ICS Triplex T9881 is a simplex termination assembly designed for the AADvance safety controller, providing secure field wiring connections for up to 8 analogue output channels with 1.5 kV isolation.
Get a quick price for T9881
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for T9881

  • Manufacturer:
    ICS Triplex
  • Part Number:
    T9881
  • Product Family:
    AADvance Controller
  • Product Type:
    Analogue Output Termination Assembly
  • Channels:
    8
  • Compatible Modules:
    T9481 (3-ch AO), T9482 (8-ch AO)
  • Field Wiring:
    Max 1.31 mm² (16 AWG)
  • Strip Length:
    6 mm (1/4 in)
  • Channel Isolation:
    ±1.5 kVdc withstand for 1 minute
  • Mounting:
    Clips onto T9300 I/O Base Unit
  • Operating Temperature:
    -25°C to +70°C
  • Storage Temperature:
    -40°C to +70°C
  • Humidity:
    10–95% RH, non-condensing
  • Hazardous Location:
    Class I, Division 2, Groups A, B, C, D
  • Weight:
    0.1 kg
  • Estimated shipping dimensions:
    13x4x4.5cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Applications Operating Environment Certifications & Standards

Features:

  • Hardened Field Wiring Interface
  • High-Isolation Channel Protection
  • Polarized Keying to Prevent Mismating
The ICS Triplex T9881 accepts up to 16 AWG field wiring with screw terminals, ensuring secure, long-term connections in high-vibration industrial environments. The 6 mm strip length simplifies installation and reduces wiring errors.

With ±1.5 kVdc withstand voltage per channel, the ICS Triplex T9881 isolates the safety controller from field-side faults, preventing electrical damage and improving system uptime. This is critical for maintaining safety loop integrity.

The ICS Triplex T9881 uses coding pins and socket alignment to ensure only compatible analogue output modules (T9481/T9482) can be installed. This eliminates field installation errors and speeds up module replacement.

The T9881 ICS Triplex Analogue Output Termination Assembly may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
ICS Triplex T9881 Analogue Output Termination Assembly Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ICS Triplex T9881 Analogue Output Termination Assembly

General

  • Manufacturer ICS Triplex
  • Model T9881
  • Condition New Original ready stock
  • Product Family T9833,T9851,T9852
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Emergency Shutdown Systems (ESD) – The ICS Triplex T9881 connects final control elements like shutdown valves in high-integrity safety loops.
  • Fire & Gas Detection Systems – It drives analogue output signals for alarm annunciators or suppression system actuators.
  • Critical Process Control – Used in refineries and chemical plants to transmit 4–20 mA setpoints to I/P converters and positioners.
  • Burner Management Systems (BMS) – The ICS Triplex T9881 supports precise analogue control of fuel valves and dampers in boiler safety applications.
  • Wide Temperature Range – The ICS Triplex T9881 operates from -25°C to +70°C, suitable for outdoor cabinets and unheated control rooms.
  • Humidity Tolerance – Handles 10–95% relative humidity, non-condensing, for use in tropical or wash-down areas (inside IP54 enclosure).
  • Vibration Resistance – Designed for industrial environments with high vibration (tested per IEC 61131-2).
  • Hazardous Locations – Certified for Class I, Division 2, Groups A, B, C, D, allowing installation in potentially explosive atmospheres without additional protection.
  • Functional Safety – IEC 61508 SIL 2 / SIL 3 capable (when configured with appropriate I/O modules).
  • Hazardous Area – ATEX and IECEx certified for use in Zone 2 / Class I Div 2 environments.
  • EMC Compliance – Meets EN 61326-1 Class A and EN 61131-2 for industrial electromagnetic environments.
  • UL Listing – UL 508 recognized for industrial control equipment, ensuring North American acceptance.
Description
The ICS Triplex T9881 termination assembly serves as the physical interface between the AADvance I/O module and field actuators. Engineered specifically for T9481/T9482 analogue output modules, this simplex TA simplifies installation by integrating all field wiring connections into a single, compact unit. Its robust design supports reliable 4–20 mA current loops for precise process control.

The ICS Triplex T9881 features 8 individual field wiring terminals, accepting conductors up to 1.31 mm² (16 AWG) with a 6 mm strip length. Each channel is isolated to withstand ±1.5 kVdc for one minute, protecting the safety controller from field-side faults. The module locking mechanism and polarization keying prevent incorrect mating, reducing installation errors.

Built for industrial environments, the ICS Triplex T9881 operates reliably across a wide temperature range and is certified for use in hazardous locations (Class I, Div 2). As part of the Rockwell Automation AADvance platform, this termination assembly supports safety integrity levels up to SIL 3 when paired with the appropriate output configuration, making it a trusted choice for critical process safety applications.
Alternative Names
T988I T9802 T9803 T9851 T9831 T9833 T9851 T9852
Technical notes
ICS Triplex T9881 is a simplex analogue output termination assembly with 8 channels, supporting T9481 (3-channel) and T9482 (8-channel) modules. It provides ±1.5 kVdc channel-to-chassis isolation and requires 16 AWG field wiring with a stripping length of 6 mm.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What I/O modules are compatible with the ICS Triplex T9881?
The ICS Triplex T9881 is designed exclusively for T9481 (3-channel) and T9482 (8-channel) analogue output modules within the AADvance platform. It cannot be used with digital or input modules.
What is the channel isolation rating of the ICS Triplex T9881?
The ICS Triplex T9881 provides ±1.5 kVdc withstand voltage between each channel and chassis for one minute, ensuring robust fault containment and protecting the controller from field transients.
Can the ICS Triplex T9881 be used with third-party controllers?
No, the ICS Triplex T9881 is mechanically and electrically matched only to the AADvance I/O platform. It requires a T9300 I/O base unit and Rockwell Automation’s AADvance safety system.
What environmental limits apply to the ICS Triplex T9881?
The ICS Triplex T9881 operates from -25°C to +70°C with 10–95% non-condensing humidity. It is suitable for indoor industrial environments and Class I Division 2 hazardous locations.
What safety certifications does the ICS Triplex T9881 hold?
The ICS Triplex T9881 is certified for use in safety systems up to SIL 3 (IEC 61508) when configured correctly. It also carries ATEX, IECEx, and UL listings for hazardous areas (Class I, Div 2).