This configuration provides eight-channel intrinsically safe HART analog output module for approved hazardous-area field-device circuits. The documented product data identifies output channels as 8 HART analog outputs and intrinsic safety output voltage as Uo 24.6 V for the selected hardware.

Before installation or substitution, verify the signal range and loop-power method, polarity, shielding and terminal hardware, and channel scaling and project assignments. Compare the nameplate and project documentation with the exact KJ3102X1-BE1 configuration before the equipment is energized.
Alternative Names
KJ3102X1-BE1 KJ3102X1 BE1 KJ3102X1BE1 Emerson KJ3102X1-BE1 DeltaV KJ3102X1-BE1 EMR KJ3102X1-BE1
Technical notes
For KJ3102X1-BE1, verify Uo, Io, Po, cable capacitance, load voltage, and field-device entity limits before connecting hazardous-area output loops.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What intrinsic-safety source ratings apply to KJ3102X1-BE1 outputs?
KJ3102X1-BE1 has documented entity values of Uo 24.6 V, Io 93 mA and Po 0.57 W across eight HART analog output channels.
Which actuator data determines KJ3102X1-BE1 compatibility?
Validate the I/P converter or positioner entity parameters, loop load, cable capacitance and inductance, terminal block and control drawing.
Where does KJ3102X1-BE1 serve a hazardous process loop?
It sends intrinsically safe 4-20 mA HART commands to compatible final-control devices in an engineered DeltaV system.
How should the exact KJ3102X1-BE1 supply configuration be confirmed?
Match the BE1 output designation, approval markings, hardware revision, connector condition and traceability to the installed bill of material.
What prevents an input card from replacing KJ3102X1-BE1?
The replacement must be an analog output with equivalent sourcing behavior, entity limits, HART support, keying and project configuration.
Which loop documents support a KJ3102X1-BE1 price request?
Provide the hazardous-area control drawing, positioner or I/P data, cable parameters, required certificates, quantity and shipping destination.