51304903-200

/ 4.9
1001 reviews | Need a Specific Revision?
Honeywell 51304903-200 is the CE-compliant Winchester Drive Interface I/O board listed for WDA-type History Modules.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 51304903-200
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 51304903-200

  • Manufacturer:
    Honeywell
  • Part Number:
    51304903-200
  • Product Family:
    Honeywell TPS Series
  • Product Type:
    Winchester Drive Interface I/O Board
  • Stock:
    1
  • Board Type:
    WDI
  • Board Description:
    Winchester Drive Interface I/O Circuit Board
  • Compliance Build:
    CE compliant
  • Assembly Context:
    WDA-type History Module
  • Service Level:
    Replaceable parts-list item
  • Weight:
    0.14 kg
  • Estimated shipping dimensions:
    2x13x23.7cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals WDA Context Board Identity Service Boundary Applications

Features:

  • WDI service identity: Honeywell lists the part as the Winchester Drive Interface I/O circuit board.
  • CE build: the -200 version is the CE-compliant WDI board in the WDA-type History Module parts list.
  • Assembly boundary: its documented scope is the Winchester Disk Assembly history-module configuration.
The WDI board belongs to the disk-interface portion of a WDA-type History Module rather than the LCN or smart-peripheral-controller board positions.

Honeywell lists a separate -100 WDI board without the CE designation, so the complete -200 number is part of the configuration identity.

A useful service request names the WDA-type History Module, WDI position and exact board suffix together before any storage-interface work begins.

Apter Power supports Honeywell 51304903-200 Winchester Drive Interface I/O Board quotations, documentation and History Module configuration review.
Honeywell 51304903-200 Winchester Drive Interface I/O Board Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Module family: the parts-list scope is the Winchester Disk Assembly type History Module.
  • Board position: WDI identifies the Winchester Drive Interface I/O circuit-board function.
  • Service level: the board is listed as a replaceable item inside the WDA assembly.
  • Scope limit: the documented identity does not extend automatically to other History Module hardware types.
  • Exact suffix: -200 identifies the CE-compliant WDI build.
  • Related entry: -100 is separately listed as the non-CE WDI board.
  • Function name: retain Winchester Drive Interface in RFQ and receiving records.
  • Position evidence: compare the installed WDI location and complete label before exchange.
  • Drive-interface work: keep WDI diagnosis separate from LCN, controller and power-supply board work.
  • Cable record: identify the original drive-interface connections before removing the board.
  • Module record: link the board asset entry to the WDA-type History Module in which it operates.
  • Functional proof: use the History Module procedure to demonstrate storage-path recovery after exchange.
  • WDA History Module: restores the WDI I/O board position in the Winchester Disk Assembly configuration.
  • Drive-interface service: supports repair work already isolated to the WDI path.
  • CE configuration: preserves the -200 compliance build listed for the module assembly.
  • Legacy storage support: maintains the original interface architecture of the documented Honeywell History Module.
Description
In a WDA-type History Module, 51304903-200 serves as the CE-compliant Winchester Drive Interface I/O circuit board. The exact -200 identity distinguishes it from the separately listed -100 non-CE board in Honeywell’s replaceable-parts tables.

Service planning for 51304903-200 begins at the History Module assembly level, where the WDI board belongs to the drive-interface path rather than the controller or LCN circuitry. That location helps maintenance teams request the correct board when a disk-interface repair has already been isolated.

Because 51304903-200 is documented as a service-level part within the Winchester Disk Assembly configuration, its value lies in restoring the original module build—not in acting as a universal storage adapter. The installed WDA variant and board position should remain the governing fit references.
Alternative Names
Honeywell 51304903-200 51304903200 513 04903-200 51304903 200 513-04903-200 51304903/200 WDI 51304903-200 Winchester Drive Interface 51304903-200
Technical notes
51304903-200 is the CE-compliant WDI I/O board for Honeywell's WDA-type History Module. The parts list also names 51304903-100 as a separate non-CE WDI build, so the common base number is not enough for selection. Keep the History Module type, WDI position and complete -200 suffix together on the service request.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Is 51304903-200 appropriate when a maintenance order identifies the WDI position in a WDA-type History Module?
Yes, that is the documented service context. If the installed position is labeled SPC-2, LCN or controller circuitry instead, this WDI board is not the supported selection for that position.
Should a drive-interface symptom automatically lead a technician to replace 51304903-200?
No. The board belongs to the WDI path, but the parts list does not prove that every storage-path symptom originates on this board. Isolate the WDI position before purchasing a replacement.
What should receiving staff verify on a shipment labeled 51304903-200?
The label should retain the complete -200 number and the WDI or Winchester Drive Interface description. A -100 entry is a separately listed build and should not be booked as the same configuration.
Can 51304903-200 be treated as a general-purpose storage interface?
No. Its documented scope is the WDI I/O position in a WDA-type History Module, so the host assembly and service position remain part of the purchase decision.
When should a buyer place 51304903-200 on hold for engineering review?
Place the order on hold when the installed module is not a WDA type or the required position is not WDI. The available Honeywell parts listing does not establish use outside that boundary.