5302-MBP-MCM4

/ 4.9
1001 reviews | Need a Specific Revision?
ProSoft 5302-MBP-MCM4 is a Modbus Plus to Modbus master/slave gateway that connects Modbus Plus networks with Modbus serial devices through one Modbus Plus port and up to four configurable serial ports.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 5302-MBP-MCM4
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 5302-MBP-MCM4

  • Manufacturer:
    ProSoft
  • Part Number:
    5302-MBP-MCM4
  • Product Family:
    ProSoft
  • Product Type:
    Modbus Plus to Modbus Master/Slave Gateway
  • Stock:
    1
  • Power Supply:
    24 VDC nominal; 18 to 36 VDC allowed; Positive, Negative, GND Terminals; 2.5 mm screwdriver blade.
  • Current Load:
    500 mA max@ 24 VDC
  • Operating Temperature:
    –20 to 50°C (–4 to 122°F)
  • Storage Temperature:
    –40 to 85°C (–40 to 185°F)
  • Relative Humidity:
    5 to 95% (non-condensing)
  • LED Indicators:
    Power and Module Status, Application Status, Serial Port Activity LED, Serial Activity and Error LED Status.
  • Configuration Serial Port:
    DB-9M RS-232 only, No hardware handshaking.
  • Baud Rate:
    110 to 115K baud
  • Stop Bits:
    1 or 2
  • Data Size:
    7 or 8 bits
  • Parity:
    None, Even, Odd
  • RTS Timing delays:
    0 to 65535 ms
  • Node address:
    1 to 247 – software selectable
  • Error Checking:
    RTU mode (binary) with CRC-16, ASCII mode with LRC error checking.
  • Ethernet Port (Ethernet modules only):
    RJ45 Connector, Link and Activity LED indicators.
  • Application Serial Ports:
    RS-232/422/485, RS-232 handshaking configurable, RS-422/485 screw termination included.
  • Weight:
    0.65 kg
  • Estimated shipping dimensions:
    7x13.5x13.1cm
  • Tariff Code:
    8517623300
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Application Scenarios Connection Configuration

Features:

  • Connects one Modbus Plus interface with up to four Modbus serial ports while supporting master and slave operation on both protocols.
  • Offers individually configurable RS-232, RS-422, and RS-485 communication with flexible baud rate, parity, data size, stop bit, node address, and RTS timing settings.
  • Combines stand-alone DIN-rail installation with 24 VDC power, communication status indicators, RTU and ASCII support, and industrial environmental ratings.
ProSoft 5302-MBP-MCM4 provides an integration point for industrial installations where Modbus Plus networks and Modbus serial equipment must operate together. Existing plants may contain controllers, field equipment, and serial devices using different communication interfaces, making a dedicated protocol gateway useful for maintaining data exchange across the system. One Modbus Plus connection and up to four serial channels allow multiple communication paths to be coordinated through a stand-alone unit. Master and slave capabilities provide flexibility when assigning communication responsibilities. The DIN-rail format also supports installation within industrial control cabinets without requiring a dedicated PLC rack slot.

Communication flexibility is a key application value of ProSoft 5302-MBP-MCM4. Individual serial ports can be configured for RS-232, RS-422, or RS-485 operation to accommodate different Modbus devices. Adjustable baud rate, parity, data size, stop bits, node addressing, and RTS timing allow communication settings to be matched to connected equipment. RTU communication uses CRC-16 error checking, while ASCII communication uses LRC error checking. Such configuration options make the gateway suitable for networks containing serial devices with different communication requirements.

ProSoft 5302-MBP-MCM4 can be applied across manufacturing, oil and gas, electrical power, and food processing environments where protocol integration is part of the control architecture. Operation from -20 to 50°C and storage from -40 to 85°C support typical industrial installation and storage conditions. Relative humidity can range from 5% to 95% when condensation is prevented. Dedicated LEDs provide immediate information about power, module operation, application status, serial activity, and communication errors. Combined with the 18 to 36 VDC input range, the gateway provides a practical interface for distributed Modbus Plus and Modbus communication systems.

The 5302-MBP-MCM4 ProSoft Modbus Plus to Modbus Master/Slave Gateway may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
ProSoft 5302-MBP-MCM4 Modbus Plus to Modbus Master/Slave Gateway Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ProSoft 5302-MBP-MCM4 Modbus Plus to Modbus Master/Slave Gateway Specs

General

  • Manufacturer ProSoft
  • Model 5302-MBP-MCM4
  • Condition New Original ready stock
  • Product Family 5302-MBP-ASCII4,5302-MBP-DFCM4,5301-MBP-MCM
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Multi-Device Group Control: Suitable for simultaneously polling multiple frequency converters or power meters via four RS-485 serial ports and aggregating the data to a Schneider PLC.
  • Smooth Network Bridging: Used for low-cost expansion to introduce new serial port devices without changing the existing Modbus Plus control layer network.
  • Heterogeneous System Swapping: Deployed in upgrade projects that require direct connection of Modbus serial touchscreens (HMIs) to traditional Modbus Plus networks.
  • Regional Data Collection: Suitable for distributed environments, unifying four serial buses with different geographical locations and baud rates into a single MBP link.
  • Independent Installation: Utilizes an independent DIN rail mounting architecture, eliminating reliance on any PLC backplane power supply or physical slots.
  • Physical Interface: Equipped with one standard Modbus Plus DB9 female port and four independent universal serial communication ports.
  • Hardware Jumpers: Serial ports support free switching between RS-232, RS-422, or RS-485 physical electrical signals via internal hardware jumpers.
  • Power Supply Specifications: Employs an external 24V DC industrial standard power supply with a dedicated grounding terminal to resist network interference.
  • Dedicated Software: Parameters are defined using ProSoft's official ProLinx Configuration Builder (PCB) software.
  • Memory Mapping: Features a large-capacity virtual register database for scheduling data streams between the MB+ and the four serial ports.
  • Independent Ports: The four serial ports can be independently configured with baud rate and parity, and can be freely combined and defined as master or slave stations.
  • Offline Download: After configuration, the configuration file must be downloaded to the gateway via a dedicated serial diagnostic port (Configuration Port).
Description
ProSoft 5302-MBP-MCM4 creates a communication link between devices on a Modbus Plus network and equipment using Modbus serial communication. The stand-alone gateway mounts on a DIN rail and provides one Modbus Plus port together with up to four Modbus-enabled serial ports. Both the Modbus Plus and Modbus protocol drivers support master and slave operation, allowing the gateway to communicate with controllers and field devices in different network roles. ProSoft 5302-MBP-MCM4 can therefore provide a flexible interface for systems combining Modbus Plus equipment with Modbus devices.

ProSoft 5302-MBP-MCM4 provides individually configurable application serial ports supporting RS-232, RS-422, and RS-485 communication. Available communication settings include baud rates from 110 to 115K, one or two stop bits, seven or eight data bits, and none, even, or odd parity. Node addresses from 1 to 247 are software selectable, while RTS timing delays can be configured from 0 to 65535 ms. RTU mode uses CRC-16 error checking, and ASCII mode uses LRC error checking, allowing communication parameters to be matched with different Modbus devices.

ProSoft 5302-MBP-MCM4 uses a single DB9 female Modbus Plus port, with the protocol driver configurable as either a master or a slave. A DB-9M RS-232 configuration port is provided without hardware handshaking. Application serial ports support configurable RS-232 handshaking, and screw termination is included for RS-422 and RS-485 connections. LED indicators show power and module status, application status, serial port activity, and serial activity or error status, providing useful visual information during commissioning and troubleshooting.

ProSoft 5302-MBP-MCM4 operates from a nominal 24 VDC power supply with an allowable range of 18 to 36 VDC and a maximum current load of 500 mA at 24 VDC. Power connections use positive, negative, and ground terminals, with a 2.5 mm screwdriver blade specified for the terminals. The gateway operates from -20 to 50°C, can be stored from -40 to 85°C, and supports 5% to 95% relative humidity without condensation. Typical applications include manufacturing, oil and gas, electrical power, and food processing systems requiring integration between Modbus Plus and Modbus equipment.
Alternative Names
53O2-MBP-MCM4 5302MBPMCM4 5301-MBP-MCM 5301-MBP-DH485 5301-MBP-101S 5301-MBP-103M 5302-MBP-DFCM4 5302-MBP-ASCII4
Technical notes
Designed for seamless legacy network expansion, the ProSoft 5302-MBP-MCM4 gateway links Modbus Plus controllers to standard serial devices via a high-capacity internal database. It provides an efficient solution for routing data from 4 discrete serial streams into a single Modbus Plus node, saving significant hardware and recabling costs.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What does ProSoft 5302-MBP-MCM4 connect?
ProSoft 5302-MBP-MCM4 connects devices on a Modbus Plus network with equipment using Modbus serial communication. The gateway provides one Modbus Plus port and up to four Modbus-enabled serial ports.
How many Modbus serial ports does ProSoft 5302-MBP-MCM4 provide?
ProSoft 5302-MBP-MCM4 supports up to four Modbus-enabled serial ports. Each application port can be configured individually, providing flexibility when multiple serial devices have different communication requirements.
Can 5302-MBP-MCM4 operate as both master and slave?
Yes. 5302-MBP-MCM4 supports master and slave implementations for Modbus Plus and Modbus protocols. The single Modbus Plus port can also be individually configured for the required operating role.
Does ProSoft 5302-MBP-MCM4 support RS-232, RS-422, and RS-485?
Yes. ProSoft 5302-MBP-MCM4 application serial ports support RS-232, RS-422, and RS-485. RS-232 handshaking is configurable, while screw termination is included for RS-422 and RS-485 connections.