    Apter Power reviews MXQ8-10P-M9BL piping and sensor configuration before quotation.

MXQ8-10P-M9BL

/ 4.9
1001 reviews | Need a Specific Revision?
SMC MXQ8-10P-M9BL is an MXQ air slide table with 8 mm bore, 10 mm stroke, axial piping and an in-line 3 m two-wire solid-state auto-switch configuration.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for MXQ8-10P-M9BL
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for MXQ8-10P-M9BL

  • Manufacturer:
    SMC
  • Part Number:
    MXQ8-10P-M9BL
  • Product Family:
    SMC
  • Product Type:
    MXQ Air Slide Table
  • Stock:
    1
  • Series:
    MXQ
  • Bore Size:
    8 mm
  • Stroke:
    10 mm
  • Piping:
    Axial
  • Auto Switch:
    M9BL solid-state
  • Switch Wiring:
    2-wire
  • Switch Entry:
    In-line
  • Lead Wire Length:
    3 m
  • Switch Voltage:
    24 VDC (10–28 VDC)
  • Estimated shipping dimensions:
    5.3x3.8x2.3cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Sensor Orientation Pneumatic Layout Guided Installation Product Applications

Features:

  • Integrated guide table: The MXQ body combines pneumatic travel with a guided work surface.
  • Axial piping: The P configuration routes pneumatic connections from the designated axial side.
  • In-line sensing lead: M9BL keeps the 3 m two-wire cable aligned with the switch body.
The complete code identifies a 10 mm-stroke MXQ8 slide plus its piping and sensing configuration, not only the actuator size.

Its system role is short guided pneumatic positioning with a solid-state signal available to the machine control.

A replacement should preserve port access, switch orientation and cable route around the moving equipment.

Apter Power can support enquiries for the SMC MXQ8-10P-M9BL MXQ Air Slide Table after the axial-piping and in-line switch configuration are confirmed.
SMC MXQ8-10P-M9BL MXQ Air Slide Table Manuals,Datasheets,Link
Important Notice: No qualified exact-model English PDF is attached. Use the complete product model in every document request.
  • In-line cable exit: M9BL routes the lead in line with the sensor body rather than perpendicular to it.
  • Two-wire circuit: Match the input circuit to the documented two-wire solid-state switch arrangement.
  • Lead reach: Route the 3 m cable without placing tension on the switch or moving table.
  • Clearance proof: Check tooling and guards across the full stroke before fixing the cable path.
  • Axial ports: Keep fitting access clear at the piping direction defined by the P code.
  • Tube support: Prevent tubing loads from twisting the compact slide body.
  • Flow adjustment: Set controlled travel before allowing the table to impact either stroke end.
  • Clean supply: Use the machine pneumatic preparation required for the MXQ circuit.
  • Mounting surface: Use a flat base so the integrated guide is not distorted during fastening.
  • Tooling load: Keep external moments within the selected MXQ8 application limits.
  • Stroke clearance: Reserve space for the complete 10 mm table movement and attached workpiece.
  • Position acceptance: Test both switch states and mechanical end positions before production cycling.
  • Short pick-and-place: Provides compact guided movement between two nearby machine positions.
  • Part alignment: Moves a small fixture or workpiece while the table constrains motion.
  • Sensor-confirmed transfer: Supplies a solid-state position indication to the control system.
  • Space-limited tooling: Fits mechanisms that benefit from an integrated slide-and-guide body.
Description
Compact guided motion and axial port access define MXQ8-10P-M9BL, an 8 mm-bore air slide table configured for a 10 mm working stroke.

The in-line M9BL switch arrangement on MXQ8-10P-M9BL provides solid-state position sensing through a two-wire, 3 m lead, keeping the cable exit aligned with the selected sensor body.

Because MXQ8-10P-M9BL combines the P piping form and the M9BL switch code, maintenance purchasing should preserve the pneumatic and sensing suffixes rather than matching only the MXQ8-10 body.
Alternative Names
MXQ810PM9BL MXQ8 10P M9BL
Technical notes
MXQ8-10P-M9BL uses the in-line M9BL two-wire solid-state switch configuration. Replacing it with the perpendicular M9BVL version changes cable exit geometry even though the slide body is similar. Confirm sensor clearance and moving-cable routing before installation, and do not force the lead against surrounding machine tooling.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
The cable on MXQ8-10P-M9BL conflicts with a nearby guard. Can the M9BVL switch be fitted without reviewing the layout?
Do not treat it as a cable-only change. M9BVL uses a perpendicular entry, so verify sensor mounting, guard clearance and lead movement before substitution.
MXQ8-10P-M9BL reaches both ends but the controller never sees one position. Where should diagnosis start?
Separate pneumatic travel from sensing by checking the M9BL switch indication and two-wire input circuit at the failed end before altering flow controls.
Can a standard MXQ8-10 slide replace MXQ8-10P-M9BL during a line stop?
Only if the axial piping and complete M9BL sensing arrangement are preserved or an approved redesign is made. The base stroke code alone is insufficient.
MXQ8-10P-M9BL moves sharply after maintenance. Should the switch position be adjusted first?
No. Stabilize the pneumatic flow and confirm unrestricted tubing before changing the position-sensing setup.
A new fixture is added to MXQ8-10P-M9BL and the table begins binding. What decision should follow?
Remove the added load and inspect mounting flatness plus external moment before cycling again; sensor adjustment will not correct guide distortion.
What should receiving inspect on MXQ8-10P-M9BL before it enters spare stock?
Match the full model, then confirm the P piping form, in-line M9BL sensor code and 3 m lead so the perpendicular variant is not mixed into inventory.