IC660BBA026

/ 4.9
1001 reviews | Need a Specific Revision?
GE IC660BBA026 is a Genius I/O 24/48 V DC current-source analog input block with six isolated channels for 4–20 mA field transmitters.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC660BBA026
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC660BBA026

  • Manufacturer:
    General Electric
  • Part Number:
    IC660BBA026
  • Product Family:
    GE Genius I/O
  • Product Type:
    24/48 V DC Current-Source Analog 6-Input Block
  • Stock:
    1
  • Input Channels:
    6 isolated current inputs
  • Nominal Input Range:
    4–20 mA
  • Extended Input Range:
    0–25 mA
  • Input Resolution:
    1 µA
  • Input Accuracy at 25 °C:
    0.1% of full scale
  • Input Conversion Time:
    16–400 ms, selectable
  • Channel Isolation:
    Each input isolated from other block circuits; BSM circuitry common to input 1
  • Loop Excitation:
    24 V current-loop supply per input
  • Maximum Excitation Current per Channel:
    25 mA
  • Block Operating Voltage:
    18–56 V DC
  • Diagnostics:
    Open wire, high alarm, low alarm, overrange, underrange
  • Configuration:
    Hand-held monitor or compatible programming software
  • Compatible Bus Switching Module:
    IC660BSM021 for redundant bus use
  • Heat Dissipation:
    12 W maximum
  • Dimensions:
    8.89 × 22.44 × 10.00 cm
  • Weight:
    1.8 kg
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Assembly Match Loop Wiring Configuration Application
  • Connects six isolated 4–20 mA current loops to a Genius I/O bus
  • Provides individual transmitter excitation and configurable signal conversion
  • Reports open-wire, alarm, overrange, and underrange conditions

IC660BBA026 is the 24/48 V DC member of GE's six-input current-source analog block pair.

Each channel supplies a field loop, converts current to controller data, and supports configuration of scaling, conversion time, alarms, fault reporting, and redundancy behavior.

Correct replacement requires Phase B system compatibility, the proper terminal and electronics assemblies, 24/48 V DC power, Genius network settings, and the saved block configuration.

Availability, condition, price, and shipping time for IC660BBA026 are confirmed during quotation.

GE IC660BBA026 Genius Analog Input Block Manuals, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Confirm IC660TBA026 terminal and IC660EBA026 electronics assembly identities
  • Check Phase B controller, software, and hand-held-monitor compatibility
  • Do not interchange the block with the differently powered IC660BBA106
  • Verify 24/48 V DC block power, polarity, grounding, and enclosure practice
  • Land each transmitter loop on its documented excitation, input, common, and ground terminals
  • Use IC660BSM021 only where the approved redundant-bus design requires it
  • Restore device number, baud rate, reference address, and report-fault settings
  • Reapply channel scaling, conversion time, alarms, and active-state selections
  • Validate input current and controller engineering values channel by channel
  • Remote acquisition of six isolated 4–20 mA process transmitters
  • Genius I/O analog input on 24/48 V DC powered stations
  • Redundant Genius bus analog measurement using the documented BSM arrangement
Description
IC660BBA026 is a GE Fanuc Genius I/O current-source analog input block powered from a 24/48 V DC source.

It accepts six isolated 4–20 mA input loops, supplies excitation for field transmitters, converts each signal to engineering data, and reports configurable input diagnostics.

Before replacement, confirm Phase B hardware, bus compatibility, terminal and electronics assemblies, device number, baud rate, input scaling, alarms, redundancy settings, and saved configuration.
Alternative Names
IC660BBA026 IC660 BBA 026 GE IC660BBA026 GE Fanuc IC660BBA026 Genius I/O IC660BBA026 24/48 VDC Current-Source Analog Input Block IC660BBA026
Technical notes
IC660BBA026 requires Phase B compatibility, 24/48 V DC block power, correct TBA026/EBA026 assemblies, Genius address and baud settings, channel configuration, and BSM021 selection; confusing BBA106 can damage the installation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What is the practical difference between GE IC660BBA026 and IC660BBA106?
Both are six-input current-source analog blocks, but IC660BBA026 uses 24/48 V DC block power while IC660BBA106 uses 115 V AC/125 V DC; they are not power-compatible substitutes.
Which removable assemblies belong to GE IC660BBA026?
GE documentation identifies IC660TBA026 as the terminal assembly and IC660EBA026 as the electronics assembly; match both labels before combining or replacing parts.
What should be saved before replacing GE IC660BBA026?
Save the Genius device number, baud rate, channel scaling, alarm limits, conversion times, fault reporting, CPU redundancy, BSM control, and the controller configuration.
Can GE IC660BBA026 be used on a redundant Genius bus?
Yes, when the documented IC660BSM021 24/48 V DC Bus Switching Module, wiring, block configuration, and controller redundancy design are present.
How should an open-wire alarm from GE IC660BBA026 be investigated?
Check transmitter power, loop polarity, excitation output, field wiring continuity, terminal seating, loop current, scaling, and the configured diagnostic threshold before replacing the block.
Why does the Phase B identity matter for GE IC660BBA026?
The GE manual lists IC660BBA026 as a Phase B product without a Phase A equivalent; confirm host controller, software, and hand-held-monitor compatibility with the actual hardware revision.
What is the main selection risk for GE IC660BBA026?
The main risk is confusing it with the 115 V IC660BBA106 or mixing incorrect terminal/electronics assemblies, power source, and saved block configuration.