Features:
- The SS3001 specification lists controllers as 2 SZ controllers for the DeltaV SIS SZ Controller configuration.
- The documented ethernet isolation ports for SS3001 is 2 for twisted copper within its DeltaV SIS SZ Controller system role.
- SS3001's documented redundancy is redundant controller assembly in the DeltaV SIS Redundant SZ Controller Assembly with Vertical Carrier configuration.
The current ordering configuration is SS3001, the DeltaV SIS Redundant SZ Controller Assembly with Vertical Carrier identified for the DeltaV SIS SZ Controller.
SS3001 performs its documented system role within the DeltaV SIS SZ Controller architecture. The application and operating limits remain those assigned to this exact ordering configuration.
Before commissioning, confirm vertical mounting, connect both power paths and isolation ports, validate the safety application after replacement.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson SS3001:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Host the DeltaV SIS Local Safety Network using two SZ controllers on the supplied vertical safety carrier.
- Isolate the Local Safety Network from the area control network through the documented Ethernet isolation ports.
- Provide a redundant controller assembly for scalable CSLS safety architectures using twisted-copper network connections.
- The SS3001 specification lists controllers as 2 SZ controllers for the DeltaV SIS SZ Controller configuration.
- The documented carrier for SS3001 is dual vertical safety carrier within its DeltaV SIS SZ Controller system role.
- SS3001's documented ethernet isolation ports is 2 for twisted copper in the DeltaV SIS Redundant SZ Controller Assembly with Vertical Carrier configuration.
- The SS3001 specification lists power plugs as 2 for the DeltaV SIS SZ Controller configuration.
- The documented redundancy for SS3001 is redundant controller assembly within its DeltaV SIS SZ Controller system role.
- SS3001's documented system is deltaV SIS in the DeltaV SIS Redundant SZ Controller Assembly with Vertical Carrier configuration.
- The SS3001 specification lists network medium as Twisted copper Ethernet through isolation ports for the DeltaV SIS SZ Controller configuration.
- The documented orientation for SS3001 is vertical carrier within its DeltaV SIS SZ Controller system role.
- For SS3001, validate the safety application after replacement for the documented SS3001 DeltaV SIS SZ Controller configuration.