269PLUS-100P-120

GE 269PLUS-100P-120 is a 269 Plus digital motor management relay configured for 100 Ω platinum RTDs and 120 V AC / 125 V DC control power.

In Stock Ships by Wednesday, November 25 Fast Shipping Available
Dispatched within 24 hours of a confirmed order.
Nameplate and packaging photographs supplied before dispatch.
ISO 9001:2015 certified

Industry compliance and certified quality in every part we supply.

View certificate

Get a price for 269PLUS-100P-120

269PLUS-100P-120General Electric 269 Plus Motor Management Relay
Edit or add anything — monitor type, cable length, other part numbers.

Tell us which and we will shape the quote around it.

Attach a nameplate photo and an engineer will confirm the exact part number before quoting.

Answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8. Used only for this quotation.

Your Quote Request Has Been Received

Thank you. Our sales team will review your request and contact you shortly.

Ordering, delivery and after-sales

Your account managerNamed, start to finish

Your enquiry is picked up by a named account manager who checks the configuration before pricing and stays with the order through dispatch and after-sales. You are not passed round a shared inbox.

  • Direct email and WhatsApp for that person
  • Quotation signed by whoever prepared it
  • Same contact if anything needs sorting later

Enquiries are answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8.

Warranty12 months from shipment

Twelve months from date of shipment against functional defects under normal operating conditions. Because Apter Power is an independent supplier, the manufacturer’s own warranty does not apply — ours stands in its place, which on a discontinued part is the only cover there is.

If it arrives faulty or does not fitReturn authorisation same day

A written procedure, not a negotiation.

  • Report the fault within the 12-month warranty period
  • We issue a return authorisation the same working day
  • Return the unit within 14 days of reporting, in antistatic packaging where applicable
  • Replacement, repair or refund at our option, confirmed in writing
  • Return shipping on a confirmed warranty defect is at our cost

If it turns out to be a configuration mismatch rather than a fault, we help you identify the correct part instead of leaving you with the wrong one.

Pre-dispatch inspectionWhat we check — and what we don’t

Checked:

  • Part number and revision read from the unit nameplate, and photographed
  • Outer packaging and seals inspected and photographed
  • Connector threads and mounting stud checked for damage
  • Quantity and accessory contents verified against the packing list

Not checked: no powered functional or calibration test is performed on this item; sensitivity and frequency response are not re-certified by Apter Power; no hazardous-area certification is issued by us. If you need a functional test report before shipment, ask when you request the quote and we will confirm whether it is possible and what it adds to the lead time.

Our quality management is certified to ISO 9001:2015. More usefully, the scope above is published rather than summarised as “tested and approved” — nothing is implied that we did not do.

Shipping, customs and documentsDispatch in 24h · 170+ countries

Dispatch within 24 hours of a confirmed order for items held in stock. DHL, FedEx and UPS express to 170+ countries, typically 3–6 working days door to door; tracking is emailed the day the order leaves us. Shipping method and cost are itemised on every quotation and never added afterwards.

Most delays on an international spare are paperwork rather than freight, so the documents are prepared before the parcel leaves:

  • Commercial invoice and packing list on every shipment
  • Certificate of Origin prepared on request — ask at enquiry stage
  • HS code stated on the quotation, not discovered at clearance
  • We work to your broker’s format if you tell us what it is
PaymentTelegraphic transfer only

We accept payment by telegraphic transfer (T/T) only. Bank details appear on the pro-forma invoice and nowhere else — we never send revised bank details by email after quoting. If you receive a message claiming our account has changed, call +86 15359408275 before paying.

How to orderSend the part number

Send the enquiry above, or email the part number, quantity and destination country. In-stock items show a live quantity; where a part is not held we show "Ask" and confirm availability from our supplier network before quoting, so you are never quoted a lead time we cannot meet.

Discover the experience, people and global sourcing expertise behind Apter Power. About us »

Technical specifications

 set by the part-number suffix dotted  awaiting confirmation against the OEM datasheet

Part identification

Manufacturer
General Electric
Part Number
269PLUS-100P-120
Product Family
GE Multilin
Product Type
269 Plus Motor Management Relay
Stock
1
Weight
2.8 kg
Tariff Code
8536490090
Country of origin
USA
Place of shipment
Xiamen, Fujian, China

More information

  • Motor thermal, current, phase, ground-fault, and temperature protection
  • 100-ohm platinum RTD option with 120 V AC / 125 V DC control power
  • Programmable inputs, output relays, analog signaling, and Modbus RTU

269PLUS-100P-120 combines motor protection, temperature supervision, output control, and serial reporting in the GE Multilin 269 Plus platform.

The option code matters because RTD sensor type and control-power range must match the installed field circuits before any functional test is attempted.

Reliable protection depends on verified motor and CT data, sensor wiring, thermal settings, trip logic, communication parameters, contactor or breaker interfaces, and documented injection testing.

Availability, condition, price, and shipping time for 269PLUS-100P-120 are confirmed during quotation.

General Electric 269PLUS-100P-120 269 Plus Motor Management Relay Manuals, Product Family, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Thermal capacity tracks motor heating and cooling behavior
  • Phase-current, ground-fault, unbalance, and reversal functions supervise electrical faults
  • Trip and alarm assignments require coordination with the motor starter
  • The 100P code identifies 100-ohm platinum RTD compatibility
  • RTD locations should map to windings, bearings, and process points
  • Open, shorted, noisy, or miswired sensors require separate diagnosis
  • Programmable contacts connect protection decisions to the starter or breaker
  • The analog output can export a selected operating quantity
  • RS-485 Modbus RTU supports supervisory-system data exchange
  • Pump-motor protection with undercurrent supervision for loss of suction
  • Fan-motor protection with undercurrent supervision for loss of airflow
  • Conveyor-drive protection with undercurrent supervision for a broken belt

Description

269PLUS-100P-120 is a GE Multilin 269 Plus motor management relay whose order code identifies the 100-ohm platinum RTD version and the 120 V AC / 125 V DC control-power option.

The relay provides motor thermal modeling, phase-current and ground-fault protection, programmable digital inputs, output relays, analog signaling, RTD monitoring, event information, and RS-485 Modbus RTU communications.

Before installation, verify current-transformer ratios, motor full-load current, RTD wiring and sensor type, control voltage, trip and alarm assignments, output contacts, communication settings, thermal model, and the site protection study.

Case studies

Order from our published case studies. Each one names the customer situation, the parts involved and what changed.

Leonia
IndiaSiemens SIMATIC S7-400 PS 407 · 6ES7407-0DA01-0AA0

Siemens PS 407 Verified for an Indian Textile Plant

An Indian textile manufacturer asked Apter Power to verify Siemens SIMATIC S7-400 PS 407 module 6ES7407-0DA01-0AA0 by complete catalogue number, visible condition and packaging evidence before the next supply decision.

24/7Textile plant support
100%Inspected for Original & New product
“ Apter made our first overseas purchase of Siemens S7-1200 spares straightforward, with clear model confirmation and delivery arrangements. — Singh ”
Leonia · India · 9 October 2026
Read the full case study
May
Malaysia3500/22M

Malaysia Customer Collects Bently Nevada 3500/22-01-02-00 After On-Site Inspection

After equipment downtime, a Malaysian customer travelled to Xiamen to inspect and collect a Bently Nevada 3500/22-01-02-00. The unit could be tested and put into use the next day, helping shorten factory downtime and reduce associated losses.

5On-site checks
1 dayReady for testing
“ Apter responded quickly and had the right Bently Nevada module ready for us to inspect and collect. — Shah ”
May · Malaysia · October 2026
Read the full case study
Myrtle
Saudi ArabiaGE Fanuc IC693CPU364

Saudi Buyer Verifies GE IC693CPU364 On-Site

An Saudi project buyer with a China-based office visited three suppliers with an engineer after a previous purchase resulted in poor-quality goods that were not regarded as original. Following an on-site review of GE Fanuc IC693CPU364, IC693CPU372, IC693ALG391 and other stock in Xiamen, the customer selected IC693CPU364, placed an order and planned to test the module first.

3GE models reviewed
Trial OrderTest before wider purchase
“ Seeing the actual GE modules and stock in person gave us confidence to place our first test order. — Hassan ”
Myrtle · Saudi Arabia · October 2026
Read the full case study

Where this item is used

The nine industries we publish solutions for. Each links through to that industry page.

FAQs

Questions we actually get about this item. If yours is not here, put it in the message field above.

About this part

How can the correct replacement for GE 269PLUS-100P-120 be confirmed before purchase?

Compare the complete nameplate code, enclosure and mounting arrangement, rear-terminal numbering, CT connections, RTD configuration, control-power source, output assignments, and communication interface with the installed relay and panel drawings.

How should current transformers be matched to GE 269PLUS-100P-120?

Confirm CT primary and secondary ratings, polarity, phase order, burden, grounding, and the relay ratio settings, then perform approved secondary-injection tests before protecting a motor.

Which RTD checks are required for GE 269PLUS-100P-120?

Verify 100-ohm platinum sensors, lead compensation, terminal allocation, shield grounding, open or short detection, temperature units, alarm levels, trip levels, and the motor winding map.

Can GE 269PLUS-100P-120 settings be copied from another motor?

Only after an engineering review. Motor current, service factor, acceleration time, cooling, thermal limits, CT ratios, start frequency, load behavior, and protection coordination can differ materially.

How should RS-485 wiring be commissioned on GE 269PLUS-100P-120?

Confirm two-wire polarity, shield practice, termination, biasing, baud rate, parity, unique address, Modbus register mapping, and isolation from noisy power conductors.

What should be tested after replacing GE 269PLUS-100P-120?

Test trip and alarm outputs, contact logic, digital inputs, current channels, ground-fault path, RTDs, analog output, communications, thermal memory, and breaker or contactor interlocks.

Why can GE 269PLUS-100P-120 indicate undercurrent on a running motor?

Investigate CT scaling and wiring first, then check pump suction, fan airflow, conveyor belt integrity, load coupling, threshold settings, time delay, and the actual mechanical load.

Can't find the part number you need?

We quote thousands of parts that never appear on this site — current, obsolete and hard to find. Send the number and we will tell you honestly whether we can get it.

Mon–Fri 09:00–18:00 GMT+8 · enquiries answered within 2 working hours

Talk to our team

An account manager works the enquiry through with you — checking the configuration before pricing, rather than sending a price list back.

Mon–Fri 09:00–18:00 GMT+8 · Xiamen, China

ISO 9001:2015 certified

Every part we supply meets industry standards and comes from a certified quality management system.

View certificate

You may also like

UR7HH
The GE Multilin UR7HH Communications Module is part of the Universal Relay (UR) series, which provides advanced protection, control, and monitoring for electrical power systems.
SR489-CASE 489-P1-HI-A20-E
General Electric SR489-CASE 489-P1-HI-A20-E 489 Generator Management Relay is a microprocessor-based protection and control device designed for synchronous and induction generator systems. It integrates protection, fault diagnostics, power metering, and RTU functions in a single drawout package, supporting reliable generator management in industrial power environments.
UR8AH
The GE UR8AH is a CT/VT module for Multilin UR relays, providing 6 CT inputs (3 phase + 3 ground) and 4 VT inputs for power system monitoring and protection.
In stock
MIVII3000E00HI00
The GE Multilin MIVII3000E00HI00 is a compact 1/4 19-inch 4U rack-mounted numerical protection relay engineered for power system automation. It integrates multi-stage voltage monitoring.
In stock
UR6DH
GE Vernova UR6DH is a Multilin Universal Relay 6D digital input module with sixteen contact inputs, selectable wetting thresholds and configurable debounce. It feeds breaker status and interlock signals into UR FlexLogic.
In stock
269PLUS-D/O-100P-125VDC
GE Multilin 269PLUS-D/O-100P-125VDC is a drawout motor management relay configured for a 100-ohm platinum RTD input and 125 VDC control power.
In stock
469-P5-HI-A1
GE Multilin 469-P5-HI-A1 is a motor management relay configured for 5 A phase-CT secondaries, high-range control power and 0–1 mA analog outputs.
In stock
UR6AH
GE Multilin UR 6A digital I/O module with two Form-A outputs, two Form-C outputs and eight digital inputs.
In stock
MVAJ105RA0802A
GE Vernova MVAJ105RA0802A is an MVAJ105 hand and electrical reset trip relay in a size 2 case, specified for 110/125 V with eight make and two break contacts.
In stock
SR760 760-P1-G1-S1-HI-A20-R
GE SR760 760-P1-G1-S1-HI-A20-R is a feeder-management relay with 1 A phase, ground and sensitive-ground inputs, high-range control power and eight 4–20 mA outputs.
In stock

Looking for a part-number suffix that is not listed? We quote thousands of Bently Nevada configurations that never appear on the site — send the part number.

Same kind of part from other manufacturers:

Product browsing history

Request a quote WhatsApp Chat