SE4006P2

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson SE4006P2 is the DeltaV Simplex Serial Interface with Two Ports and Termination Block. In the documented architecture, it connects serial field equipment through two independently configurable ports.
In Stock
Fast Shipping Available
Get a quick price for SE4006P2
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for SE4006P2

  • Manufacturer:
    Emerson
  • Part Number:
    SE4006P2
  • Product Family:
    DeltaV
  • Product Type:
    DeltaV Simplex Serial Interface with Two Ports and Termination Block
  • Stock:
    1
  • Serial Ports:
    2
  • Interface Modes:
    RS-232 and RS-422/485
  • Datasets:
    32 total, 16 per port
  • Baud Rate:
    300 to 115200
  • Parity:
    Even, odd, or none
  • Data Bits:
    7 or 8
  • Stop Bits:
    1 or 2
  • Assembly:
    Interface and termination block
  • Tariff Code:
    Please confirm the destination before shipping.
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Communication Configuration Installation

Features:

  • SE4006P2 provides two independently configurable serial ports for supported device communications.
  • Each port supports RS-232 or RS-422/485 operation in the documented electrical interface modes.
  • The interface handles 32 datasets in total, with a maximum of 16 datasets assigned to each port.
The current ordering configuration is SE4006P2, the DeltaV Simplex Serial Interface with Two Ports and Termination Block identified for the DeltaV S-series Serial Interface.

SE4006P2 performs the documented S-series simplex two-port serial interface assembly function within the DeltaV S-series Serial Interface architecture. Its operation follows the capabilities and limits assigned to this exact ordering configuration.

Before commissioning, match each port's electrical mode, retain the correct termination block and wiring, and validate protocol timing and dataset mapping.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson SE4006P2:Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Connect serial devices that exchange data with DeltaV through the documented two-port S-series interface.
  • Integrate Modbus-compatible packaged equipment through independently configurable RS-232 or RS-422/485 serial links.
  • Exchange up to 32 datasets across two serial ports, with a documented limit of 16 datasets per port.
  • Configure SE4006P2 only with the protocol and interface parameters documented for its S-series simplex two-port serial interface assembly.
  • SE4006P2 supports RS-232 and RS-422/485 physical interface modes for its documented communication ports.
  • SE4006P2 supports 1 or 2 stop bits, which must match the communication settings of the attached device.
  • SE4006P2 permits 7 or 8 data bits per serial character in the documented port configuration.
  • Validate protocol timing and dataset mapping before commissioning the documented S-series simplex two-port serial interface assembly configuration. Confirm the completed work before placing SE4006P2 in service.
  • Configure SE4006P2 with the settings and hardware keying specified for its S-series simplex two-port serial interface assembly.
  • Install SE4006P2 only with the carrier, terminal, and field-wiring components documented for this S-series simplex two-port serial interface assembly.
  • For SE4006P2's S-series simplex two-port serial interface assembly installation, verify keying, circuit ratings, matched field hardware, and power isolation before connection.
  • The documented SE4006P2 assembly consists of Interface and termination block.
Description
SE4006P2 is the DeltaV Simplex Serial Interface with Two Ports and Termination Block. This exact ordering configuration is documented for the DeltaV S-series Serial Interface family.

In service, SE4006P2 connects serial field equipment through two independently configurable ports. Typical use includes serial analyzer and package-unit integration and independent communication with two serial devices.

Before selection or installation, match each port's electrical mode, retain the correct termination block and wiring, and validate protocol timing and dataset mapping.
Alternative Names
SE4006P2 Emerson S-series Serial Interface Card Emerson 2-Port Serial Interface Emerson SE4006P2 DeltaV SE4006P2 EMR SE4006P2 SE 4006P2 SE-4006P2
Technical notes
SE4006P2 identifies one simplex interface supplied with its termination block; match the complete ordering code and installed DeltaV architecture before substitution.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Does SE4006P2 include both the two-port serial interface and its termination block?
It is the DeltaV Simplex Serial Interface with Two Ports and Termination Block; this ordering configuration connects serial field equipment through two independently configurable ports.
Is SE4006P2 supplied as a simplex serial-interface assembly?
The official order identifies one simplex interface supplied with its termination block.
Can SE4006P2 integrate serial analyzers and package-unit controls?
For SE4006P2, a documented use is serial analyzer and package-unit integration.
Which RS-232 or RS-422/485 port mode must match before sourcing SE4006P2?
Confirm the exact model, match each port's electrical mode, and the installed DeltaV S-series Serial Interface architecture.
Why must termination wiring and dataset mapping be retained when commissioning SE4006P2?
Before commissioning, retain the correct termination block and wiring and validate protocol timing and dataset mapping.
How is the SE4006P2 assembly identified in official documentation?
For SE4006P2, the official documentation states Assembly as Interface and termination block.