- Separate the 150 A maximum output from the 99.7 A continuous limit at 4 kHz
- Budget the 115 A rated DC input across the complete common-bus axis group
- Remove the documented 965 W loss through the required forced-air path
HMS01.1N-W0150-A-07-NNNN is the R911297164 IndraDrive M W0150 single-axis inverter power section.
At 4 kHz it provides 99.7 A continuously and up to 150 A for transient demand. The power section draws 115 A rated current from the common DC bus.
Verify simultaneous axis loading, regeneration, 965 W cabinet loss, forced ventilation, X6 wiring and the separately selected control section and firmware.
Availability, condition, price, and shipping time for HMS01.1N-W0150-A-07-NNNN are confirmed during quotation.
Bosch Rexroth HMS01.1N-W0150-A-07-NNNN IndraDrive M Single-Axis Inverter Manuals, Product Family, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Allow 115 A rated DC input when sizing the HMV or compatible converter source
- Include simultaneous acceleration and regenerated energy from every connected axis
- Recheck bus conductors and protection before replacing a smaller HMS power section
- Use 99.7 A as the documented continuous output at 4 kHz
- At 8 kHz, distinguish the 150 A maximum from the 67.5 A continuous limit
- At 16 kHz, recalculate the axis using 106 A maximum and 36.8 A continuous output
- Remove 965 W of documented power loss at continuous-current operation
- Keep the forced-air inlet and outlet clear of filters, wiring and recirculated hot air
- Include the separate control section and motor-brake load in the 24 V supply budget
- Compare the documented 55 kW profile at 400 V with the installed standard motor
- For 460 V systems, verify the documented 55.2 kW continuous profile and overload cycle
- Use switching-frequency-specific current limits for repeated acceleration and sustained production duty