MICROLOGIC 6.0 E
MICROLOGIC 6.0 E
MICROLOGIC 6.0 E
MICROLOGIC 6.0 E
MICROLOGIC 6.0 E
MICROLOGIC 6.0 E
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>
  • Lifecycle status

    Active / Available from OEM
    Apter supplies Micrologic 6.0 E 47603 with catalog and application verification.

Micrologic 6.0 E 47603

/ 4.9
1001 reviews | Need a Specific Revision?
Schneider Electric Micrologic 6.0 E control unit, catalog 47603, for MasterPact NT/NW LSIG protection and energy metering.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for Micrologic 6.0 E 47603
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for Micrologic 6.0 E 47603

  • Manufacturer:
    Schneider Electric
  • Part Number:
    Micrologic 6.0 E 47603
  • Product Family:
    Schneider Electric
  • Product Type:
    MasterPact NT/NW LSIG Control Unit
  • Stock:
    1
  • Catalog reference:
    47603
  • Breaker family:
    MasterPact NT/NW
  • Protection functions:
    LSIG
  • Measurement:
    Energy meter
  • Control unit:
    Micrologic 6.0 E
  • Weight:
    0.2 kg
  • Estimated shipping dimensions:
    5.8x7.2x19.8cm
  • Tariff Code:
    8538900000
  • Country of origin:
    France
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals LSIG Protection Energy Metering Breaker Scope Product Applications

Features:

  • Protection scope: The control unit combines long-time, short-time, instantaneous, and ground-fault protection.
  • Energy visibility: The E version adds energy-measurement capability to the breaker protection platform.
  • Breaker integration: Micrologic 6.0 E 47603 is associated with compatible MasterPact NT and NW circuit breakers.
Micrologic 6.0 E 47603 places selective protection and electrical-energy information in the same MasterPact control unit. This lets one breaker location contribute both protective decisions and operating data.

The unit is neither a standalone meter nor a complete circuit breaker. It forms the electronic protection and measurement layer inside the compatible breaker assembly, working with the installed sensing and tripping hardware.

Selection should follow the breaker's engineered protection scheme. The catalog reference, breaker platform, sensor arrangement, and approved coordination settings together establish whether this is the correct control unit.

Apter Power can assist with official catalog review, quotation, and sourcing coordination for Micrologic 6.0 E 47603.
Schneider Electric Micrologic 6.0 E 47603 MasterPact NT/NW LSIG Control Unit Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • L provides long-time overload protection
  • S and I provide short-time and instantaneous protection
  • G provides ground-fault protection
  • The E version includes energy-meter measurement
  • Confirm measurement setup after installation
  • Retain meter and protection commissioning records together
  • Official reference applies to compatible MasterPact NT/NW breakers
  • Match the sensor and breaker frame before replacement
  • Transfer settings only through the approved procedure
  • Selective low-voltage distribution protection
  • MasterPact NT/NW feeders requiring ground-fault protection
  • Circuit-breaker protection with integrated energy measurement
Description
Micrologic 6.0 E 47603 is Schneider Electric catalog 47603, a Micrologic 6.0 E control unit for MasterPact NT and NW circuit breakers. Official product information identifies selective and earth-fault LSIG protection together with energy-meter measurement functions.

Micrologic 6.0 E 47603 must be matched to the compatible breaker frame, sensor rating, protection settings, trip-unit connector, and commissioning records. Replacement planning should preserve the approved L, S, I, and G settings and validate metering and trip behavior under the site's electrical-safety procedure.
Alternative Names
Schneider 47603 Micrologic 6.0E LSIG Control Unit
Technical notes
Micrologic 6.0 E 47603 is the MasterPact NT/NW LSIG and energy-metering reference, not a generic Micrologic 6.0 E description. Verify breaker compatibility, sensor rating, protection settings, connector condition, and commissioning records before replacement. Only qualified personnel should perform setting transfer, secondary injection, and trip-chain validation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can Micrologic 6.0 E 47603 inherit settings from another Micrologic trip unit without review?
No. The LSIG protection and energy-meter setup must match the installed MasterPact NT/NW breaker, sensor rating, and approved coordination study before settings are transferred.
Why must the G function be commissioned separately on Micrologic 6.0 E 47603?
Ground-fault protection depends on the installed sensor and circuit arrangement, not only the presence of the G label. Prove pickup and trip behavior under the site's electrical-safety procedure.
When should replacement of Micrologic 6.0 E 47603 stop at the breaker?
Stop if breaker family, frame, sensor rating, connector, or LSIG setting record does not match catalog 47603. Resolve the mismatch before energizing the breaker.
How should energy measurement be validated after fitting Micrologic 6.0 E 47603?
Configure the E-version metering inputs and compare displayed values with an approved reference under known load. Correct sensor or setup errors before using the measurements for operations.
Which protection record must remain linked to Micrologic 6.0 E 47603?
Keep the approved L, S, I, and G settings with the breaker frame, sensor rating, and commissioning results. That record is the baseline for later maintenance and fault review.
Before returning Micrologic 6.0 E 47603 to service, what must the trip test establish?
The test must prove the intended LSIG functions and breaker operation for the installed arrangement. Do not release the feeder if protection or metering results differ from the approved settings.