Technical specifications for 3481S2

  • Manufacturer:
    Invensys
  • Part Number:
    3481S2
  • Product Family:
    Triconex
  • Product Type:
    Analog Output Module
  • Stock:
    1
  • Output points:
    4
  • Output signal:
    Current loop
  • Loop power:
    Redundant 24 VDC
  • Internal channels:
    A / B / C selector logic
  • Conversion:
    DAC per channel path
  • Feedback:
    Current loopback
  • Standard baseplate:
    2481S2
  • HART baseplate:
    2483S2
  • Hazardous HART baseplate:
    2483AS2
  • HART multiplexer:
    Triconex 4850
  • Multiplexer part:
    1600106-001
  • Hazardous ETP:
    9863-610F
  • Hazardous ETP terminals:
    8 points, 4 used by module
  • Unused output rule:
    Short active unused points
  • Protective earth:
    Required at hazardous termination
  • Operating temperature:
    0 to 60 °C
  • Storage temperature:
    -40 to 85 °C
  • Humidity:
    5 to 95%, non-condensing
  • System architecture:
    Triple Modular Redundant
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Monitoring & Control Compatibility & Interoperability Compliance

Features:

  • Provides four controlled analog output channels.
  • Accepts redundant 24 VDC loop-power sources through compatible baseplates.
  • Supports HART multiplexing with the designated 2483-series baseplates.
The 3481S2 is the four-point analog-output member used in standard and HART Tri-GP assemblies.

Triplicated selector logic drives each channel while current loopback supports controller diagnostics.

Baseplate identity, loop supply, load resistance, HART wiring and unused-point jumpers must be verified.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Triconex 3481S2:Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Commands valve positioners and other 4–20 mA final elements.
  • Provides HART maintenance access through the 4850 multiplexer arrangement.
  • Feeds hazardous-location isolators from the approved energy-limiting termination assembly.
  • Each output uses selector logic and current loopback to supervise the commanded signal.
  • Four independent points serve separate current-loop final elements.
  • The controller reports module or channel abnormalities through the Tri-GP diagnostic path.
  • The direct 2481S2 baseplate supports the standard four-point output arrangement.
  • HART operation uses 2483S2 or 2483AS2 with the Triconex 4850 multiplexer.
  • The hazardous-location 9863-610F panel accepts four active outputs even though it provides eight terminal positions.
  • Hazardous-location assemblies use the approved baseplate, isolators and energy-limiting termination design.
  • ATEX installations require the documented intrinsic-safety isolators and wiring practice.
  • Certification applies to the complete approved assembly rather than the output module alone.
Description
Triconex 3481S2 provides four current-output channels for final elements and analog interfaces. Each point receives triplicated command paths through selector logic and a dedicated digital-to-analog converter arrangement. Four current-loop outputs use A, B and C channel logic, individual conversion paths and current feedback to support voted analog control.

The module can be used with the 2481S2 direct baseplate, 2483S2 HART baseplate or the corresponding hazardous-location assemblies. HART versions add the Triconex 4850 multiplexer and filtered communication path without changing the four active output count. Standard and HART-capable baseplates extend the same module into conventional or asset-management loops while retaining redundant 24 VDC loop power.

Preserve redundant 24 VDC loop power, correct load polarity and the requirement to short unused active output positions. The HART baseplates are limited to 3481S2; fitting another module can damage baseplate components. Hazardous-location termination adds protective-earth and unused-point requirements that must be reflected in cabinet construction and commissioning records.
Alternative Names
3481S2 Triconex 3481S2 3481 S2 3481-S2 Tricon 3481S2 Schneider Electric Triconex 3481S2 3481S2 Analog Output Module 3481S2 Four-Channel Current Output Module
Technical notes
2483S2 and 2483AS2 HART baseplates are approved only for 3481S2; installing another output module can damage the baseplate.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which signal or interface value should be checked first for 3481S2?
Four analog outputs and compatibility with 2481/2483 baseplates identify the 3481S2 model.
How is 3481S2 matched to the installed rack or termination path?
Confirm the direct, HART or hazardous-location baseplate and any Triconex 4850 multiplexer before ordering.
What field application makes practical use of 3481S2?
It drives current-loop final elements and can preserve HART maintenance communication.
How is an available-condition offer for 3481S2 established?
Apter Power can verify exact hardware labels and provide condition, quantity and delivery information.
Which engineering comparison reduces replacement risk for 3481S2?
Maintain redundant loop power and polarity, short unused active outputs and calibrate every connected loop.
What documentation is useful when requesting pricing for 3481S2?
Send the module, baseplate and multiplexer labels, load list, HART requirement, quantity and destination.