Features:
- VE4003S2B10 provides 16 documented channel capacity for this 16-channel four-wire analog input terminal block.
- 4-wire is the documented field wiring for VE4003S2B10 as this 16-channel four-wire analog input terminal block.
- VE4003S2B10 uses a Simplex redundancy arrangement for this 16-channel four-wire analog input terminal block.
The current ordering configuration is VE4003S2B10, the DeltaV 16-Channel 4-Wire Analog Input Terminal Block for Series 2 Plus identified for the DeltaV M-series Traditional I/O.
VE4003S2B10 performs the documented 16-channel four-wire analog input terminal block function within the DeltaV M-series Traditional I/O architecture. Its operation follows the capabilities and limits assigned to this exact ordering configuration.
Before commissioning, match the Series 2 Plus AI card, verify four-wire loop power, and document every terminal before changeout.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson VE4003S2B10:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Terminate 16 four-wire analog input circuits for the matching M-series Series 2 Plus input card.
- Land separately powered transmitter wiring through the documented simplex terminal-block arrangement.
- Provide the field-side termination required for Series 2 Plus 4-20 mA HART analog input channels.
- Series 2 Plus is the documented card generation for VE4003S2B10 as this 16-channel four-wire analog input terminal block.
- DeltaV M-series is the product series associated with VE4003S2B10 and its 16-channel four-wire analog input terminal block.
- Document every terminal before changeout before placing VE4003S2B10 in service.
- Install VE4003S2B10 only with the carrier, terminal, and field-wiring components documented for this 16-channel four-wire analog input terminal block.
- Analog input termination is the documented signal role for VE4003S2B10 as this 16-channel four-wire analog input terminal block.
- Verify keying, circuit ratings, and power isolation before connecting or removing VE4003S2B10.
- VE4003S2B10 operates within the documented -40 to 70 degrees C temperature range for this 16-channel four-wire analog input terminal block.
- VE4003S2B10 supports 5 to 95%, non-condensing relative humidity for the documented 16-channel four-wire analog input terminal block.
- Operate VE4003S2B10 only within the temperature and humidity limits published for this 16-channel four-wire analog input terminal block.