/ 4.9
1001 reviews | Need a Specific Revision?
Emerson PR9268/017-100 is an omnidirectional absolute-vibration transducer for service up to 100°C, supplied with a 10 m non-armored cable and open cable end.
In Stock
Ships by Friday, October 30
Fast Shipping Available
Get a quick price for PR9268/017-100
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for PR9268/017-100

  • Manufacturer:
    Emerson
  • Part Number:
    PR9268/017-100
  • Product Family:
    Epro
  • Product Type:
    PR 9268 Absolute Vibration Transducer
  • Stock:
    1
  • Measurement Principle:
    Electro-dynamic seismic
  • Measurement:
    Omnidirectional
  • Temperature Selection:
    Up to 100°C
  • Cable:
    10 m, non-armored
  • Cable End:
    Open cable end
  • Protection Class:
    IP65 for PR9268/01x family
  • Operating Temperature:
    -20 to +100°C; short time to 120°C
  • Storage and Transport:
    -40 to +100°C without packing; -40 to +70°C packed
  • Relative Humidity:
    0 to 100%, non-condensing in housing and plug
  • Tariff Code:
    9031809090
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Performance Environment Integration

Features:

  • Measures absolute vibration through an electro-dynamic seismic transducer.
  • Selects omnidirectional operation up to 100°C.
  • Includes a 10 m non-armored cable with open cable end.
The current ordering configuration is PR9268/017-100, combining the /01 omnidirectional sensor family with a 10 m non-armored open-ended cable.

It converts housing vibration velocity into a proportional electrical signal for machinery monitoring or protection equipment.

Before installation, verify the mounting direction, stiff support, cable polarity, shielding, measurement range and trip logic for the connected monitor.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Emerson PR9268/017-100: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Measures absolute casing vibration on rotating machinery.
  • Feeds vibration-velocity signals to compatible machinery monitoring channels.
  • Supports protection measurements where an omnidirectional 100°C transducer is specified.
  • The seismic moving coil generates an output proportional to vibration velocity above resonance.
  • Measurement quality depends on a rigid mounting surface and the defined sensing direction.
  • The selected range and alarm limits must be matched to the monitored machine.
  • The /01x sensor family operates from -20 to +100°C, with short exposure up to 120°C.
  • The housing carries IP65 protection when installed according to the guide.
  • The selected non-armored cable must be protected from mechanical damage and aggressive conditions.
  • Mount the transducer on a stiff, vibration-free holder using the documented mounting hardware.
  • Route the 10 m cable without torsion or elongation and preserve the open-end conductor identification.
  • Verify polarity, grounding and EMC-compatible cable routing before activating protection logic.
Description
PR9268/017-100 is an electro-dynamic absolute-vibration transducer that works on the seismic measurement principle. Its order code selects omnidirectional measurement for temperatures up to 100°C.

The 017 selection provides a 10 m non-armored cable, while the 100 termination specifies an open cable end. The moving coil generates a voltage proportional to vibration velocity when operated above resonance.

Use a stiff, vibration-free mounting point and route the cable without torsion, elongation or damage. Verify measuring direction, trip limits, polarity and EMC-compatible shielding before putting the protection channel in service.
Alternative Names
PR9268/017-100 Emerson PR9268/017-100 PR9268 017 100 PR9268-017-100 PR9268017100 Emerson AMS 6500 Machinery Health PR9268/017-100 Emerson PR 9268 Absolute Vibration Transducer Emerson PR 9268 Absolute Vibration Transducer PR9268/017-100
Technical notes
Mount PR9268/017-100 on a rigid surface with correct orientation and polarity, then prove the transducer, 10 m cable, monitor scaling, alarms, and trip chain.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What mounting concern remains important even though PR9268/017-100 is omnidirectional?
The transducer still requires a rigid prepared mounting surface, correct polarity and secure cable routing so structural movement does not distort the measured casing vibration.
How should a monitoring channel be qualified for PR9268/017-100?
Confirm the channel accepts the electro-dynamic transducer signal, wiring polarity, cable termination and the machine protection system's configured measurement scaling.
Why is PR9268/017-100 selected for casing vibration instead of relative shaft displacement?
It is an absolute seismic vibration transducer for machine housings; relative shaft measurements require a different non-contact probe and converter chain.
Which cable-end detail must appear in a PR9268/017-100 sourcing request?
Specify the complete /017-100 code and confirm that the required arrangement is the documented non-armored cable with open conductors, together with quantity and destination.
Can another PR9268 temperature or cable option replace PR9268/017-100 without recalculating the installation?
No automatic interchange is recommended because cable construction, termination and allowable exposure are encoded by the complete option number.
Which installation evidence should accompany a PR9268/017-100 technical inquiry?
Reference Emerson installation guide MHM-97479 and provide the machine location, mounting orientation, channel type and existing cable-route information.