National Instruments PCI-5122 is a two-channel 14-bit PCI digitizer that samples analog waveforms at 100 MS/s and transfers the acquired records to a host computer.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for PCI-5122
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for PCI-5122

  • Manufacturer:
    NATIONAL INSTRUMENTS
  • Part Number:
    PCI-5122
  • Product Family:
    NATIONAL INSTRUMENTS
  • Product Type:
    Two-Channel 100 MHz PCI Digitizer
  • Stock:
    1
  • Vertical resolution:
    14 bits
  • Real-time sample rate:
    100 MS/s
  • Random interleaved sampling:
    Up to 2 GS/s
  • Input impedance:
    50 ohm or 1 megohm
  • Input coupling:
    AC or DC
  • Input ranges:
    0.2 to 20 V peak-to-peak depending impedance
  • Standard onboard memory:
    8 MB per channel
  • Available memory options:
    32 MB or 256 MB per channel
  • Driver:
    NI-SCOPE
  • External calibration interval:
    2 years
  • Warm-up time:
    15 minutes
  • Typical total power:
    17.9 W
  • Weight:
    0.455 kg
  • Estimated shipping dimensions:
    35.5x2x11.3cm
  • Tariff Code:
    9030849000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Analog Inputs Sampling & Memory Trigger & Timing Host Integration

Features:

  • Digitizes two analog channels simultaneously at up to 100 MS/s with 14-bit resolution.
  • Combines 100 MHz bandwidth with selectable impedance, coupling, and input ranges.
  • Stores waveform records in onboard channel memory before PCI transfer to the host.
National Instruments PCI-5122 converts two front-panel analog signals into time-aligned digital records for computer-based measurements.

The input path conditions impedance, coupling, range, and bandwidth before the two converters sample the waveforms.

Trigger, clock, memory, and PCI-transfer functions determine when a record starts, how long it is retained, and when it reaches the host.

The National Instruments PCI-5122 Two-Channel 100 MHz PCI Digitizer may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
National Instruments PCI-5122 Two-Channel 100 MHz PCI Digitizer Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Front-end signal conditioning

  • Channels: Two BNC inputs are sampled by separate converters at the same time.
  • Termination: The front end selects 50 ohm or 1 megohm input impedance.
  • Coupling: AC or DC coupling is applied before analog-to-digital conversion.
  • Range: Selectable full-scale ranges match the converter to the connected waveform.

Record acquisition path

  • Conversion: Fourteen-bit samples are produced at real-time rates up to 100 MS/s.
  • Bandwidth: The analog path supports signals within a 100 MHz bandwidth.
  • Memory: Each channel writes acquired samples to its allocated onboard memory.
  • Transfer: Completed records move from channel memory to the host through the PCI bus.

Acquisition synchronization

  • Trigger input: Trigger circuitry starts an acquisition when the configured source meets its condition.
  • Reference clock: Clock connectors allow supported timing relationships with external equipment.
  • Multi-device timing: NI-TClk coordinates supported NI digitizers when channels span more than one device.
  • Rearm: Record and trigger settings determine how the device proceeds to the next acquisition.

PCI measurement workflow

  • Driver: NI-SCOPE supplies the programming interface for device configuration and waveform transfer.
  • Configuration: The host sets ranges, coupling, sample rate, record length, and trigger conditions.
  • Calibration: Self-calibration corrects gain, offset, frequency-response, trigger, and timing errors.
  • Cooling: Active airflow across the full-length PCI card is required inside the host chassis.
Description
National Instruments PCI-5122 is a two-channel, 14-bit waveform digitizer for a host computer's PCI bus. Each analog input is sampled at as much as 100 MS/s across a 100 MHz bandwidth, and the resulting records are transferred to measurement software for display and analysis.

Both input channels on National Instruments PCI-5122 are sampled simultaneously rather than through one shared converter. Selectable 50 ohm or 1 megohm input paths, AC or DC coupling, and multiple voltage ranges adapt the front end to the connected signal before conversion.

Acquired samples on National Instruments PCI-5122 enter channel memory before the PCI interface moves them to the host. The installed memory option therefore sets the record depth available per channel without changing the 100 MS/s real-time sampling limit.

Trigger and timing connectors on National Instruments PCI-5122 coordinate acquisition start and clock relationships with the measured event or another supported digitizer. NI-SCOPE supplies the software interface used to configure channels, triggering, records, and self-calibration from the host application.
Alternative Names
PCI5122 PCI 5122 NI PCI-5122 National Instruments PCI 5122 PCI-5122 Digitizer PCI5122 Oscilloscope PCI-5I22 PC1-5122
Technical notes
PCI-5122 is the full-length PCI model; PXI-5122 and PXIe-5122 have different mechanics and must not be used for its dimensions or slot requirements.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What does National Instruments PCI-5122 measure?
National Instruments PCI-5122 converts two analog waveforms into 14-bit digital records for host-based time- and frequency-domain analysis.
Are both channels on National Instruments PCI-5122 sampled at the same time?
Yes. National Instruments PCI-5122 uses two simultaneously sampled input channels, preserving their relative timing within the acquisition.
Which input termination should be selected on National Instruments PCI-5122?
Select the 50 ohm or 1 megohm path on National Instruments PCI-5122 to match the source and cable system before choosing the voltage range.
How does onboard memory affect National Instruments PCI-5122?
The installed memory option determines how many samples National Instruments PCI-5122 can retain per channel before records are transferred across PCI.
Which software controls National Instruments PCI-5122?
National Instruments PCI-5122 is configured through the NI-SCOPE driver, which exposes channel, trigger, record, timing, and calibration functions.
Can a PXIe-5122 mechanical drawing be used for National Instruments PCI-5122?
No. National Instruments PCI-5122 is a full-length PCI card and has different dimensions and slot requirements from PXI or PXI Express versions.