GE DS200TCQBG1BCB
GE DS200TCQBG1BCB
GE DS200TCQBG1BCB
GE DS200TCQBG1BCB
GE DS200TCQBG1BCB
GE DS200TCQBG1BCB
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>

DS200TCQBG1BCB

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric DS200TCQBG1BCB is an RST Extended Analog I/O Board for GE Mark V Speedtronic turbine-control systems.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for DS200TCQBG1BCB
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for DS200TCQBG1BCB

  • Manufacturer:
    General Electric
  • Part Number:
    DS200TCQBG1BCB
  • Product Family:
    GE Mark V/VI Driver Board
  • Product Type:
    RST Extended Analog I/O Board
  • Stock:
    1
  • Series Group:
    Group 1
  • PCB Coating:
    Normal coating
  • Assembly:
    Normal assembly
  • Diagnostic Indicator:
    1 OK LED
  • Primary Connector:
    1 × 50-pin connector
  • Ribbon Interfaces:
    34-pin ribbon-cable connectors
  • Configuration:
    15 hardware jumpers
  • Logic Hardware:
    Programmable logic device
  • Program Storage:
    EPROM modules
  • Dimensions:
    27.8 × 21.2 × 3.5 cm
  • Weight:
    0.66 kg
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Interfaces Configuration Replacement Application
  • TCQB RST extended analog I/O function
  • One 50-pin connector plus 34-pin ribbon-cable interfaces
  • Programmable logic, EPROM storage, one OK LED, and 15 hardware jumpers

DS200TCQBG1BCB is an General Electric RST Extended Analog I/O Board designed for GE Mark V Speedtronic turbine-control systems.

It expands and conditions analog signal paths used by the R, S, and T control cores while interfacing with adjacent Mark V boards through ribbon-cable connections.

Before replacement, verify the full label, receiving position, connector keying, configuration hardware, paired assemblies, and every affected control or feedback path.

Availability, condition, price, and shipping time for DS200TCQBG1BCB are confirmed during quotation.

General Electric DS200TCQBG1BCB RST Extended Analog I/O Board Manuals, Product Family, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • 50-pin connector supports board-level signal exchange
  • 34-pin ribbon-cable interfaces link adjacent control hardware
  • Connector orientation and cable routing must match the installed core
  • Fifteen jumpers provide hardware configuration points
  • EPROM and programmable logic identity must remain matched
  • The side-view OK LED supports basic board-status review
  • Use the complete DS200TCQBG1BCB order string
  • Record every jumper and cable before removal
  • Test all affected analog paths before process release
  • Analog I/O expansion in Mark V gas-turbine controls
  • Analog signal handling in Mark V steam-turbine controls
  • Analog monitoring and control paths in compatible Mark V wind-turbine drive assemblies
Description
DS200TCQBG1BCB contains a programmable logic device, removable EPROM modules, one side-visible OK LED, a 50-pin connector, 34-pin ribbon-cable interfaces, and fifteen configuration jumpers.

As the TCQB board in a Mark V RST arrangement, it extends analog signal processing across the R, S, and T control cores and exchanges conditioned data with the associated control boards.

The installed jumper pattern, EPROM identity, ribbon-cable orientation, and connector assignments must be recorded from the original assembly because these details determine how DS200TCQBG1BCB operates in its specific core position.
Alternative Names
DS200TCQBG1BCB GE DS200TCQBG1BCB General Electric DS200TCQBG1BCB GE Mark V DS200TCQBG1BCB DS200 TCQB G1 BCB DS200-TCQB-G1-BCB
Technical notes
DS200TCQBG1BCB requires the original 15-jumper map, EPROM identity, 50-pin and 34-pin cable orientation, core position, and affected analog paths to match; an incorrect configuration can corrupt RST analog processing.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should General Electric DS200TCQBG1BCB be identified before ordering?
Match the complete DS200TCQBG1BCB label, rst extended analog i/o board function, receiving system, connector population, configuration hardware, and installed position; a shortened family number is not sufficient.
Can General Electric DS200TCQBG1BCB be replaced by a visually similar board?
Only after approved documentation confirms circuit function, suffix compatibility, connector keying, programmed content, paired hardware, and receiving-system requirements.
What should be recorded before removing General Electric DS200TCQBG1BCB?
Photograph both sides and the installed position, label every cable and conductor, record all jumpers or adjustments, and preserve mounting and keying details.
Which handling controls apply to General Electric DS200TCQBG1BCB?
Isolate all energy sources, verify a safe state, use grounded ESD protection, handle the board by its edges, and protect connectors and programmed devices.
How should a suspected General Electric DS200TCQBG1BCB fault be diagnosed?
Compare system diagnostics, supply rails, upstream commands, connector continuity, downstream response, external wiring, and paired hardware before condemning the board.
What must be checked after installing General Electric DS200TCQBG1BCB?
Confirm seating, cable orientation, configuration, grounding, power quality, diagnostics, and every affected signal, relay, feedback, control, or protection path.
Why is the complete suffix important for General Electric DS200TCQBG1BCB?
Suffix characters can identify a different hardware execution or populated board arrangement, so substitution requires the full order string and approved compatibility evidence.