Technical specifications for RH924ZJ

  • Manufacturer:
    Invensys
  • Part Number:
    RH924ZJ
  • Product Family:
    Foxboro
  • Product Type:
    Port 1 Fieldbus Baseplate Terminator/Splitter
  • Stock:
    1
  • Accessory type:
    Fieldbus Baseplate Terminator/Splitter
  • Compatible baseplate:
    Standard FCP280 baseplates only
  • Compatible port:
    Fieldbus port 1
  • Fieldbus routing:
    Splits the A and B Module Fieldbus signals into separate cables
  • Cable arrangement:
    Supports optional redundant Fieldbus cable paths
  • Interconnection:
    Connects documented FCP280 and 200 Series baseplate Fieldbus cables
  • Termination function:
    Terminates both Module Fieldbus and optional time-strobe signals
  • Installation restriction:
    Not for the dual-cable FCP280 baseplate
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Port Assignment Signal Paths Service Checks Application
  • Dedicated to FCP280 fieldbus port 1
  • Separates redundant A and B fieldbus paths
  • Provides documented fieldbus and optional time-strobe termination

RH924ZJ is the port 1 terminator/splitter for a standard FCP280 baseplate fieldbus connection.

Use it where redundant A/B fieldbus paths must leave the baseplate as separate cables and the port requires proper termination.

Before replacement, label both paths, verify the port number and record any optional time-strobe connections.

Availability, condition, price, and shipping time for RH924ZJ are confirmed during quotation.

Foxboro RH924ZJ Port 1 Fieldbus Baseplate Terminator/Splitter Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Designed for FCP280 fieldbus port 1
  • Must remain on the documented baseplate port
  • Cannot be moved blindly to another port
  • Separates A and B module-fieldbus paths
  • Terminates the fieldbus at the baseplate
  • Carries documented optional time-strobe connections
  • Label A and B cables before removal
  • Inspect connector seating and shielding
  • Verify termination and communication diagnostics
  • Redundant A/B fieldbus distribution from FCP280 port 1
  • Fieldbus termination at the first processor-baseplate connection
  • Optional time-strobe distribution in supported FCP280 installations
Description
RH924ZJ terminates FCP280 fieldbus port 1 while separating the redundant A and B module-fieldbus paths into individual cables.

It also participates in the documented optional time-strobe connection at the standard baseplate.

Port identity, fieldbus topology, termination position and time-strobe wiring must be preserved during replacement.
Alternative Names
RH924ZJ RH 924ZJ Foxboro RH924ZJ Invensys RH924ZJ Invensys Foxboro RH924ZJ FCP280 RH924ZJ
Technical notes
Foxboro RH924ZJ is the FCP280 port 1 terminator/splitter. Preserve the exact port, A/B cable assignment, termination and optional time-strobe wiring during replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How can I avoid selecting the wrong FCP280 fieldbus interface?
Use RH924ZJ only for the documented FCP280 fieldbus port 1 arrangement. If another port is required, verify whether the RH928CV any-port interface is specified, and confirm the baseplate, A/B paths, connectors and fieldbus type before ordering.
What does Foxboro RH924ZJ do with the A and B fieldbus paths?
It separates the redundant A and B signals from the baseplate into individual cables while providing the required fieldbus termination.
Does Foxboro RH924ZJ replace a fieldbus cable?
No. RH924ZJ is the terminator/splitter at the baseplate; the correct outgoing fieldbus cables remain separate items.
Can Foxboro RH924ZJ be moved from a standard to a dual-cable baseplate?
Do not assume compatibility. Confirm the exact baseplate architecture and accessory diagram because dual-cable baseplates use a different topology.
Why can one path fail after replacing Foxboro RH924ZJ?
Check A/B cable assignment, connector seating, shielding, terminator integrity, fieldbus rate and database path before condemning the accessory.
What should be recorded before removing Foxboro RH924ZJ?
Record the port 1 location, A/B cable labels, termination, optional time-strobe wiring, neighboring accessories and communication diagnostics.
How should Foxboro RH924ZJ be validated after installation?
Confirm both A and B fieldbus paths, termination quality, time-strobe operation where used and recovery after a controlled single-path interruption.