IC200UDR120

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC200UDR120 is a 20-point VersaMax Micro PLC with twelve 24 VDC inputs, eight relay outputs and a 120/240 VAC supply.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC200UDR120
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC200UDR120

  • Manufacturer:
    General Electric
  • Part Number:
    IC200UDR120
  • Product Family:
    GE VersaMax
  • Product Type:
    VersaMax Micro 20 PLC
  • Stock:
    1
  • Logic / Data Memory:
    24K words / 32K words
  • Expansion Capacity:
    Up to 4 modules
  • Real-Time Clock:
    Included
  • Second Port Options:
    RS232, RS485, USB or Ethernet
  • Total I/O Points:
    20
  • Inputs:
    12 x 24 VDC
  • Outputs:
    8 relay
  • Power Supply:
    120/240 VAC
  • High-Speed Counters:
    Up to 4 at 100 kHz
  • Pulse / PWM Outputs:
    Up to 4 at 65 kHz
  • Programming Software:
    PAC Machine Edition
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals AC Supply Relay Loads Automation Applications

Features:

  • Runs the CPU from a selectable 120/240 VAC source.
  • Receives twelve 24 VDC input signals for machine-state monitoring.
  • Provides eight dry-contact commands for suitably rated external circuits.
General Electric IC200UDR120 fits installations where AC control power is readily available but sensors use conventional 24 VDC signaling.

Because the CPU supply, input circuits and relay loads can involve different voltage domains, careful segregation and protective grounding are central to a reliable panel layout.

High-speed functions, motion instructions, adaptable communications and four expansion positions give this compact AC-powered PLC room for more advanced control.

The General Electric IC200UDR120 VersaMax Micro 20 PLC may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
General Electric IC200UDR120 VersaMax Micro 20 PLC Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Mains-Powered Controller Design

  • Supply Selection: The CPU accepts a 120 or 240 VAC source within the supported operating range.
  • Circuit Separation: Mains conductors should remain segregated from input, serial and other low-voltage wiring.
  • Protection: Branch protection and protective earth must follow the panel design and applicable practice.
  • Field Sources: The AC input does not eliminate the need for suitable sensor and load power supplies.

Output Circuit Behavior

  • Contact Function: Eight isolated relays provide voltage-independent switching within their ratings.
  • Load Inrush: Coils, lamps and capacitive devices can demand more current at turn-on than in steady operation.
  • Suppression: External suppression can reduce transients and extend contact service in inductive circuits.
  • Troubleshooting: Measure both sides of a contact and verify the load supply before assigning a CPU fault.

Advanced Control Capability

  • Program Capacity: The memory arrangement supports more substantial sequencing and data handling than basic micro controllers.
  • Positioning: Home, jog, ramp and blended-motion commands can coordinate compatible mechanisms.
  • Fast Channels: Dedicated counter and waveform resources handle time-critical signals outside the normal scan.
  • Program Transfer: Portable FLASH can simplify restoration or replication of an approved application.

AC-Powered Machine Uses

  • Standalone Equipment: Direct AC supply suits self-contained panels with local branch protection.
  • Commercial Machinery: Relay outputs can interface diverse control loads while DC inputs receive sensor states.
  • Retrofit Panels: The voltage arrangement may align with older cabinets that already distribute AC control power.
  • Remote Assets: Selectable ports allow service access or connection to a compatible supervisory network.
Description
Powered directly from an AC supply, the General Electric IC200UDR120 VersaMax Micro 20 PLC combines twelve 24 VDC inputs and eight relay outputs in a twenty-point controller.

The 120/240 VAC supply format can reduce the need for a separate DC power unit for the CPU, while field sensors and relay load circuits still require their specified external sources and references.

Processing resources include 24K words of logic memory, 32K words of data memory and an approximate 1.1 ms/K scan rate. A real-time clock, battery and supercapacitor support timed control and retained values.

Four counter channels can handle supported inputs up to 100 kHz, and four pulse/PWM channels can operate up to 65 kHz. Motion commands cover homing, jogging, ramps and blended moves when the application is wired and configured accordingly.

RS232 is provided for direct access, with RS232, RS485, USB or Ethernet available as a second-port choice. The controller also accepts up to four VersaMax Micro expansion modules.
Alternative Names
IC 200 UDR 120 IC200-UDR120 IC200UDR12O IC2O0UDR120 AC-Powered VersaMax Micro 20 PLC 20-Point AC Supply Micro Controller GE Micro 20 UDR120 GE Fanuc IC200UDR120
Technical notes
General Electric IC200UDR120 brings AC line power into the controller; keep mains wiring segregated from 24 VDC input and communication circuits.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What distinguishes General Electric IC200UDR120 from the DC-supply Micro 20 version?
General Electric IC200UDR120 powers its CPU from 120/240 VAC while retaining twelve 24 VDC inputs and eight relay outputs.
Does General Electric IC200UDR120 supply power to all connected sensors?
No; General Electric IC200UDR120 uses AC for controller power, but 24 VDC sensors and switched loads still need properly designed field sources.
What safety checks matter before energizing General Electric IC200UDR120?
Confirm the selected AC voltage, protective earth, branch protection, terminal covers and separation of mains from low-voltage wiring on General Electric IC200UDR120.
Can General Electric IC200UDR120 communicate over Ethernet?
General Electric IC200UDR120 can accept an Ethernet option in its second communication position while retaining the standard RS232 interface.
How are relay loads diagnosed on General Electric IC200UDR120?
For General Electric IC200UDR120, compare logic status with contact voltage, field power, common continuity and the connected device current.
Can General Electric IC200UDR120 support a future I/O increase?
General Electric IC200UDR120 accepts up to four supported expansion modules after station power and addressing have been validated.