Features:
- Uses a 24 VDC control source for eight inputs and six Form A relay outputs.
- Accepts positive- or negative-logic sensors and built-in counting to 10 kHz.
- Preserves application data in flash and supports four expansion units.
A 19.2-30 VDC operating window lets General Electric IC200UDR002 share a regulated machine-control supply. The internal power section also provides 24 VDC for input circuitry and eligible devices within its 200 mA allowance.
The eight inputs can be filtered for normal signals or assigned to high-speed counter functions. Six isolated relay contacts then switch separately powered AC or DC circuits without tying the load voltage to the controller supply.
Two covered, removable barrier-style terminal assemblies carry the field conductors. An RS-232 RJ-45 port, two analog potentiometers and a configurable Run/Stop switch complete the front-access hardware.
The General Electric IC200UDR002 14-Point 24 VDC VersaMax Micro PLC may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
General Electric IC200UDR002 14-Point 24 VDC VersaMax Micro PLC Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
24 VDC Source Behaviour
- Operating range: Hold the controller input between 19.2 and 30 VDC during steady operation.
- Starting demand: Provide the transient capacity required for the one-amp maximum inrush at 30 VDC.
- Diagnostic delay: With power-up diagnostics disabled, logic solution begins after the input has maintained 24 VDC for 100 ms.
- Hold-up period: The power section maintains operation for 10 ms at 19.2 VDC.
External Load Circuit Rules
- Separate energy: Feed field devices from their own AC or DC source instead of the controller input supply.
- Contact range: Apply loads within the documented 5-30 VDC or 5-250 VAC switching range.
- Current limit: Keep pilot-duty and resistive circuits within 2 A at 24 VDC or 240 VAC.
- Inrush check: Account for the five-amp per-half-cycle contact limit when selecting lamps or coils.
Fast Input Allocation
- Counter options: Choose up to four Type A counters or one Type A together with one Type B.
- Signal ceiling: Limit rapid pulse inputs to 10 kHz with the required duty cycle.
- Edge handling: Set Type A channels for up/down direction and positive or negative edge detection as needed.
- Output restriction: Use relay counter outputs only where applicable; PWM and pulse-train modes are unavailable.
DC-Controlled Machine Tasks
- Cabinet integration: The 24 VDC controller supply fits panels already using a regulated control bus.
- Device actuation: Form A contacts operate compatible starters, valves and indicators with independent field power.
- Event counting: High-speed inputs capture production counts or velocity-related pulses.
- Distributed expansion: Up to four compatible expansion units add I/O around the compact CPU.