Features:
- Measures large-shaft displacement without mechanical contact.
- Provides a 4 V/mm sensitivity across the documented static range.
- Uses the exact M18, unarmored, 100 mm sleeve and 8 m open-end configuration.
The sensor/converter pair provides non-contact shaft-displacement measurement for large turbomachinery, including radial vibration, axial position, eccentricity and speed/key observation.
The converter drives a high-frequency electromagnetic field at the probe tip. A nearby ferromagnetic shaft changes the eddy-current loss as the gap varies, and the converter translates that change into a proportional electrical output.
Set the mechanical gap using the matched PR6424/CON041 calibration data and the actual target material. Sensor, converter and extension-cable identities must remain a calibrated system.
Availability is reviewed against the exact PR6424/006-131 CON041 order identity and requested supply condition; manufacturer lifecycle status: Active / Available from OEM.
Verified resources for Emerson EPRO PR6424/006-131 CON041:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- The /006 sensor execution combines the M18 x 1.5 unarmored body with the 100 mm sleeve code. The -131 suffix identifies no adapter plug, 8 m total cable length and an open cable end in the official order matrix.
- The larger 16 mm probe is suited to machines with shafts at least 80 mm in diameter and to installations requiring the documented +/-2 mm static measuring range.
- Operates only as a calibrated probe, cable and CON041 converter system.
- Provides 4 V/mm sensitivity with linearity within ±1.5%.
- Delivers a static measurement range of ±2.0 mm.
- Supports non-contact displacement monitoring on large rotating machinery.
- Uses the documented PR6424 16 mm eddy-current sensor execution.
- Provides an M18 x 1.5 threaded sleeve for mechanical mounting.
- Complete order code specifies an unarmored cable construction.
- Requires an 80 mm minimum shaft diameter for documented geometry.
- Gap changes eddy-current loading, which the converter translates into proportional output.
- Sleeve code 006 specifies a 100 mm case length.