Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail info@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides documentation, procurement support and system-matching guidance for General Electric IC200UDD240.

IC200UDD240

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC200UDD240 is a 40-point VersaMax Micro PLC with twenty-four 24 VDC inputs, sixteen 24 VDC sink outputs and a 24 VDC power supply.
In Stock
Ships by Tuesday, September 29
Fast Shipping Available
Get a quick price for IC200UDD240
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC200UDD240

  • Manufacturer:
    General Electric
  • Part Number:
    IC200UDD240
  • Product Family:
    GE VersaMax
  • Product Type:
    40-Point VersaMax Micro PLC
  • Stock:
    1
  • Integrated I/O:
    24 inputs / 16 outputs
  • Input Type:
    24 VDC positive or negative logic
  • Output Type:
    24 VDC sink transistor
  • Controller Supply:
    24 VDC nominal
  • Power Input Range:
    19.2-30 VDC
  • Load Current:
    0.5 A per point at 24 VDC
  • High-Speed Counters:
    Up to four Type A or one Type A plus one Type B
  • Maximum Counter Frequency:
    100 kHz
  • Pulse/PWM Frequency:
    Up to 65 kHz
  • Serial Port:
    Built-in RS-232, RJ-45
  • Supported Protocols:
    SNP/SNPX, Modbus RTU, Serial I/O
  • Program Memory:
    24K words
  • Register Memory:
    32K words
  • Auxiliary 24 VDC Output:
    435 mA maximum
  • Estimated shipping dimensions:
    15 x 9 x 7.6 cm (W x H x D)
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Connectivity Pulse Control Memory Setup Applications

Features:

  • Combines twenty-four configurable 24 VDC inputs with sixteen sink transistor outputs.
  • Runs 100 kHz counters and compatible pulse or PWM outputs up to 65 kHz.
  • Adds flash-backed programming, serial communications and removable field terminals.
Twenty-four inputs let General Electric IC200UDD240 collect positive- or negative-logic signals from pushbuttons, limit switches and proximity switches. Sixteen sink outputs consolidate compatible 12/24 VDC loads in the same controller.

Eight dedicated input points can be assigned to fast counting, including 16-bit and 32-bit counter arrangements. Output channels can be allocated to PWM, pulse-train, ramped pulse-train or motion-related service while the remaining points continue normal control.

Installation components include removable screw-down barrier-style terminal strips with protective covers, an RS-232 RJ-45 Port 1, a configurable Run/Stop switch, an optional Port 2 position and a removable Memory Pack connection.

The General Electric IC200UDD240 40-Point VersaMax Micro PLC may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
General Electric IC200UDD240 40-Point VersaMax Micro PLC Manuals,Datasheets,LinkImportant Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Port Roles and Expansion

  • Primary interface: Use the built-in RS-232 RJ-45 port for programming or serial device communications.
  • Protocol roles: Configure SNP/SNPX master or slave, Modbus RTU master or slave, or Serial I/O.
  • Second channel: Fit a supported RS-232 or RS-485 option module when two serial paths are needed.
  • Shared monitoring: With Port 2 installed, both ports can monitor simultaneously although only one programs at a time.

Counter and Motion Assignments

  • Fast inputs: Assign inputs I1-I8 to Type A, Type B or supported 32-bit high-speed counter combinations.
  • Frequency limit: Process counter signals up to 100 kHz when wiring and pulse width meet the input requirements.
  • Output choices: Select PWM, pulse-train or ramped pulse-train operation on compatible transistor channels.
  • Mixed operation: Leave unassigned points in standard I/O service while dedicated channels perform pulse functions.

Program Retention Choices

  • Application capacity: Use 24K words of program memory and 32K words of registers for the controller project.
  • Startup source: Load configuration and application data from RAM or flash at power-up.
  • Short-term backup: The internal capacitor retains RAM and the time-of-day clock for at least 30 minutes at 25 C.
  • Portable storage: Install the removable Memory Pack when field transfer or backup of the application is required.

High-Speed Machine Uses

  • Flow measurement: High-speed counters process pulses from meter-proving or turbine-flow applications.
  • Motion feedback: Type B quadrature counting supports direction-aware position or velocity measurement.
  • Material handling: PWM and ramped pulse-train modes coordinate compatible conveyor or actuator tasks.
  • Machine sequencing: Dense integrated DC I/O handles interlocks, sensors, indicators and controlled loads.
Description
For compact machines that need dense transistor I/O, the General Electric IC200UDD240 combines twenty-four configurable 24 VDC inputs with sixteen sink-type outputs. Each input may use positive- or negative-logic wiring, and eight points can be assigned to high-speed counting.

Motion-related signals can remain inside the controller rather than requiring a separate pulse module. The General Electric IC200UDD240 supports Type A and Type B counters up to 100 kHz, while compatible outputs provide PWM, pulse-train and ramped pulse-train operation up to 65 kHz.

Output circuits on the General Electric IC200UDD240 are isolated from logic, tolerate high inrush loads, and resist negative voltage pulses. A shared VC and COM feed the sixteen 0.5 A points used for compatible lamps, inductive devices and other 12/24 VDC loads.

Controller resources in the General Electric IC200UDD240 include 24K words of program memory, 32K words of registers, flash storage and an optional removable Memory Pack. The built-in RS-232 port handles SNP/SNPX, Modbus RTU and Serial I/O roles, with a second port available through an option module.
Alternative Names
GE Fanuc IC200UDD240 IC 200 UDD 240 General Electric IC200UDD240 IC200-UDD240 IC2OOUDD240 VersaMax Micro IC200UDD240 GE IC200UDD240 IC200 UDD240
Technical notes
General Electric IC200UDD240 combines 40 integrated points with 100 kHz high-speed counting and 65 kHz pulse or PWM output capability for compact machine control.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why does a 24 VDC sensor stay OFF on General Electric IC200UDD240 even though voltage is present?
Confirm that the sensor common and point wiring match the positive- or negative-logic configuration selected for General Electric IC200UDD240, then verify that the signal reaches the 18 VDC minimum ON threshold.
A sink output on General Electric IC200UDD240 will not energize a lamp; what should be checked first?
For General Electric IC200UDD240, check the external 12/24 VDC load source, VC and COM connections, load polarity and current demand before testing the assigned output in logic.
Which checks help prevent missed pulses when General Electric IC200UDD240 is used with an encoder?
Route the encoder to the dedicated high-speed inputs, select the correct Type A or Type B mode, and match edge and quadrature settings in the General Electric IC200UDD240 hardware configuration.
Can standard I/O and pulse-train control operate together on General Electric IC200UDD240?
Yes. General Electric IC200UDD240 can keep unused points as regular I/O while configured counter and compatible output channels handle PWM, pulse-train or ramped pulse-train functions.
What must be compared before General Electric IC200UDD240 replaces another 40-point VersaMax Micro PLC?
A safe comparison for General Electric IC200UDD240 covers sink versus source or relay outputs, 24 VDC supply range, terminal assignments, high-speed channel allocation, program compatibility and installed port options.
How should communication troubleshooting start when software cannot reach General Electric IC200UDD240?
Begin with the cable pinout and Port 1 mode on General Electric IC200UDD240, then align baud rate, parity, protocol and master/slave role; an RS-485 channel requires the matching Port 2 option.
What protects the application if General Electric IC200UDD240 loses controller power?
General Electric IC200UDD240 can reload configuration and logic from flash, while its capacitor retains RAM and the time-of-day clock for at least 30 minutes at 25 C; the optional battery extends retention.

Product Browsing History