Features:
- Precision 50mA Time-Lag Protection
- Genuine OEM Component for AADvance Safety Systems
- Bulk Kit for Maintenance Efficiency
The ICS Triplex T9901 is engineered with a 50mA time-lag characteristic to protect sensitive analog and digital input channels. Unlike fast-acting fuses, the time-lag design allows brief inrush currents from field sensors (e.g., pressure transmitters or proximity switches) to pass without interruption, while still clearing persistent overcurrent faults to prevent damage to the AADvance I/O module.
As a Rockwell Automation original spare part, the ICS Triplex T9901 guarantees form-fit-function compatibility with AADvance termination assemblies T9801/2/3 and T9831/2/3. Using certified replacement fuses ensures that the Safety Instrumented Function (SIF) maintains its SIL 2/SIL 3 rating and that internal channel diagnostics (e.g., open-circuit and short-circuit detection) operate within their specified safety accuracy limits.
Each ICS Triplex T9901 kit contains 20 fuses, allowing plant maintenance teams to stock a single part number for multiple I/O termination types. This reduces inventory complexity and ensures immediate availability during corrective maintenance, minimizing system downtime. The fuses are field-replaceable without soldering, using standard fuse holders on the termination assembly.
The T9901 ICS Triplex Replacement Input Fuse Kit may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
ICS Triplex T9901 Replacement Input Fuse Kit Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
ICS Triplex T9901 Replacement Input Fuse Kit
General
- Manufacturer ICS Triplex
- Model T9901
- Condition New Original ready stock
- Product Family T9100,T9110,T9191
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- IEC 61508 SIL 3 Capable – When installed in an AADvance controller configured for SIL 3, the ICS Triplex T9901 does not degrade the safety integrity. Its failure modes (open-circuit, short-circuit) are fully covered by the module’s internal diagnostics, as required by IEC 61508-2.
- IEC 61511 for Process Safety – The fuse complies with the “proven-in-use” requirements of IEC 61511 for process industry safety instrumented functions. Field replacement procedures are documented in the AADvance Troubleshooting Manual (ICSTT-RM406).
- Low-Failure Rate Component – As a passive component, the ICS Triplex T9901 has an extremely low random hardware failure probability, contributing negligibly to the overall PFDavg (Probability of Failure on Demand) calculation for the safety loop.
- Hazardous Location Suitability – The fuse is certified for installation in ATEX Zone 2, IECEx Zone 2, and NEC Class I Division 2 environments, provided it is housed within the required IP54 enclosure and replaced only under proper work permit conditions.
- UL 248-14 – Recognized component certification for low-voltage fuses, verifying the ICS Triplex T9901 meets North American safety standards for overcurrent protection up to 125V.
- RoHS 2011/65/EU – Lead-free and compliant with the Restriction of Hazardous Substances directive, allowing the ICS Triplex T9901 to be sold and used in European Union markets.
- ATEX & IECEx (System Level) – While not an individually marked Ex component, the ICS Triplex T9901 is listed as a spare part in the AADvance system certificate (DEMKO 11 ATEX 1129711X / IECEx UL 12.0032X) for use in Zone 2 gas hazardous areas.
- TÜV Rheinland Functional Safety – The AADvance platform, including the use of ICS Triplex T9901 in termination assemblies, is TÜV-certified for IEC 61508 SIL 2 and SIL 3 applications, as documented in the AADvance Release 2.011 certification.
- Emergency Shutdown Systems (ESD) – The ICS Triplex T9901 protects input channels reading critical process transmitters (pressure, temperature, flow) in oil & gas platforms and refineries, ensuring that a single field loop fault does not compromise the entire safety function.
- Fire & Gas (F&G) Detection Systems – Used in AADvance-based F&G panels, the 50mA fuse safeguards combustible gas detectors, flame scanners, and manual call points, maintaining SIL 3 integrity even in harsh indoor/outdoor environments.
- Burner Management Systems (BMS) – In boiler and furnace control, the ICS Triplex T9901 provides overcurrent protection for flame relay inputs and limit switch circuits, helping prevent nuisance shutdowns caused by transient inrush currents during burner light-off.
- High-Availability Process Control – For critical processes requiring 1oo2D or 2oo3D redundancy, each redundant leg’s input channel uses its own ICS Triplex T9901. If one fuse blows, the other redundant channel(s) continue operation while maintenance replaces the fuse online (in hot-swappable dual/TMR configurations).