Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides MVP50 sourcing assistance, record checks, and compatibility guidance.

MVP50

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric MVP50 is the Nexus OnCore Valve Position Control Module for Nexus OnCore. It performs valve-position control with redundant I/O channels and an on-board PID servo loop.
In Stock
Ships by Thursday, October 29
Get a quick price for MVP50
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for MVP50

  • Manufacturer:
    General Electric
  • Part Number:
    MVP50
  • Product Family:
    Nexus OnCore
  • Product Type:
    Nexus OnCore Valve Position Control Module
  • Stock:
    1
  • Control Function:
    Valve position control
  • I/O Architecture:
    Redundant input and output channels
  • Servo Function:
    On-board PID control loop
  • Supply:
    24 VDC
  • Maximum Power:
    11.0 W
  • Variant Scope:
    Standard MVP50 configuration
  • Ambient Range:
    -20 to +50 degrees C on the certified nameplate
  • Hazardous Marking:
    Class I Division 2 and Zone 2
  • Installation:
    Panel-mounted in a suitable enclosure
  • Tariff Code:
    Please confirm the destination before shipping.
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Valve Performance Environmental Ratings Control Configuration

Features:

  • Regulates valve position through an onboard PID control loop.
  • Uses redundant input and output channels for reliable actuator control.
  • Supports configured actuator feedback within the Nexus OnCore architecture.
MVP50 combines control function of Valve position control, i/o architecture of Redundant input and output channels, and servo function of On-board PID control loop in the Nexus OnCore platform.

It performs valve-position control with redundant I/O channels and an on-board PID servo loop. This role connects the Nexus OnCore Valve Position Control Module to the surrounding Nexus OnCore architecture.

Before commissioning, verify the standard versus high-speed MVP50 variant; match actuator feedback and project configuration; and maintain certified installation and grounding conditions.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for General Electric MVP50:Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Controls industrial valve position through the integrated PID servo loop on the module.
  • Uses redundant I/O channels within the Nexus OnCore valve-control architecture.
  • Supports panel-mounted turbine and process-control applications that require closed-loop actuator control.
  • Operates from the regulated 24 VDC supply provided by the Nexus OnCore system.
  • Consumes up to 11.0 W under the specified valve-control module configuration.
  • Provides the standard valve-position control variant intended for supported actuator installations.
  • Carries a certified -20 to +50 degrees C ambient range on the valve-control module nameplate.
  • Uses Class I Division 2 and Zone 2 markings to identify the approved hazardous-location service.
  • Requires panel mounting inside a suitable enclosure that preserves the applicable certification conditions.
  • Verify whether the installed application requires the standard or high-speed controller variant.
  • Match actuator-feedback characteristics and project settings before commissioning the replacement module.
  • Maintain the certified installation and grounding conditions throughout mounting and service work.
Description
General Electric MVP50 is a Nexus OnCore valve-position control module with redundant input and output channels. It uses 24 VDC power, has an 11.0 W maximum rating, and contains an on-board PID servo loop for the standard MVP50 function.

The module closes the valve-control loop by processing actuator feedback and issuing the corresponding positioning output. Redundant channel paths support dependable motion control in turbine and industrial actuator applications.

Commissioning requires the correct actuator interface, feedback polarity, travel limits, output wiring, and tuned control parameters. Verify that the project calls for the standard MVP50 configuration before replacing another valve-control variant.
Alternative Names
MVP50 MVP50-CBACN MVP50-CBAUS MVP50-CBBCN MVP50-CBBUS MVP50-BBACN
Technical notes
Before servicing MVP50, maintain certified installation and grounding conditions; verify the standard versus high-speed MVP50 variant before commissioning.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which servo architecture is built into MVP50?
MVP50 combines redundant input and output channels with an on-board PID servo loop for valve-position control.
What actuator data must be compatible with an MVP50 installation?
Verify actuator type, feedback signal, command range, channel wiring, standard or high-speed variant, project configuration, and regional suffix.
How does MVP50 regulate a final control element?
It compares the commanded and measured position and drives the compatible actuator through the configured closed-loop control arrangement.
Which variant details must appear on an MVP50 request?
State the full suffix, standard or high-speed scope, actuator and feedback details, condition, quantity, destination, and delivery date.
Why should MVP51 not be treated as an MVP50 equivalent?
MVP51 is associated with triple-redundant LVDT feedback, so its sensing architecture and project configuration are not the same.
What valve-engineering documents should support an MVP50 quotation?
Provide the OnCore certificate, actuator datasheet, servo schematic, feedback calibration, channel assignment, and loop-tuning record.